13

13

pneumatic tubing Requirements

protective Gas supply Requirements

The protective gas supply to the protection system must 
be a clean, instrument quality compressed air or nitrogen 
and must contain no more than trace amounts of flammable 
gas, vapor or dust.

The protective gas supply compressor intake must originate 
in a nonhazardous location.  Suction duct passing through 
a  hazardous  location  and  the  protection  system  tubing 
and  piping  must  be  fabricated  from  noncombustible 
materials suitable for prevailing hazards and environmental 
conditions. 

The protective gas supply must originate from a dedicated 
instrument quality compressed air header (1/2" pipe or larger), 
no farther than twenty (20) feet from the protection system.  
Local compressors and gas cylinders should not be used 
before consulting with Fuchs.

The protective gas supply to the protection system must 
be  equipped  with  a  tamper-proof  regulator  set  at  5  psi 
maximum.

Exception:

  If the protected enclosure(s) is equipped with 

a Fuchs Enclosure Protection Vent, the protective 
gas  supply  to  the  protection  system  must  not  exceed 
120 psi maximum, 5 psi minimum. (See page 4, "System 

pneumatic Connection Requirements

ALL FITTINGS MAy BE CUSTOMER OR FACTORy FURNISHED

1.  For system supply, one (1) SC-4 1/4" Male Straight Con-

nector or one (1) NC-4 1/4" Male Elbow Connector or 
equivalent fitting per system.

 

notE:    above  fitting  is  required  only  if  protection 
system is furnished with an optional In line Filter Kit 
(Model IlFK) accessory.  see photo on page 9

 

One (1) Similar fitting which will connect the inert gas 
supply tubing to the inert gas supply header connection 
point and one (1) lot of 1/4" O.D., .035" wall thickness, 
welded or seamless stainless steel tubing.

2.  For enclosure supply, one (1) EFC-4 1/4" Flush Connector, 

or  one  (1)  EBC-4  1/4"  Feed-Through  Connector  or 
equivalent fitting per system.

3.   For  enclosure  reference,  one  (1)  EFC-4  1/4"  Flush 

Connector,  or  one  (1)  EBC-4  1/4"  Feed-Through 
Connector or equivalent fitting per system.

4.    One (1) lot of 1/4" O.D., .035" wall thickness, welded or 

seamless stainless steel tubing.

 

notE:  above fittings and tubing are not required if 
system is furnished with an Enclosure Connection 
Kit (Model ECK) accessory.  see photo on page 9

5.    For multiple enclosure connections, two (2) EPC-10 1/2" 

Pipe Mounting Hubs or equivalent and 1/2" 150# rated 
pipe couplings & unions per interconnection.

 

One (1) lot 150# rating 1/2" galvanized or aluminum pipe 
and fittings, fully reamed and unrestricted.

 

In addition to item numbers 1, 4 and 5 above, the following 
fittings are required for all PM configurations. 

1.  For system supply on PM configurations, one (1) additional 

EBC-4 or equivalent 1/4" Through Bulkhead Fitting per 
system is required.

2.  For atmospheric reference, one (1) PRB-4 or equivalent 

1/4" female bulkhead fitting and stainless steel sintered 
element is required.

pM pneumatic Connection Requirements

sC-4

nC-4

EBC-4

EFC-4

EpC-10

pRB-4

sYstEM sUpplY FIttInGs

EnClosURE sUpplY & REFEREnCE FIttInGs

MUltIplE EnClosURE ConnECtIon FIttInG

sYstEM atMospHERIC REFEREnCE FIttInG

RSPSupply  -  1-888-532-2706 -  www.RSPSupply.com

http://www.RSPSupply.com/p-6798-Hoffman-A1001YZUMC2-Purging-Pressurization-System-10-CF.aspx

Summary of Contents for 1001A Series

Page 1: ...cessories Supplied with Each Kit Pentair Technical Products 2100 Hoffman Way Anoka Minnesota 55303 PH 763 422 2211 hoffmanonline com Hoffman P N 87571946 Manufactured by 1600 Enterprise Parkway Twinsb...

Page 2: ...subject to change without notice Table of Contents Page 2 System Purpose and Description Purpose System Description Important Notes Page 3 Identifying Your System Defines specific features of the syst...

Page 3: ...ion proof differential pressure switch used to detect loss of safe enclosure pressure LPS Less Pressure Switch SYSTEM TYPE Type Z Reduces the internal enclosure area Division rating from Division 2 to...

Page 4: ...re Warning Nameplate Silkscreened SS Recommended Spare Parts Qty Description Part supercedes 1 Enclosure Pressure Indicator CI 510023 1 Enclosure Pressure Indicator CII 513235 1 Enclosure Pressure Con...

Page 5: ...Calculation 1 The total volume of all pressurized enclosures devices and wireways must be considered 2 All enclosure device and wireway volumes must be calculated without consideration of internally...

Page 6: ...SERVICE VALVE SYSTEM SUPPLY FITTING ENCLOSURE PROTECTION SYSTEM SYSTEM MOUNTING BOLT ENCLOSURE SUPPLY TUBING ENCLOSURE PROTECTION VENT optional PROTECTED ENCLOSURE ENCLOSURE CONNECTION FITTINGS ENCLOS...

Page 7: ...OUTLET OUTLET B TYPICAL MULTIPLE PROTECTED ENCLOSURE CONNECTIONS 1 2 PROTECTIVE GAS SUPPLY HEADER A A D C Connections for Lighter than Air Gases and Vapors HELPFUL HINTS If flammable gases are lighte...

Page 8: ...ions are intended for mounting adjacent to the protected enclosure LH RH TM BM configurations are also suitable for 2 schedule 40 pipe mounting In addition these configurations can be accessorized wit...

Page 9: ...LLED IN LINE FILTER KIT ACCESSORY Provides an 8 5 oz capacity 40 micron protective gas supply filter factory installed on the inlet side of the enclosure pressure control regulator Typical Surface Mou...

Page 10: ...10 10 Mounting Plate Dimensions Model 1001A Face Plate 9 8 9 8 RSPSupply 1 888 532 2706 www RSPSupply com http www RSPSupply com p 6798 Hoffman A1001YZUMC2 Purging Pressurization System 10 CF aspx...

Page 11: ...25 TYP 4 Flange Depth 6 3 375 1 1 0 675 0 5 Universal Flange Footprint Optional Wall Flange Footprint only available from Pepperl Fuchs RSPSupply 1 888 532 2706 www RSPSupply com http www RSPSupply c...

Page 12: ...cted enclosure The length of time required is determined by the customer and can be factory or field engraved All EWNs and ETWs are furnished with an adhesive back but should also be riveted or screwe...

Page 13: ...odel ILFK accessory See photo on page 9 One 1 Similar fitting which will connect the inert gas supply tubing to the inert gas supply header connection point and one 1 lot of 1 4 O D 035 wall thickness...

Page 14: ...closure protection system whenever possible For systems protecting multiple enclosures in series the enclosure reference connection fitting must be placed on the last enclosure in the series see page...

Page 15: ...nections are bolded System Supply Venturi Orifice Inlet Enclosure Pressure Gauge Regulator Sintered Vent Reference Supply Enclosure Reference Bulkhead fitting Enclosure Supply Bulkhead fitting System...

Page 16: ...or 500 3 as required and all relevant plant and local codes Note Do not use seals on conduit used as a protected wireway to supply protective gas to adjacent protected enclosures The same conduit can...

Page 17: ...ocked position upon arrival To adjust regulator pull handle to outward position 1 Close the Enclosure Pressure Control Regulator fully by turning counterclockwise CCW 2 Temporarily connect the inert g...

Page 18: ...ed if utilized 1 Carefully read Start Up Instruction Nameplate on system 2 CheckoperationoftheEnclosureProtectionVent EPV 1 if utilized opening it manually several times see page 17 Helpful Hint 3 Sea...

Page 19: ...osure Remove the orifice cut off the crimped end and ream the tube then recrimp and reinstall the tube to note effect As tube is shortened reamed andrecrimped sensitivitydecreases allowingeasieradjust...

Page 20: ...O THE PRODUCTS IT IS EXPRESSLY AGREED AND UNDERSTOOD THAT P F MAKES NO WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE EXCEPT FOR THE LIMITED WARRANTY SET FORTH HEREIN THERE IS NO OTHE...

Page 21: ...ing to the set up procedure and operating sequence on pages 17 and 18 Replace or tighten stem packing nut as required to prohibit stem packing leakage Carefully disassemble the enclosure protection ve...

Page 22: ...22 22 CUSTOMER NOTES RSPSupply 1 888 532 2706 www RSPSupply com http www RSPSupply com p 6798 Hoffman A1001YZUMC2 Purging Pressurization System 10 CF aspx...

Page 23: ...23 23 CUSTOMER NOTES RSPSupply 1 888 532 2706 www RSPSupply com http www RSPSupply com p 6798 Hoffman A1001YZUMC2 Purging Pressurization System 10 CF aspx...

Page 24: ...omer Project Service Type Features Application SYSTEMS IDENTIFICATION APPLICATION INFORMATION Local Sales Representative NOTES RSPSupply 1 888 532 2706 www RSPSupply com http www RSPSupply com p 6798...

Reviews: