![Pentax ist D Service Manual Download Page 19](http://html.mh-extra.com/html/pentax/ist-d/ist-d_service-manual_1526781019.webp)
76180 EM -18/73-
1
2
3
4
5
①
②
③
④
⑤
⑥
⑦
⑨
⑩
⑧
6. A104
①
0-A126
②
TY-CNL-D1.7x3.0
③
A133
④
0-A121
⑤
TY-CNL-F1.4x4.0
⑥
A105
⑦
0-A108
⑧
A110
⑨
A104
⑩
TY-CNS2.0x4.5Ni (5pcs.)
・・・
Tighten 5 screws in the numerical order
as shown in the figure above.
⑪
Solder a black lead wire.
・・・
T71
7. [ADJ] Positioning 1
st
and 2
nd
Mirror
[Required equipment] 1
st
Mirror angle (45°) adjusting jig, Mirror angle adjusting jig for 27830,
Mirror positioning scope
[NOTE] The manner of adjusting is the same as the other MZ-cameras. Adjust the desired
value of Y axis to
±
0.
①
Positioning 1
st
mirror: Put the 1
st
mirror angle (45°) adjusting jig on the camera, and then
adjust the mirror seat so that the adjusting jig touches the mirror without gap by turning
B58.
②
Positioning 2
nd
mirror: Attach the mirror positioning scope and the 2
nd
mirror angle
adjusting jig to the camera, and then adjust the mirror angle by turning B58 while looking
through the eyepiece lens.
Tolerance
・・・
X-axis
:
±
15
′
Y-axis :
±
10
′
1st mirror
B58
2nd mirror
⑪