IO-Link Parameterization
2
0
2
0
-0
9
29
The following table shows the respective switching characteristics for each combination. It is
necessaryto distinguish between the position sector (see previous figure) that is changed to
the next position sector and the status of the switching channel has shortly before the sector
change.
If the position sector is changed from sector 4 (SP1 hysteresis area) to sector 3 (= inner win-
dow area) and the SSC1 switching channel is about to switch to "high," SSC1 will switch its
contents to "low" if sector 4 exceeds sector 3.
You can set the desired measuring range as "high active" or "low active" using the "SSC1 Con-
fig Logic" (0x41 Sub 1) parameter.
These switching characteristics apply to the singlepoint mode if the "SSC 1 Config Mode"
(0x41 Sub 2) parameter is set to "Single point."
6.7
Config - Auxiliary Measurement
Configuration - Auxiliary Measurement
The "Config - Auxiliary Measurement" parameter is used to set whether an additional mea-
sured value is transferred in the cyclical process data word. For the ENA***TL-**IO** product
group, this additional measured value is the ambient temperature of the device.
MDC1
—
Position
Switching Charac-
teristics of SSC1
Switching Signal 1
From "Position Sector"
SSC1 Value
To "Position Sector"
1
high
2
high
–
> high
2
high
3
high
–
> low
2
low
3
low
–
> low
3
low
4
low
–
> low
4
low
1
low
–
> high
4
high
1
high
–
> high
1
high
4
high
–
> high
4
high
3
high
–
> low
4
low
3
low
–
> low
3
low
2
low
–
> low
2
low
1
low
–
> high
2
high
1
high
–
> high
Table 6.1
Index
Sub
Parameter
Access
Data Type
Length
101 (0x65)
–
Config - Auxiliary Measurement
rw
UInteger
8 bits