20
12-
12
50
Commands
The configuration store (CS) command allows you to store the last command sent
to the R/W head in the non-volatile memory of the IDENTControl Compact. The
R/W head executes the command automatically again if the power supply is
interrupted or the IDENTControl Compact is reset.
<Mode>='1' activates the mode.
<Mode>='0' deactivates the mode.
Configuration store
is deactivated by default.
Reset (RS --> 16h)
The device resets the hardware and then restarts.
Reset to default (RD --> B4h)
This command stops all running commands. The conrol unit is reset to the factory
settings. The changes take effect after a restart.
Set multiplex mode (MM --> 9Bh)
Master -> Slave
Address
Bit no.
CH1
15
8
7
0
RWw n
0 0
0 1
0 1
1
0
RWw n+1
-
n:
Address in master module, specified by the assignment of the stations
*:
2 channel mode
Master -> Slave
Address
Bit no.
CH1
CH2*
15
8
7
0
RWw n
RWw n+8
1 0
1 1
0 1
0
0
RWw n+1
RWw n+9
-
n:
Address in master module, specified by the assignment of the stations
*:
2 channel mode
Master -> Slave
Adresse
Bit Nr.
CH1
CH2*
15
8
7
0
RWw n
RWw n+8
1 0
0 1
1 0
1
1
RWw n+1
RWw n+9
-
<Mode>