44

system specifications

System Dimensions: 

See Pages 10 & 11

Shipping Weight ( lbs.): 

LPS - 5

Operating Temp. Range: 

40° F - 120° F

Supply Pressure Range: 

* 5 -120 PSI max.

Supply Requirements: 

Clean Air or Inert Gas

Safe Press. (CI/CII): 

0.25" / 1.0"

Safe Pressure Flowrate: 

** 0.1-3.5 SCFH

System Supply Fitting: 

1/4" Tube Fitting

Enclosure Supply Fitting: 

1/4" Tube Fitting

Enclosure Reference Fitting: 

1/4" Tube Fitting

*  With Enclosure Protection Vent - 120 PSI maximum
  Without Enclosure Protection Vent -  5 PSI maximum

In order to comply with the NFPA 496 standard requiring 
protection against over pressurization of the protected en-
closure, the installer must install one of the following items 
in addition to the enclosure protection system.

a)  Install a Enclosure Protection Vent on the protected 

enclosure.

b)  Install  a  tamper-proof  regulator  upstream  of  the 

enclosure protection system's system supply inlet to 
pre-regulate protective gas supply to 5 PSI max.

In addition, for small, tightly sealed enclosures, or to com-
pensate  for  a  fluctuating  protective  gas  supply,  it  may 
be  necessary  to  pre-regulate  the  protective  gas  supply 
to  a  constant  5  PSI  regardless  of  whether  an  Enclosure  
Protection Vent is installed.  This will reduce the amount of 
"drifting" that can normally occur when maintaining a "Safe" 
pressure inside a protected enclosure.  The pre-regulation 
can  be  accomplished  by  installing  the  TR-10  or  TR-10G 
Tamper-Proof Regulator accessories or equivalent.

Material specifications

Regulator Body: 

zinc w/ Enamel Finish, Brass

Regulator Handle: 

Polycarbonate

Enclosure Pressure Gauge: 

ABS Plastic

Tube Fittings: 

316 SS Forged Body

Tubing: 

316 SS 1/4" .035 Welded

System Nameplates: 

Silkscreened Lexan

®

 & SS

Fastener Hardware: 

zink Plated & Stainless Steel

Mounting Plate: 

316 14 Ga #3 Brush SS

EXP Pressure Switch Body: 

Anodized Cast Alum.

Enclosure Warning Nameplate: 

Silkscreened SS

Recommended spare parts

Qty  Description 

Part # (supercedes)

Enclosure Pressure Indicator-CI 

510023 

Enclosure Pressure Indicator-CII 

513235

Enclosure Pressure Control Regulator 

513653

Installation & Operation Manual 

129-0200

Enclosure Warning Nameplate-CI 

513008

Enclosure Warning Nameplate-CII 

513009

Please call and reference the above part number for 
current spare parts pricing.  Immediate pricing is available 
to all confirmed customers. 

Installation tools & testing Equipment

1/2" chuck drill
Complete set of drill bits
1/2" conduit knockout punch or 0.875" hole saw
Complete set of tubing, conduit bending, instrument fitting 
and electrical craftsman hand tools
0 - 250 scfh flowmeter (connected upstream of the Protection 
System to determine air consumption and flow during set-
up procedure)

General Information

Model 1001a system accessories

optional Enclosure protection Vents

EPV-1-SA-00 

Straight w/ Spark Arrestor

EPV-1-SA-90 

Rt Angle w/ Spark Arrestor

additional Items

SMK-1, -4* 

System Mounting Kit

ILFK-4* 

1/4" In-line Filter Kit

SC-4* 

1/4" x 1/4" straight Connector

EPSK-1 

Class I, Group C - D Pressure Switch

 

Kit

EPSK-1A 

Class I, Group A - D Pressure Switch

 

Kit

EPSK-2 

Class II, Group E - G Pressure Switch Kit

GPSK-1 

Class I, General Purpose Switch Kit

GPSK-2 

Class II, General Purpose Switch Kit

RAH 

Div. 1 Remote Alarm Horn

RAB-1 

Div. 1 Remote Alarm Beacon

RAB-2 

Div. 2 Remote Alarm Beacon

LCK 

L Fitting Conduit Kit

TCK 

T Fitting Conduit Kit

PIAD 

Purgeable Instrument Access Door

TR-10 

Tamper-Proof Regulator

TR-10G* 

Tamper-Proof Regulator w/ Gauge

PR-10 

Precision Regulator

PR-10G 

Precision Regulator w/ Gauge

*  These items are provided as part of the Hoffman Kit.

**  Accessory items are available through Fuchs.  

Please consult the Fuchs Customer Service De-
partment for suitability of items for this assembly before 
purchase.

RSPSupply  -  1-888-532-2706 -  www.RSPSupply.com

http://www.RSPSupply.com/p-6798-Hoffman-A1001YZUMC2-Purging-Pressurization-System-10-CF.aspx

Summary of Contents for 1001A Series

Page 1: ...cessories Supplied with Each Kit Pentair Technical Products 2100 Hoffman Way Anoka Minnesota 55303 PH 763 422 2211 hoffmanonline com Hoffman P N 87571946 Manufactured by 1600 Enterprise Parkway Twinsb...

Page 2: ...subject to change without notice Table of Contents Page 2 System Purpose and Description Purpose System Description Important Notes Page 3 Identifying Your System Defines specific features of the syst...

Page 3: ...ion proof differential pressure switch used to detect loss of safe enclosure pressure LPS Less Pressure Switch SYSTEM TYPE Type Z Reduces the internal enclosure area Division rating from Division 2 to...

Page 4: ...re Warning Nameplate Silkscreened SS Recommended Spare Parts Qty Description Part supercedes 1 Enclosure Pressure Indicator CI 510023 1 Enclosure Pressure Indicator CII 513235 1 Enclosure Pressure Con...

Page 5: ...Calculation 1 The total volume of all pressurized enclosures devices and wireways must be considered 2 All enclosure device and wireway volumes must be calculated without consideration of internally...

Page 6: ...SERVICE VALVE SYSTEM SUPPLY FITTING ENCLOSURE PROTECTION SYSTEM SYSTEM MOUNTING BOLT ENCLOSURE SUPPLY TUBING ENCLOSURE PROTECTION VENT optional PROTECTED ENCLOSURE ENCLOSURE CONNECTION FITTINGS ENCLOS...

Page 7: ...OUTLET OUTLET B TYPICAL MULTIPLE PROTECTED ENCLOSURE CONNECTIONS 1 2 PROTECTIVE GAS SUPPLY HEADER A A D C Connections for Lighter than Air Gases and Vapors HELPFUL HINTS If flammable gases are lighte...

Page 8: ...ions are intended for mounting adjacent to the protected enclosure LH RH TM BM configurations are also suitable for 2 schedule 40 pipe mounting In addition these configurations can be accessorized wit...

Page 9: ...LLED IN LINE FILTER KIT ACCESSORY Provides an 8 5 oz capacity 40 micron protective gas supply filter factory installed on the inlet side of the enclosure pressure control regulator Typical Surface Mou...

Page 10: ...10 10 Mounting Plate Dimensions Model 1001A Face Plate 9 8 9 8 RSPSupply 1 888 532 2706 www RSPSupply com http www RSPSupply com p 6798 Hoffman A1001YZUMC2 Purging Pressurization System 10 CF aspx...

Page 11: ...25 TYP 4 Flange Depth 6 3 375 1 1 0 675 0 5 Universal Flange Footprint Optional Wall Flange Footprint only available from Pepperl Fuchs RSPSupply 1 888 532 2706 www RSPSupply com http www RSPSupply c...

Page 12: ...cted enclosure The length of time required is determined by the customer and can be factory or field engraved All EWNs and ETWs are furnished with an adhesive back but should also be riveted or screwe...

Page 13: ...odel ILFK accessory See photo on page 9 One 1 Similar fitting which will connect the inert gas supply tubing to the inert gas supply header connection point and one 1 lot of 1 4 O D 035 wall thickness...

Page 14: ...closure protection system whenever possible For systems protecting multiple enclosures in series the enclosure reference connection fitting must be placed on the last enclosure in the series see page...

Page 15: ...nections are bolded System Supply Venturi Orifice Inlet Enclosure Pressure Gauge Regulator Sintered Vent Reference Supply Enclosure Reference Bulkhead fitting Enclosure Supply Bulkhead fitting System...

Page 16: ...or 500 3 as required and all relevant plant and local codes Note Do not use seals on conduit used as a protected wireway to supply protective gas to adjacent protected enclosures The same conduit can...

Page 17: ...ocked position upon arrival To adjust regulator pull handle to outward position 1 Close the Enclosure Pressure Control Regulator fully by turning counterclockwise CCW 2 Temporarily connect the inert g...

Page 18: ...ed if utilized 1 Carefully read Start Up Instruction Nameplate on system 2 CheckoperationoftheEnclosureProtectionVent EPV 1 if utilized opening it manually several times see page 17 Helpful Hint 3 Sea...

Page 19: ...osure Remove the orifice cut off the crimped end and ream the tube then recrimp and reinstall the tube to note effect As tube is shortened reamed andrecrimped sensitivitydecreases allowingeasieradjust...

Page 20: ...O THE PRODUCTS IT IS EXPRESSLY AGREED AND UNDERSTOOD THAT P F MAKES NO WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE EXCEPT FOR THE LIMITED WARRANTY SET FORTH HEREIN THERE IS NO OTHE...

Page 21: ...ing to the set up procedure and operating sequence on pages 17 and 18 Replace or tighten stem packing nut as required to prohibit stem packing leakage Carefully disassemble the enclosure protection ve...

Page 22: ...22 22 CUSTOMER NOTES RSPSupply 1 888 532 2706 www RSPSupply com http www RSPSupply com p 6798 Hoffman A1001YZUMC2 Purging Pressurization System 10 CF aspx...

Page 23: ...23 23 CUSTOMER NOTES RSPSupply 1 888 532 2706 www RSPSupply com http www RSPSupply com p 6798 Hoffman A1001YZUMC2 Purging Pressurization System 10 CF aspx...

Page 24: ...omer Project Service Type Features Application SYSTEMS IDENTIFICATION APPLICATION INFORMATION Local Sales Representative NOTES RSPSupply 1 888 532 2706 www RSPSupply com http www RSPSupply com p 6798...

Reviews: