Pentair Pentek Solar Drive Specifications
Input Specification:
- Minimum Operating Voltage :
100 Vdc (for 115 Vac)
150 Vdc (for 230 Vac)
- Maximum Solar Open Circuit Voltage:
400 Vdc
- Maximum Solar PV Current in Series:
9 Amps
- Earth-ground connected to chassis
Output Specification:
- Maximum Output Current:
7 Arms (3-phase motors)
- Maximum Power Sustained:
2000W
Protections:
- Short-circuit, ground-fault, over-temperature, overload, over-voltage, over-current,
and solar input reverse polarity protection
- Automatic dry well protection and pump locked rotor protection
Integral solid state short circuit protection does not provide branch circuit protection.
Branch circuit protection must be provided in accordance with the National Electrical
Code and any additional local codes.
ELECTRICAL MECHANICAL
Solar PV open circuit voltage:
400V
Operating temperature:
-40˚C to 50˚C
Max PV panel current in series:
9A
Dimensions:
10”x5.5”x4”
AC Source Terminals:
AWG #10-16
Max Three phase AC motor current:
7A
Solar Terminals:
AWG #10-16
Degree of protection:
TYPE 4
Motor terminal:
AWG #8-16
Enclosure material:
Aluminum
Float Sensor terminals:
AWG #14-20
WARNING:
Carefully check the motor load specifications and solar PV array maximum power
point voltage to set up the system properly using this manual!
Environmental
– Compliance with IEC 60068
IEC 60068-2-2 – Cold
IEC 60068-2-2 – Dry Heat
IEC 60068-2-14 – Change of Temperature
IEC 60068-2-30 – Damp Heat