Pentair PRF-RO Installation And Maintenance Manual Download Page 6

INSTALLATION

STEP 1:  Install cold water supply valve
STEP 2:  Install drain adapter
STEP 3:  Install faucet
STEP 4:  Make tubing connections
STEP 5:  Install RO assembly
STEP 6:  Put system into operation

NOTE: Consult a licensed plumber if you are not familiar with 

plumbing procedures.

Step 1: Install Cold Water Supply Valve

Comply with local plumbing codes.  A typical connection using a 

water supply valve is shown in Figure 5.

WATER SUPPLY VALVE

NOTE: Be sure to turn off the water supply and open a low faucet to 

drain the pipe.

Cold water pipes vary in size and style.  The installer will determine 

type of valve that will be used.  Install a valve on the cold water 

supply pipe to adapt 1/2-inch OD tubing.  If threaded fittings are used, 

be sure to use pipe joint compound or Teflon tape on outside threads.
Turn the valve off.

Step 2:  Install Drain Adapter

Follow the instructions in the Appendix for installation of the Drain 

Boa™, if used.
The drain adapter is designed to fit 1-1/2-inch (3.8 cm) sink drain pipe.
The adapter installs directly to the sink tailpiece. 

Step 3:  Install Faucet

A.  Prepare Mounting Hole

1.  Select a location for the faucet. Be sure it will fit flat against the 

sink or counter and that there is space underneath for tubing.

2.  If drilling is needed, make a  1-1/2-inch diameter hole.

WARNING:

 To avoid damaging a sink, consult a qualified 

plumber or installer for the proper method of drilling 

holes in porcelain or stainless steel.

B.  Assemble Faucet

The tubing and fasteners are assembled to the faucet before the 

faucet is placed in position.  This can be done above the sink.
1.  Slide the decorative ring over the tubing connections and up to 

the bottom of the faucet.

2.  Slide the gasket over the tubing connections and up to the bottom 

of the faucet.

3.  Slide the standoff onto the threaded tube, followed by the 

standard washer, the lock washer and nut.

4.  Screw the threaded hose connector on the end of the threaded 

tube.

5.  Connect the blue 3/8-inch product tubing by firmly pushing it into 

the connector.

6.  Push the black 3/8-inch tubing onto the small hose barb. The red 

1/2-inch tubing is pushed onto the large hose barb.

7.  Put the faucet into position.
8.  The horseshoe clip is positioned around the threaded pipe under 

the sink and above the standoff. This clip should engage the 

tubing connected to the air gap.

9.  Tighten the nut against the clip to hold the faucet in position.

Trim Ring

Gasket

Standoff

Nut

Locking Washer

Washer

Horseshoe Clip

Water In Connection

3/8" Drain Connection 

(Small Hose Barb)

1/2" Drain Connection 

(Large Hose Barb)

Air Gap Module

Figure 5   

Figure 6   

6

Summary of Contents for PRF-RO

Page 1: ...properly rinse out the preservative The preservative is not harmful but makes the product water taste objectionable Rinsing the membrane also acts a performance conditioner All new membranes will reac...

Page 2: ...W TUBING INSTALL KIT PN 1255736 3 8 BLACK TUBING 4 ft 3 8 BLUE TUBING 4 ft 1 2 NATURAL TUBING 4 ft 1 2 RED TUBING 3 ft SILICONE LUBRICANT FEED DISCONNECT ELBOW WHITE PN 3035307 1 pc PERMEATE DISCONNEC...

Page 3: ...Coupling Install above P trap Locking Bar Keep to Minimum Prefilter RO Membrane Support Leg sump wrench Manifold Elbow Connectors Feed Pressure Gauge Drain Point A suitable drain point is needed for r...

Page 4: ...Air Gap Required Inlet 1 2 Natural Drain 3 8 Black Feed Water Valve Cold Water Line Only Carbon Postfilter Product 3 8 Blue RO Assembly Keep to Minimum THE BASIC REVERSE OSMOSIS SYSTEM cont Figure 3...

Page 5: ...Line Only Feed Pressure Gauge RO Assembly External Prefilter Product Storage Tank To Point of Use Vented to Atmosphere Liquid level float sensor to control feed solenoid valve Feed Solenoid Valve Figu...

Page 6: ...d that there is space underneath for tubing 2 If drilling is needed make a 1 1 2 inch diameter hole WARNING To avoid damaging a sink consult a qualified plumber or installer for the proper method of d...

Page 7: ...cure the connection NOTE When sliding tubing into the drain adapter inlet wet the tubing Water will help the tubing slide into the rubber inlet Feed Pressure Gauge The supplied pressure gauge can be c...

Page 8: ...ng instructions describe the method and locations for lubrication Six packets of silicone lube are supplied One packet should be completely used to lubricate the O ring contact surfaces in the 3 manif...

Page 9: ...eats in the manifold that come in contact with the sump and element O rings Refer to Connection Lubrication on page 8 NOTE To properly lubricate the O ring contact area a film of clean silicone grease...

Page 10: ...ening the faucet CAUTION Even with the water supply turned off the membrane and prefilter sumps will contain a considerable amount of water By positioning the RO assembly in a sink or tub most of the...

Page 11: ...ubing back approximately 1 4 inch prior to connecting the new postfilter Make sure flow direction arrow aligns with water path Reinsert tubing and collect locks 11 Re connect the fittings to the manif...

Page 12: ...78 C Inlet TDS 50 mg L 2 000 mg L Inlet Hardness 0 mg L 0 grain 171 mg L 10 grain Inlet Chlorine 0 mg L 1 0 mg L Inlet Iron 0 mg L 0 1 mg L Inlet Manganese 0 mg L 0 05 mg L Inlet pH 4 10 Inlet Turbidi...

Page 13: ...f flow into the postfilter is acceptable replace postfilter Leak or kink in product line Find and repair leak or kink Concentrate water runs to drain after faucet shut off Plugged prefilter Replace pl...

Page 14: ...14...

Page 15: ...15...

Page 16: ...2010 Pentair Residential Filtration LLC 4000413 Rev B JE10...

Reviews: