Pepperl+Fuchs 1001A Series Installation & Operation Manual Download Page 2

22

page 13

  pneumatic tubing Requirements

 

Protective Gas Supply Requirements, Pneumatic 
Connection Requirements

page 14

  tubing Installation

 

LH,  RH,  TM,  BM,  WM,  FM  &  PM  Tubing 
Configurations

page 15

  tubing Connection Diagrams

 

LH, RH, TM, BM, WM, FM, & PM Configuration 
Connection Points, Pneumatic Diagram 

page 16

  Conduit Installation

 

Electrical & WPS Style Conduit and Connection 
Parts

page 17

  set-Up procedure

 

Class I & Class II Set-up

page 18

  operating sequence

 

Class I &  Class II Operation

page 19

  troubleshooting procedures

 

Troubleshooting Chart

page 20

  Warranty and liability statement

 

Warranty Notes, General Terms, Limitations 

page 21

  system Maintenance

 

Regular Maintenance, Long-term Maintenance, 
Maintenance Schedule

page 22

  Customer notes

page 24

  systems  Identification  &  application 

Information

Important notes

One (1) permanent file copy and one (1) operations copy of 
this Manual must be studied and retained by the operator of 
this System. User’s Agents are responsible for transferring 
this Manual to the user, prior to start-up.

The contents of this manual have been arranged to allow the 
use of this product as a stand-alone device on equipment 
and  enclosures  supplied  by  the  user  or  its  agents.    The 
Manual’s  parameters  encompass  a  combination  of  both 
National  Fire  Protection  Association  (NFPA)  requirements 
and  Fuchs,  Inc.  requirements.    Fuchs 
therefore acknowledges the use of NFPA 496 as a guideline, 
that we have enhanced certain NFPA requirements and that 
additional information has been compiled to complete this 
document.  The Manual is intended as a complete guide and 
must be considered, unless specifically stated otherwise, 
that all directives contained herein are requirements for safe, 
practical and efficient use of this product.

This System is not intended for use to protect enclosures 
or devices which contain ignitable concentrations of gases 
or vapors.  This exclusion generally applies to process or 
product analyzing systems equipment.

all specifications are subject to change without notice.

table of Contents

page 2

 

system purpose and Description

 

Purpose,  System  Description,  Important 
Notes

page 3

 

Identifying Your system

 

Defines specific features of the system

page 4

 

General Information

 

System & Material Specifications, System Acces-
sories, Spare Parts, Tools & Test Equipment

page 5

 

Enclosure and Device Design

 

Design  Requirements,  Adjacent  Enclosures, 
Device Ventilation, Temperature Limitations

page 6

 

Installation overview

 

Installation Diagram

page 7

 

Getting started

 

Establishing  Connection  Sizes,  Determining 
Enclosure Inlet & Outlet Connection Locations

page 8

 

system Mounting

 

LH,  RH,  TM,  BM  &  WM  Configurations, 
FM & PM Configurations

page 9

 

special Mounting Information

 

ECK, ILFK Connection Diagram, Typical Panel 
Mount Diagram

page 10

  Mounting plate Dimensions

 

Mounting Plate Dimension Diagrams

page 11 

Mounting plate Dimensions (cont.)

 

Mounting Plate Dimension Diagrams

page 12

  Hardware Mounting

 

Optional  Enclosure  Protection  Vent,  Warning 
Nameplates

purpose

Fuchs' Bebco EPS System allows the use of general-
purpose or nonrated electrical or electronic devices, with 
exception to devices which produce excessive heat, utilize 
combustible gas, or expose arcing contacts to the hazardous 
atmosphere,  in  NEMA  (National  Electrical  Manufacturers 
Association) 4 or 12 enclosures in the place of explosion 
proof NEMA 7 enclosures.  Other purposes include heat, 
moisture and dust contamination prevention.

Description

Model  1001A  is  an  enclosure  pressurization  or  purging 
system that operates on a supply of compressed instrument 
air or inert gas.  It regulates and monitors pressure within 
sealed  (protected)  enclosures,  to  prevent  combustible 
dust accumulation or remove and prevent flammable gas 
or  vapor  accumulations.    In  Class  II  areas,  the  system 
maintains  a  “safe”  (1.0")  pressure.    In  Class  I  areas,  the 
system  accomplishes  four  air  exchanges  and  maintains 
a  “safe”  (0.25")  pressure.    These  processes  reduce  the 
hazardous (classified) area rating within the enclosure(s), in  
accordance with the NEC - NFPA 70, Article 500, NFPA 496 
and ISA 12.4

RSPSupply  -  1-888-532-2706 -  www.RSPSupply.com

http://www.RSPSupply.com/p-6798-Hoffman-A1001YZUMC2-Purging-Pressurization-System-10-CF.aspx

Summary of Contents for 1001A Series

Page 1: ...cessories Supplied with Each Kit Pentair Technical Products 2100 Hoffman Way Anoka Minnesota 55303 PH 763 422 2211 hoffmanonline com Hoffman P N 87571946 Manufactured by 1600 Enterprise Parkway Twinsb...

Page 2: ...subject to change without notice Table of Contents Page 2 System Purpose and Description Purpose System Description Important Notes Page 3 Identifying Your System Defines specific features of the syst...

Page 3: ...ion proof differential pressure switch used to detect loss of safe enclosure pressure LPS Less Pressure Switch SYSTEM TYPE Type Z Reduces the internal enclosure area Division rating from Division 2 to...

Page 4: ...re Warning Nameplate Silkscreened SS Recommended Spare Parts Qty Description Part supercedes 1 Enclosure Pressure Indicator CI 510023 1 Enclosure Pressure Indicator CII 513235 1 Enclosure Pressure Con...

Page 5: ...Calculation 1 The total volume of all pressurized enclosures devices and wireways must be considered 2 All enclosure device and wireway volumes must be calculated without consideration of internally...

Page 6: ...SERVICE VALVE SYSTEM SUPPLY FITTING ENCLOSURE PROTECTION SYSTEM SYSTEM MOUNTING BOLT ENCLOSURE SUPPLY TUBING ENCLOSURE PROTECTION VENT optional PROTECTED ENCLOSURE ENCLOSURE CONNECTION FITTINGS ENCLOS...

Page 7: ...OUTLET OUTLET B TYPICAL MULTIPLE PROTECTED ENCLOSURE CONNECTIONS 1 2 PROTECTIVE GAS SUPPLY HEADER A A D C Connections for Lighter than Air Gases and Vapors HELPFUL HINTS If flammable gases are lighte...

Page 8: ...ions are intended for mounting adjacent to the protected enclosure LH RH TM BM configurations are also suitable for 2 schedule 40 pipe mounting In addition these configurations can be accessorized wit...

Page 9: ...LLED IN LINE FILTER KIT ACCESSORY Provides an 8 5 oz capacity 40 micron protective gas supply filter factory installed on the inlet side of the enclosure pressure control regulator Typical Surface Mou...

Page 10: ...10 10 Mounting Plate Dimensions Model 1001A Face Plate 9 8 9 8 RSPSupply 1 888 532 2706 www RSPSupply com http www RSPSupply com p 6798 Hoffman A1001YZUMC2 Purging Pressurization System 10 CF aspx...

Page 11: ...25 TYP 4 Flange Depth 6 3 375 1 1 0 675 0 5 Universal Flange Footprint Optional Wall Flange Footprint only available from Pepperl Fuchs RSPSupply 1 888 532 2706 www RSPSupply com http www RSPSupply c...

Page 12: ...cted enclosure The length of time required is determined by the customer and can be factory or field engraved All EWNs and ETWs are furnished with an adhesive back but should also be riveted or screwe...

Page 13: ...odel ILFK accessory See photo on page 9 One 1 Similar fitting which will connect the inert gas supply tubing to the inert gas supply header connection point and one 1 lot of 1 4 O D 035 wall thickness...

Page 14: ...closure protection system whenever possible For systems protecting multiple enclosures in series the enclosure reference connection fitting must be placed on the last enclosure in the series see page...

Page 15: ...nections are bolded System Supply Venturi Orifice Inlet Enclosure Pressure Gauge Regulator Sintered Vent Reference Supply Enclosure Reference Bulkhead fitting Enclosure Supply Bulkhead fitting System...

Page 16: ...or 500 3 as required and all relevant plant and local codes Note Do not use seals on conduit used as a protected wireway to supply protective gas to adjacent protected enclosures The same conduit can...

Page 17: ...ocked position upon arrival To adjust regulator pull handle to outward position 1 Close the Enclosure Pressure Control Regulator fully by turning counterclockwise CCW 2 Temporarily connect the inert g...

Page 18: ...ed if utilized 1 Carefully read Start Up Instruction Nameplate on system 2 CheckoperationoftheEnclosureProtectionVent EPV 1 if utilized opening it manually several times see page 17 Helpful Hint 3 Sea...

Page 19: ...osure Remove the orifice cut off the crimped end and ream the tube then recrimp and reinstall the tube to note effect As tube is shortened reamed andrecrimped sensitivitydecreases allowingeasieradjust...

Page 20: ...O THE PRODUCTS IT IS EXPRESSLY AGREED AND UNDERSTOOD THAT P F MAKES NO WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE EXCEPT FOR THE LIMITED WARRANTY SET FORTH HEREIN THERE IS NO OTHE...

Page 21: ...ing to the set up procedure and operating sequence on pages 17 and 18 Replace or tighten stem packing nut as required to prohibit stem packing leakage Carefully disassemble the enclosure protection ve...

Page 22: ...22 22 CUSTOMER NOTES RSPSupply 1 888 532 2706 www RSPSupply com http www RSPSupply com p 6798 Hoffman A1001YZUMC2 Purging Pressurization System 10 CF aspx...

Page 23: ...23 23 CUSTOMER NOTES RSPSupply 1 888 532 2706 www RSPSupply com http www RSPSupply com p 6798 Hoffman A1001YZUMC2 Purging Pressurization System 10 CF aspx...

Page 24: ...omer Project Service Type Features Application SYSTEMS IDENTIFICATION APPLICATION INFORMATION Local Sales Representative NOTES RSPSupply 1 888 532 2706 www RSPSupply com http www RSPSupply com p 6798...

Reviews: