Pentair PRF-RO Installation And Maintenance Manual Download Page 8

Recommended Placement Positions

The RO assembly should be positioned in one of two ways. 
The first position is with the unit standing upright using the support 

leg with the sumps horizontal. The tubing is directed to provide the 

best fit.
The second position, sets the unit on end so the sumps are pointing 

up. The tubing is directed upward and the locking bar is down to lock 

the tubing connections. See Figure 9  System Positions. 

NOTE: Ensure that the support leg is installed on the sumps.

Connection Lubrication

Connections with O-rings must be properly lubricated. The following 

instructions describe the method and locations for lubrication.
Six packets of silicone lube are supplied. One packet should be 

completely used to lubricate the O-ring contact surfaces in the 3 

manifold ports and 2 RO membrane locations (Figure 10). Follow 

Figure 11 and lubricate the filter seat and the flat surface below the 

threads for the 3 sump locations. Use a complete packet of silicone 

for each sump location.

NOTE: To properly lubricate the O-ring contact area, a film of clean 

silicone grease is applied. The film should cover all of the 

surface area that the O-ring will slide over and seal with. Do 

not use grease containing petroleum products.

INSTALLATION cont.

Figure 9   System Positions

First Position

Locking Bar

Second Position

Support Leg

Figure 11   

Figure 10   

8

Summary of Contents for PRF-RO

Page 1: ...properly rinse out the preservative The preservative is not harmful but makes the product water taste objectionable Rinsing the membrane also acts a performance conditioner All new membranes will reac...

Page 2: ...W TUBING INSTALL KIT PN 1255736 3 8 BLACK TUBING 4 ft 3 8 BLUE TUBING 4 ft 1 2 NATURAL TUBING 4 ft 1 2 RED TUBING 3 ft SILICONE LUBRICANT FEED DISCONNECT ELBOW WHITE PN 3035307 1 pc PERMEATE DISCONNEC...

Page 3: ...Coupling Install above P trap Locking Bar Keep to Minimum Prefilter RO Membrane Support Leg sump wrench Manifold Elbow Connectors Feed Pressure Gauge Drain Point A suitable drain point is needed for r...

Page 4: ...Air Gap Required Inlet 1 2 Natural Drain 3 8 Black Feed Water Valve Cold Water Line Only Carbon Postfilter Product 3 8 Blue RO Assembly Keep to Minimum THE BASIC REVERSE OSMOSIS SYSTEM cont Figure 3...

Page 5: ...Line Only Feed Pressure Gauge RO Assembly External Prefilter Product Storage Tank To Point of Use Vented to Atmosphere Liquid level float sensor to control feed solenoid valve Feed Solenoid Valve Figu...

Page 6: ...d that there is space underneath for tubing 2 If drilling is needed make a 1 1 2 inch diameter hole WARNING To avoid damaging a sink consult a qualified plumber or installer for the proper method of d...

Page 7: ...cure the connection NOTE When sliding tubing into the drain adapter inlet wet the tubing Water will help the tubing slide into the rubber inlet Feed Pressure Gauge The supplied pressure gauge can be c...

Page 8: ...ng instructions describe the method and locations for lubrication Six packets of silicone lube are supplied One packet should be completely used to lubricate the O ring contact surfaces in the 3 manif...

Page 9: ...eats in the manifold that come in contact with the sump and element O rings Refer to Connection Lubrication on page 8 NOTE To properly lubricate the O ring contact area a film of clean silicone grease...

Page 10: ...ening the faucet CAUTION Even with the water supply turned off the membrane and prefilter sumps will contain a considerable amount of water By positioning the RO assembly in a sink or tub most of the...

Page 11: ...ubing back approximately 1 4 inch prior to connecting the new postfilter Make sure flow direction arrow aligns with water path Reinsert tubing and collect locks 11 Re connect the fittings to the manif...

Page 12: ...78 C Inlet TDS 50 mg L 2 000 mg L Inlet Hardness 0 mg L 0 grain 171 mg L 10 grain Inlet Chlorine 0 mg L 1 0 mg L Inlet Iron 0 mg L 0 1 mg L Inlet Manganese 0 mg L 0 05 mg L Inlet pH 4 10 Inlet Turbidi...

Page 13: ...f flow into the postfilter is acceptable replace postfilter Leak or kink in product line Find and repair leak or kink Concentrate water runs to drain after faucet shut off Plugged prefilter Replace pl...

Page 14: ...14...

Page 15: ...15...

Page 16: ...2010 Pentair Residential Filtration LLC 4000413 Rev B JE10...