background image

  

I   ©2019 Pentair plc.

Pentair Pentek Solar Drive at a Glance

Grid Power

Pentair Pentek 

Solar Drive PSD15

PV Solar Array

DC Disconnect

Water Tank

Level

Switch

AC Motor 

Pump

The Pentair Pentek Solar Drive PSD15 is an off-grid solar controller that can operate any 
approved Pentair Pentek submersible motor loads or operate approved alternative 3-phase 
alternating current (AC) motor loads up to 1.5HP from solar photovoltaic (PV) power.

To size the solar PV array to your specific motor, 
please consult with your local dealer or Pentair. A 
typical diagram for a Pentair Pentek Solar Drive 
operated solar water pumping system is shown in 
Figure 1. The solar PV array must be connected to 
an external DC Disconnect and then to the Pentair 
Pentek Solar Drive controller. The Pentair Pentek 
Solar Drive controller should be installed in the 
shade (potentially mounted under the PV array) 
and away from the direct sun. 

The Pentair Pentek Solar Drive can accept up to 
two digital sensor inputs. For example, in solar 
water pumping applications, an optional float 
switch can be connected to the Pentair Pentek 
Solar Drive to monitor when a water tank is full, or 
a pressure switch can be used in combination with 
a pressure tank. 

Figure 1: Solar Water Pumping System Diagram with  

Pentair Pentek Solar Drive PSD15

Summary of Contents for Pentek PSD15

Page 1: ...pentair com P1061 03 06 19 INSTALLATIONAND OPERATIONMANUAL SOLARDRIVEPSD15 PENTEK...

Page 2: ...e Installation Requirements 6 Pentair Pentek Solar Drive Hardware 7 Pentair Pentek Solar Drive Overview 8 Pentair Pentek Solar Drive Wiring Instructions 9 Pentair Pentek Solar Drive DIP Switch Setting...

Page 3: ...tage with a voltage tester NEVER connect power wiring to Drive before mounting the box NEVER handle or service Drive with wet or damp hands Always make sure hands are dry before working on Drive NEVER...

Page 4: ...ram for a Pentair Pentek Solar Drive operated solar water pumping system is shown in Figure 1 The solar PV array must be connected to an external DC Disconnect and then to the Pentair Pentek Solar Dri...

Page 5: ...oes not provide branch circuit protection Branch circuit protection must be provided in accordance with the National Electrical Code and any additional local codes ELECTRICAL MECHANICAL Solar PV open...

Page 6: ...n a shaded location away from any source of heat and in an area free of vegetation Measures must also be made to protect the unit from damage by unauthorized persons large animals overgrowth flooding...

Page 7: ...Drive controller should be mounted on a wall or other vertical surface using the back bracket see Figure 5 below On the back side of the unit there are two set screws used to hang the unit on the back...

Page 8: ...e enclosure is open there are three terminal blocks 1 Solar PV wires 2 Motor pump wires 3 Pump or tank sensor wires More information about sensor wiring and DIP switches is provided on page 8 Figure 6...

Page 9: ...ugh the right gland float switch signal wires feed through the middle gland and motor load wires feed through the left gland When all conductors are wired into the controller the cover door should be...

Page 10: ...ed on the motor pump and controller combination being used The default value of RMS current when both switches are OFF is 7A for three phase DIP switches 4 and 5 are to be used to match or exceed the...

Page 11: ...xample of how tank and well switch signals can be used with a digital input port is shown in Figure 10 For a tank application if the active wire is connected to Position 1 and the return wire usually...

Page 12: ...sition All LEDs will light up and after a few seconds the Pentair Pentek Solar Drive will try to start the pump indicated by a blinking green light and upon starting the green LED will remain ON 4 If...

Page 13: ...ugh solar production from the solar panels the yellow LED will start blinking again Shutdown To stop the Pentair Pentek Solar Drive s operation the DC Disconnect should be used Once in the OFF positio...

Page 14: ...PV Panel Manufacturer Model Number _____________________________________________ No of Solar PV Panels in Series ____________________________________________________ Note to Installer Record the data...

Page 15: ...e is turned OFF as a result of input from one Mode or more external sensors that are connected to the digital input Over Temperature Pentair Pentek Solar Drive stops operation when the temperature Mod...

Page 16: ...pping charges associated with this warranty and must request warranty service through the installing dealer as soon as a problem is discovered No request for service will be accepted if received after...

Reviews: