Operator’s manual Pentruder RS2 wall saw and Pentpak 3 HFi power pack – Original instructions
Page 15
Mounting of track feet and tracks
3.3.1
Positioning of track feet
1.
Use the Pentruder templates to simplify the setup of the wall saw. It will help position the track feet to avoid
re-aligning them when cutting a rectangular opening. The track foot can swivel, so it only needs to be set up
once at each corner, for example when cutting a door opening.
2.
Minimum two track feet are required to mount one track. The distance between the track feet may not
exceed 2.0 meters (79”). If blades larger than 1200 mm / 48” are used, set the track feet closer than 2.0
meters / (79”).
3.
If tracks with only one gear rack are used, make sure all of them are positioned correctly to engage with the
travel gear on the wall saw.
The distance from the edge of the feet to the cut line is
127 mm (5”). The distance from anchor bolt to the cut
line is 217 +- 25 mm (8.54 +- 1”).
Setup examples
!
Important!
The feet must be fixed with M12 (1/2”) screws of 8.8 quality or higher of adequate
length, depending on anchor depth, using a thick washer and anchors of type HKD
M12 (1/2”) or equivalent.