![Pentax ist D Service Manual Download Page 42](http://html.mh-extra.com/html/pentax/ist-d/ist-d_service-manual_1526781042.webp)
76180 EM -41/73-
22-2 [CONF] Static Current
①
Connect the DC cord to the camera and then the camera will be turned ON. At this time,
there must be neither short nor Leakage.
22-3 [CONF] Preview
・
LCD panel illumination
①
When the main SW is turned to , the diaphragm actuate lever must be done vertical
motion.
②
When the main SW returns to ON, the LCD display must be illuminated.
22-4 [CONF] Switch Function
①
Turn the main SW to OFF and insert the CF card (for Testing)
into the camera.
②
Turn the main SW to ON while opening the CF card cover,
and the screen for SW testing will be displayed on the LCD
monitor.
③
Operate each SW and the dial according to the LCD monitor. The color of the display
changes according to the operation when normally working. (See the table below)
④
Turn the main SW to OFF and remove the CF card from the camera.
Symbol
Button
Color display
Symbol
Button
Color display
a. SWS
release button
Change
v. MODE
Mode dial
Display code
b. SWR
Release button
Change
Green
Green mode
00
c. PRV
Preview dial
Change
P
Program
08
d. FLPOP
Pop-up
Change
TV
TV mode
0C
e. AFSTART
AF button
Change
AV
AV mode
04
f. MENU
MENU
Change
M
Manual mode
06
g. ERASE
Trash
Change
B
Bulb mode
0E
h. INFO
INFO button
Change
ISO
ISO mode
02
i. DISPLAY
Arrow
Change
File mode
03
j. 4WR
4 way button
Change
WB
White Balance
01
k. 4WL
4 way button
Change
w. AEMODE
Metering mode lever Display
code
l. 4WD
4 way button
Change
SPOT
SPOT
02
m. 4WU
4 way button
Change
CENTER-WEIGHTED
CENTER-WEIGHTED
00
n. XVAVSET
Exp. compensation button
Change
MULTI-SEGMENT
MULTI-SEGMENT
01
o. AEL
AEL button
Change
x. AFAREA
Focus point select lever Display
code
p. AEB
DPOF button
Change
SPOT
SPOT
02
q. FLMD
Flash button
Change
SEL
SEL
00
r. DRIVE
Self timer btn
Change
AUTO
AUTO
01
s. IF
Green dot
Change
y. AFMODE
Focus mode SW Display
code
Static current:
Main SW/OFF
・・・
Ave.10mA
Main SW/ON (Light metering OFF)
・・・
Ave.240mA
Main SW/ON (Light metering ON)
・・・
Ave.420mA
on the Auto power OFF condition
・・・
Ave.10mA