Commands
20
12-
12
73
You must select the tag type '50' (ICC-...) beforehand in order to read out this
code. If a "read only code" command is executed when the tag type '50' (IDC-...-
1K) is set, the 4-byte read only code for this tag is issued.
Enhanced buffered write read only code (EX --> 24h)
The R/W head constantly attempts to write a read only code. After each
successful write, the response is sent and the system waits until a new tag is
within the detection range. The command then starts again from the beginning.
For more information see chapter 7.3.11.
Extended commands for type IDC-... and IUC
…
tags
Type IDC-...-1K tags can be programmed to read 24-bit information (so-called
special read only code)
very quickly. This is useful for detecting containers in
automated warehouses.
To write the
special read only code
use the commands
SP
and
EP
; to read it
out, use the commands
SS
and
ES
.
Master -> Slave
Address
Bit no.
CH1
CH2*
15
8
7
0
RWw n
RWw n+8
<FixLen>
0 0
1 0
0 1
0
0
RWw n+1
RWw n+9
<FixType> (low byte)
<FixType> (high byte)
RWw n+2
RWw n+A
<Data>
<Data> (high byte)
...
...
<Data>
<Data>
RWw
n+1+N
1)
RWw
n+9+N
1)
<Data> (low byte)
<Data>
Slave -> Master
Address
Bit no.
CH1
CH2*
15
8
7
0
RWr n
RWr n+8
<FixLen>
0 0
1 0
0 1
0
0
RWr n+1
RWr n+9
<ReplyCounter>
<Status>
n:
Address in master module, specified by the assignment of the stations
*:
If 2 channels are used
1)
:
N =<FixLen>/2 rounded up
Length of the
special read only code
:
■
Tag of the type IDC-...-1K:
48 bit
■
Tag of the type IUC:
96 ... 240 bit