Error codes on RRC display
Error code
Description
Method to reset
Unplug from
mains
supply
Remote
control
Automatic
reset
E1001 Pentpak ambient temperature too high
x
E1002 Pentpak cooling system, temperature too high
x
E1201, E1301 Emergency stop or Green button on Pentpak faulty
x
E1003 Main motor shut off due to slip clutch slipping
MS
E1004, E1604, E1605 Main motor temperature sensor fault
x
E1008, E1608, E1609 Arm feed motor temperature sensor fault
x
E1006, E1606, E1607 Travel motor temperature sensor fault
x
E1200, E1202-E1217
E1300, E1302-E1317 Internal fault, Pentpak control card
x
E1400 Internal fault, Pentpak control card, radio module
x
E1600 Saw arm position sensor fault
x
E1602 Slip clutch sensor fault
x
E1607 Main motor overheated
x
E1009 Arm feed motor overheated
x
E1007 Travel motor overheated
x
E1699 No communication with saw unit, RS2
x
E1800 Remote control switch/button/joystick sensor fault
x
E1801 Remote control battery charging fault
x
E2100, E2101 Hardware error, Pentpak, drive board, arm feed
x
E2200, E2201 Hardware error, Pentpak, drive board, travel
x
E2400, E2401 Hardware error, Pentpak, drive board, main motor
x
E2102, E2202, E2402 Machine cable failure, open circuit
x
E2103, E2203, E2403 Machine cable failure, leakage or faulty connection
x
E2109 Overcurrent detected, arm feed
Joystick
E2209 Overcurrent detected, travel
Joystick
E2409 Overcurrent detected, main motor
MS
E2111, E2211, E2411 Internal fault, Pentpak, drive board
x
E2113, E2213, E2413 Over voltage, mains supply to Pentpak
MS
E2114, E2214, E2414 Under voltage, mains supply to Pentpak
MS
E2115, E2215, E2415 Internal fault, Pentpak drive board
x
E2808-E2813 Pentpak rectifier fault
x
E2850 Under voltage, mains supply to Pentpak
MS
E2851 Over voltage, mains supply to Pentpak
MS
E2853 Line phase missing, mains supply to Pentpak
x
There are more Error codes which can occur. Contact your Pentruder authorized service workshop for information.