Commissioning
4
Commissioning
4.1
Commissioning with IO-Link on a Control Panel
(Online Parameterization)
To activate the absolute rotary encoder via IO-Link using a control panel, proceed as follows:
1.
Check the connection between the absolute rotary encoder and the IO-Link master.
2.
Set the status to "IO-Link" on the corresponding port on the IO-Link master to which the
absolute rotary encoder is connected.
3.
Once communication has been successfully established, the green operating indicator LED on
the absolute rotary encoder will flash briefly in one-second intervals.
The absolute rotary encoder can now either be parameterized using the IO-Link configura-
tion tool or diagnosed using the modulated application. The device sends the binary switch-
ing information and the position value as process data.
4.2
Commissioning with IO-Link via FTD Framework Program
(Offline Parameterization)
IO-Link Offline Parameterization Tool
An IODD (IO-Link Device Description) file is available to download for parameterization of the
absolute rotary encoder via IO-Link and diagnosis. See the product page for the relevant
ENA***TL-**IO** absolute rotary encoder online at
www.pepperl-fuchs.com
or use the
IODDfinder at https://iodfinder.io-link/com/.
For offline parameterization, IO-Link devices are already configured before mounting. To do
this, you can use the Fuchs IO-Link USB master.
The software components required in each case are summarized in the "IO-Link Offline Param-
eterization Tool" software package in their most current versions. The software package can be
found online at www.pepperl-fuchs.com along with the corresponding documentation regard-
ing installation and use.
If you use the "IO-Link Offline Parameterization Tool" software package, have active Internet
access, and have connected your device via the Fuchs IO-Link USB master, you can
integrate the IODD directly into the IO-Link Offline Parameterization Tool via the "IODD DTM
Configurator."
Note
The device description file (IODD) required for integration in an IO-Link system and for
parameterization and diagnostics is available online. Visit www.pepperl-fuchs.com and
navigate to the relevant product page for the ENA***TL-**IO**.
Note
A 5-pin M12 cordset is needed to connect the absolute rotary encoder to the Fuchs
IO-Link master. Visit
www.pepperl-fuchs.com
and click on the product page for the relevant
absolute rotary encoder to find suitable cordsets.