background image

©2019 Pentair plc.   I

  

 3

Safety

Important Safety Instructions

SAVE THESE INSTRUCTIONS - This manual 

contains important instructions that should 

be followed during installation, operation, and 

maintenance of the Pentair Pentek Solar Drive.

 This is the safety alert symbol. When you see this 

symbol on your Pentair Pentek Solar Drive or in this 

manual, look for one of the following signal words 

and be alert to the potential for personal injury!

 indicates a hazard which, if not 

avoided, will result in death or serious injury.

 indicates a hazard which, if not 

avoided, could result in death or serious injury.

 indicates a hazard which, if not 

avoided, could result in minor or moderate injury.
NOTICE addresses practices not related to  

personal injury.
Carefully read and follow all safety instructions in 

this manual and on the Pentair Pentek Solar Drive.
Keep safety labels in good condition. Replace 

missing or damaged safety labels.
California Proposition 65 Warning

 This product and related accessories 

contain chemicals known to the State of California 

to cause cancer, birth defects or other reproductive 

harm.

 

Risk of high-voltage electrical shock 

from EMI/RFI filter inside drive. Can shock, burn or 

kill if the front cover of the Pentair Pentek Solar 

Drive is open or removed while power is connected 

to the Drive or the Drive is running. The front cover 

of the Drive must be closed during operation.
•   Make all wiring connections, then close and 

fasten the cover before turning on power to drive.

•  

NEVER open the box when power is connected  

to Drive. 

•   Before doing any service or maintenance inside 

Drive or when connecting or disconnecting any 

wires inside Drive:
1.  DISCONNECT power.
2.  WAIT 5 minutes for retained voltage 

to discharge.

3. Open box.

•   Before starting any wiring or inspection 

procedures, check for residual voltage with a 

voltage tester.

•  

NEVER connect power wiring to Drive before 

mounting the box.

•  

NEVER handle or service Drive with wet or damp 

hands. Always make sure hands are dry before 

working on Drive.

•  

NEVER touch the printed circuit board when 

power is applied to Drive.

 

Risk of fire. Can cause severe injury, 

property damage or death if installed with incorrect 

or inadequate circuit breaker protection. To ensure 

protection in the event of an internal fault in the 

Pentair Pentek Solar Drive, install the Drive on an 

independent branch circuit protected by a circuit 

breaker, with no other appliances on the circuit.

 

Risk of burns. The Drive can become 

hot during normal operation. Allow it to cool for 5 

minutes after shut-down and before handling it to 

avoid burns.
NOTICE To avoid damage to Drive or problems with 

Drive make sure:
•   Drive is correctly wired to the solar source  

and motor load

•   DIP switches are configured to match motor 

specification

•   Drive is installed in the shade away from  

direct sunlight 

•   Do not modify equipment.
•   Do not use power factor correction capacitors  

as they will damage both motor and Pentair 

Pentek Solar Drive.

•   Do not remove any parts unless instructed to  

do so in Owner’s Manual.

•   Do not use a magnetic contactor on Drive for 

frequent starting/stopping.

•   Do not install or operate Drive if it is damaged  

or parts are missing.

•   Before starting Drive that has been in storage, 

always inspect it and test operation.

•   Do not carry out a megger (insulation resistance) 

test on the control circuit of the Drive.

•   Do not allow loose foreign objects which can 

conduct electricity (such as screws and metal 

fragments) inside Drive box at any time. Do not 

allow flammable substances (such as oil) inside 

Drive box at any time.

•   Ground Drive according to the requirements of 

the National Electrical Code Section 250, IEC  

536 Class 1, or the Canadian Electrical Code (as 

applicable) , and any other codes and ordinances 

that apply.

•   All installation, service work, and inspections 

must be done by qualified electrician.

Summary of Contents for Pentek PSD15

Page 1: ...pentair com P1061 03 06 19 INSTALLATIONAND OPERATIONMANUAL SOLARDRIVEPSD15 PENTEK...

Page 2: ...e Installation Requirements 6 Pentair Pentek Solar Drive Hardware 7 Pentair Pentek Solar Drive Overview 8 Pentair Pentek Solar Drive Wiring Instructions 9 Pentair Pentek Solar Drive DIP Switch Setting...

Page 3: ...tage with a voltage tester NEVER connect power wiring to Drive before mounting the box NEVER handle or service Drive with wet or damp hands Always make sure hands are dry before working on Drive NEVER...

Page 4: ...ram for a Pentair Pentek Solar Drive operated solar water pumping system is shown in Figure 1 The solar PV array must be connected to an external DC Disconnect and then to the Pentair Pentek Solar Dri...

Page 5: ...oes not provide branch circuit protection Branch circuit protection must be provided in accordance with the National Electrical Code and any additional local codes ELECTRICAL MECHANICAL Solar PV open...

Page 6: ...n a shaded location away from any source of heat and in an area free of vegetation Measures must also be made to protect the unit from damage by unauthorized persons large animals overgrowth flooding...

Page 7: ...Drive controller should be mounted on a wall or other vertical surface using the back bracket see Figure 5 below On the back side of the unit there are two set screws used to hang the unit on the back...

Page 8: ...e enclosure is open there are three terminal blocks 1 Solar PV wires 2 Motor pump wires 3 Pump or tank sensor wires More information about sensor wiring and DIP switches is provided on page 8 Figure 6...

Page 9: ...ugh the right gland float switch signal wires feed through the middle gland and motor load wires feed through the left gland When all conductors are wired into the controller the cover door should be...

Page 10: ...ed on the motor pump and controller combination being used The default value of RMS current when both switches are OFF is 7A for three phase DIP switches 4 and 5 are to be used to match or exceed the...

Page 11: ...xample of how tank and well switch signals can be used with a digital input port is shown in Figure 10 For a tank application if the active wire is connected to Position 1 and the return wire usually...

Page 12: ...sition All LEDs will light up and after a few seconds the Pentair Pentek Solar Drive will try to start the pump indicated by a blinking green light and upon starting the green LED will remain ON 4 If...

Page 13: ...ugh solar production from the solar panels the yellow LED will start blinking again Shutdown To stop the Pentair Pentek Solar Drive s operation the DC Disconnect should be used Once in the OFF positio...

Page 14: ...PV Panel Manufacturer Model Number _____________________________________________ No of Solar PV Panels in Series ____________________________________________________ Note to Installer Record the data...

Page 15: ...e is turned OFF as a result of input from one Mode or more external sensors that are connected to the digital input Over Temperature Pentair Pentek Solar Drive stops operation when the temperature Mod...

Page 16: ...pping charges associated with this warranty and must request warranty service through the installing dealer as soon as a problem is discovered No request for service will be accepted if received after...

Reviews: