Pentair PRF-RO Installation And Maintenance Manual Download Page 5

1.5" Air Gap Required

Inlet-1/2" Natural

Drain - 3/8" Black

Feed Water Valve

Cold Water Line Only

Feed Pressure 

Gauge

RO Assembly

External Prefilter

Product Storage Tank

To Point of Use

Vented to

Atmosphere

Liquid level float 

sensor to control

feed solenoid valve 

Feed Solenoid

Valve

Figure 4  Typical Light Commercial Installation

THE BASIC REVERSE OSMOSIS SYSTEM cont.

5

Summary of Contents for PRF-RO

Page 1: ...properly rinse out the preservative The preservative is not harmful but makes the product water taste objectionable Rinsing the membrane also acts a performance conditioner All new membranes will reac...

Page 2: ...W TUBING INSTALL KIT PN 1255736 3 8 BLACK TUBING 4 ft 3 8 BLUE TUBING 4 ft 1 2 NATURAL TUBING 4 ft 1 2 RED TUBING 3 ft SILICONE LUBRICANT FEED DISCONNECT ELBOW WHITE PN 3035307 1 pc PERMEATE DISCONNEC...

Page 3: ...Coupling Install above P trap Locking Bar Keep to Minimum Prefilter RO Membrane Support Leg sump wrench Manifold Elbow Connectors Feed Pressure Gauge Drain Point A suitable drain point is needed for r...

Page 4: ...Air Gap Required Inlet 1 2 Natural Drain 3 8 Black Feed Water Valve Cold Water Line Only Carbon Postfilter Product 3 8 Blue RO Assembly Keep to Minimum THE BASIC REVERSE OSMOSIS SYSTEM cont Figure 3...

Page 5: ...Line Only Feed Pressure Gauge RO Assembly External Prefilter Product Storage Tank To Point of Use Vented to Atmosphere Liquid level float sensor to control feed solenoid valve Feed Solenoid Valve Figu...

Page 6: ...d that there is space underneath for tubing 2 If drilling is needed make a 1 1 2 inch diameter hole WARNING To avoid damaging a sink consult a qualified plumber or installer for the proper method of d...

Page 7: ...cure the connection NOTE When sliding tubing into the drain adapter inlet wet the tubing Water will help the tubing slide into the rubber inlet Feed Pressure Gauge The supplied pressure gauge can be c...

Page 8: ...ng instructions describe the method and locations for lubrication Six packets of silicone lube are supplied One packet should be completely used to lubricate the O ring contact surfaces in the 3 manif...

Page 9: ...eats in the manifold that come in contact with the sump and element O rings Refer to Connection Lubrication on page 8 NOTE To properly lubricate the O ring contact area a film of clean silicone grease...

Page 10: ...ening the faucet CAUTION Even with the water supply turned off the membrane and prefilter sumps will contain a considerable amount of water By positioning the RO assembly in a sink or tub most of the...

Page 11: ...ubing back approximately 1 4 inch prior to connecting the new postfilter Make sure flow direction arrow aligns with water path Reinsert tubing and collect locks 11 Re connect the fittings to the manif...

Page 12: ...78 C Inlet TDS 50 mg L 2 000 mg L Inlet Hardness 0 mg L 0 grain 171 mg L 10 grain Inlet Chlorine 0 mg L 1 0 mg L Inlet Iron 0 mg L 0 1 mg L Inlet Manganese 0 mg L 0 05 mg L Inlet pH 4 10 Inlet Turbidi...

Page 13: ...f flow into the postfilter is acceptable replace postfilter Leak or kink in product line Find and repair leak or kink Concentrate water runs to drain after faucet shut off Plugged prefilter Replace pl...

Page 14: ...14...