76700 -36/94-
*Install LCD block
(6) TY-CNL-D1.7x3.5 (x2)
(7) CNL-D1.7x2.5
(8) [Confirm] You must feel click when turning electronic dial.
10. [CONF] CCD Base Plate Support Pillar
[Required equipment] Block gauge for 35mm, Dial gauge comparator, etc. (same as MZ series)
(1)
Measure height of the CCD base support pillar (3 places) from the mount surface as shown in the figure.
(There are four kind of height)
Distinction
Last two digit of
lot number
[-00]
From [-01]
to [-03]
[-04] and later
[-13] and later
Tolerance:
(Only fot 76700)
49.876±0.02 mm
49.676±0.02
49.640±0.02
49.610±0.02
Using Block
gauge for 35mm
(45.46mm)
+4.416 ±0.02 mm
(+4.396~4.436 mm)
+4.216 ±0.02
(+4.196~4.236)
+4.18 ±0.02
(+4.16~4.20)
+4.15 ±0.02
(+4.13~4.17)
Height of Pillar
Previous parts (±0)
New parts
(-0.2)
New Parts
(-0.236)
New parts
(-0.266)
Shape of plate for
0-C000
Previous oarts :
counterbore (-0.2)
New parts:
No counterbore
(±0)
New parts:
No counterbore
(±0)
Borad thickness
Tolerance :
t=1.6 (+0.01
~-0.03)
New parts:
No counterbore
(±0)
Modified Borad
thickness
Tolerance :
t=1.6 (+0.03
~-0.01)
(6)
(7)
LCD block
+4.
+0.416
or
+0.216
or
+0.18
or
+0.15
+4.416
,
+4.216
,
+4.18
or
+4.15
Summary of Contents for K 100D Super
Page 1: ...PENTAX Service Co Ltd Technical Service Dep Product No 76700 TM 仮サービスマニュアル TM TM ...
Page 5: ...76700 4 94 Click OK Do not click Directory Click installation button ...
Page 6: ...76700 5 94 Set up will be started Click OK to end the installation ...
Page 49: ...76700 48 94 6 A74 TYscrew x2 5 5mm 7 Close SD card cover 6 7 ...