77420 - 80/107 -
8-4.Procedure for adjustment (Kr_PDCAdj)
①
Connect the camera and PC with USB cable and turn ON the camera.
②
Double click [Kr_PDCAdjv204.exe] in
[Kr_ PDCAdj] folder to start up software.
↓
③
Click [SHUTTER SPEED]. Then it can push the [INPUT] button.
④
Input shutter speed data (EX: 0.26ms) and click [Input Data] button.
⑤
If data is NG, input [0.26]and click [Input Data].
(
⑤
become effective)
⑥
When completed the adjustment, click in order to [Close]
→
[Cl]
”
Unconnect
”
→
[end] to finish the
program software.
⑦
[Confirm]
confirm the deviation by histogram again and confirm the shutter speed should be within
below tolerance.
Tolerance for adjustment:
0.224~0.290mS(Standard:0.265mS, Tv4000)
⑧
[Confirm]
confirm Tv6000by histogram. There is no big difference from Tv4000.
LV8
LV9
Shutter speed
(
mS
)
1/4000
1/6000
1/4000
1/6000
ISO sensitivity
ISO3200
ISO6400
ISO1600
ISO3200
Main screen
Input data