F99 Fusion Inertial Measurement Unit IMU360D-F99-B20
Commissioning
201
8-0
5
13
4.2
Identification characters for system environment
For identification of the sensor in his system environment the sensor provides some characters
you can parameterize during commissioning.
The following table contains the default values of Interface configuration and J1939 name.
They can be defined in the parameters "J1939 Interface" and "J1939 -Name" as listed in
chapter "Parameter Table".
J1939 Name
Default
Range
Comment
Arbitrary Address
Capable
0
0, 1 (1 bit)
Specifies if the ECU can
choose another source
address if it loses the
address claim procedure
Industry Group
0
0 ... 7 (3 bit)
Specifies the industry. (e.g.
off-highway)
Vehicle System
Instance
0
0
…
15 (4 bit)
Identifies a particular
occurrence of vehicle
system. (e.g. trailer #3)
Vehicle System
0
0
…
127 (7 bit)
Identifies vehicle system
(e.g. trailer)
Reserved
1
0, 1 (1 bit)
Fix bit for internal use only
Function
0
0
…
255 (8 bit)
Identifies the function (e.g.
ABS)
Function Instance
0
0
…
31 (5 bit)
Identifies the function
instance (e.g. ABS #1)
ECU Instance
0
0
…
7 (3 bit)
Identifies the ECU instance
inside of the function field.
Manufacturer Code
632
0
…
2047 (11 bit)
632: Fuchs
manufacturer code
Identity Number
Unique serial
number (fix)
0
…
2097151 (21 bit) Product serial number
Table 4.2