background image

13

ThermalFlo Addendum

Replacement Parts List 

(Continued)

Item No.

Part Number

Description

1

473665

Probe Thermister Defrost Sensor

2

470284

Nut, J-Clip

3

473285

Nut, 1/4 - 20 SS Acorn

4

470281

Nut, U-Clip

5

470147

Wire Harness, Compressor

6

473024

Compressor, Trane GH633-LL1-G (Model # 500, 700, 900)

6

473025

Compressor, Trane GH673-LL1-G (Model # 1200, 1200R)

7

473295

Fender Washer

8

473026

Compressor Isolation kit, Grommet and Spacer (1 Set)

9

473294

Bolt 5/16 - 18 x 1.75" SS

10

98219800

Bolt 5/16 - 18 x 1" SS

11

473121

Drier (Model # 500, 700, 900, 1200)

11

473139

Drier, Reversible (Model # 1200R)

12

470441

Fan Guard Fastener Kit

13

71406

Nut, 1/4 - 20 Hex SS

14

473693

Bezel, Control Board w/ Label

15

473602

Auto Heat Control Board

16

473603

Pump Contactor AutoHeat

17

473150

Fan Relay

18

473155

Transformer

19

473422

Wire Harness Terminal Block - Fan, Compressor

20

473315

Wire Harness, Terminal Block - Sensors

21

470146

Capacitor

22

473149

Contactor, Heat Pump

23

473423

Wire Harness, Main

24

473412

Panel, Front Right(Model# 500, 700)

24

473431

Panel, Front Right(Model# 900, 1200, 1200R)

25

470159

Screw #10 x .75" Pan Head Phillips, Almond Head

26

470161

Screw #10 x 1" Button Head Torx, Almond Head

27

470419

Panel, Front Left, w/ Decal (Model# 500, 700)

27

470434

Panel, Front Left, w/ Decal (Model# 900, 1200, 1200R)

28

473134

HP Top

29

473368

Guard, Fan

30

470439

Nut, 10-32 SS Acorn

31

470289

Fan Motor w/ Acorn nut Kit

32

473223

Fan Blade

33

470137

Tie Down Bracket

34

471566

Probe Thermister - Water Temperature

35

473606

Water Pressure Switch Boot

36

473605

Water Pressure Switch

37

472737

Titanium Heat Exchanger (Model# 500)

37

472736

Titanium Heat Exchanger (Model# 700, 900, 1200, 1200R)

38

473664

Water Bypass Manifold w/ 2 Street Elbows

39

R172305

Water Bypass Check Valve

40

473381

Union PVC 2"

41

473656

Switch, Low Pressure

42

473655

Switch, High Pressure

43

472735

Thermostatic Expansion Valve

44

473657

Titanium Water Coil Tie Down Strap

473135

Reversing Valve (Model # 1200R) [Not shown]

473136

Reversing Solenoid (Model # 1200R) [Not shown]

Summary of Contents for ThermalFlo Heat Pump Contol Panel Addendum

Page 1: ...ThermalFlo Heat Pump Autoset Control Board Addendum IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS ...

Page 2: ...p Wiring Diagram 10 AutoSet Contactor to Mechanical Timer Wiring Example 11 Replacement Parts List 12 ThermalFlo Heat Pump Contol Panel Addendum The information in this addendum supercedes information in the ThermalFlo Installation and User s Guide P N 473426 Rev C 10 19 06 For additional information not covered in this addendum please refer to the above named manual Technical support Phone 800 83...

Page 3: ...cool or auto mode will be displayed along with the active set point pool or spa On subsequent presses the use of the pool or spa setpoints will be toggled You can also toggle between the pool and spa set point by using the Up and Down arrow buttons 4 Up and DownArrow buttons Use the Up and Down arrows to raise or lower the temperature setpoint while in the Run screen These buttons are also used to...

Page 4: ...splayed With that screen displayed adjust the setpoint with the UP and DOWN arrows The screen will automatically return to the active run screen after 15 seconds of keypad inactivity c The maximum water temperature set point in Pool mode is 95 F d The maximum water temperature set point in Spa mode is 104 F 3 Toggling between Pool and Spa The active mode of operation between Pool and Spa can be ch...

Page 5: ...and common connections the heat pump will start as long as the water temperature is not over the local set point under for chiller operation The local set points are activeinrelayremoteoperation a If the heat pump is to be controlled by a remote device such as an automation system the heat pump set point should be made higher if heating than the desired temperature For example if your remote conne...

Page 6: ...r cooling if the Pool setpoint is active This screen also displays the water temperature setpoint and the actual measured water temperature The Pool setpoint can be raised or lowered using the up and down arrows while this screen is displayed The display will automatically return to this screen after 15 seconds of push buttoninactivitywhenthePoolsetpointisactive 2 Spa Run Screen Displays whether t...

Page 7: ...tart pump start sensing water temperature or defrost delays this screen shows how much delay time is left 7 Defrost Temperature This screen is only shown if the defrost feature is enabled during operator setup If the Defrost feature is enabled this screen will display the temperature of the compressor suction line This temperature is used to determine when the heat pump requires defrosting 8 Alarm...

Page 8: ...pump will accept IntelliTouch RS 485 command Adjusted to On or Off with the UPand DOWN arrow buttons 5 Temperature Scale The control board can display temperatures in either degrees Fahrenheit or Celsius The temperature scale in use can be changed as described below a Press the MENU SELECTbutton repeatedly until theTemperature Scale screen is displayed Once displayed press the UP or DOWN arrows to...

Page 9: ...s simultaneously DEFROST CYCLE At air temperatures below 50 F the heat pump may enter a defrost cycle The defrost cycle is initiated when a sensor on the evaporator detects that the refrigerant temperature has fallen below the defrost set point At this time the heat pump compressor will stop The heat pump evaporator fan will continue to run and will draw air over the evaporator fins for about 15 m...

Page 10: ... Once the 4 hours has expired at 1 00 am the control board will energize the internal contactor in the heat pump to turn on your water circulation pump 4 Theheatpumpwillsensewatertemperaturethendetermineifitneedstocontinuetocirculate water If the pool temperature has fallen below your set point 80 degrees for this example the heat pump will turn on and begin heating the pool Once the pool temperat...

Page 11: ...t i u c r i c r o t s i m r e h t e r u t a r e p m e t r e t a W T R O H S H T N O I T C U S d e t r o h s t i u c r i c r o t s i m r e h t t s o r f e D N E P O H T N O I T C U S n e p o t i u c r i c r o t s i m r e h t t s o r f e D T U O N W O R B w o l s i d r a o b l o r t n o c e h t o t e g a t l o v y l p p u s C A V 4 2 e h T G I R F E R H G I H n e p o s i h c t i w s e r u s s e r p ...

Page 12: ...P THERM1THERM2 COM SPA POOL INPUT SWITCHES J9 WTR TEMP J4 DEF TEMP J5 3 WIRE REMOTE TERM PWR J7 RS 485 J8 INTELLITOUCH CONNECTION BLACK OUTPUTS J3 BLACK WHITE PURPLE BLACK BLACK Capacitor 50 mf 7 5 mf FAN HERM C Transformer 208V 240V 24 VAC COM Filter Pump Contactor Compressor Contactor Fan Relay NO NC BLACK RED BLACK BLUE BLUE WHITE RED WHITE RED WHITE RED WHITE PURPLE ORANGE BLACK YELLOW Tan WHI...

Page 13: ...4 Timer CLOCK MOTOR 240V SUPPLY GROUND LINE 1 LINE 2 FILTER PUMP GROUND AutoSet Contactor A 1 2 3 4 NOTES 1 Mechanical timer is not provided with the heat pump 2 Example only other timers will be similarly wired 3 Ensure that the elecrical power lines are not crossed when making connections ...

Page 14: ...12 ThermalFlo Addendum 21 18 16 SCALE 1 4 19 22 17 20 23 38 12 14 30 37 42 6 35 40 9 24 15 26 8 31 2 25 7 44 13 36 32 25 29 43 11 10 34 28 27 39 5 33 25 41 4 3 1 Replacement Parts List ...

Page 15: ...6 Capacitor 22 473149 Contactor Heat Pump 23 473423 Wire Harness Main 24 473412 Panel Front Right Model 500 700 24 473431 Panel Front Right Model 900 1200 1200R 25 470159 Screw 10 x 75 Pan Head Phillips Almond Head 26 470161 Screw 10 x 1 Button Head Torx Almond Head 27 470419 Panel Front Left w Decal Model 500 700 27 470434 Panel Front Left w Decal Model 900 1200 1200R 28 473134 HP Top 29 473368 G...

Page 16: ...entairpool com www staritepool com 2007 Pentair Water Pool and Spa Inc All rights reserved 1620 HawkinsAve Sanford NC 27330 919 566 8000 10951 West LosAngeles Ave Moorpark CA93021 805 553 5000 P N 472747 Rev B 5 17 07 ...