background image

1

WARNING AND IMPORTANT SAFETY INSTRUCTIONS

This symbol indicates that the device uses R32, a 
coolant featuring a low combustion speed.

This symbol indicates that a maintenance technician must handle this 
equipment according to the operating manual.

This symbol indicates that the operating manual 
should be read attentively prior to use.

WARNING: In normal conditions, a suitable HP can heat the water of the pool by 1°C to 2°C per day.
It is therefore quite normal not to feel a temperature difference at the outlet of the circuit when the HP is operating. 
A heated pool should be covered to prevent heat losses.

The appliance is designed to be used in a swimming pool as described in standard NF-EN-16713.
• Failure to comply with the warnings could cause damage to the swimming pool equipment as well as severe injuries or death.
• Only a qualified person possessing the adequate technical skills (electricity, hydraulic, refrigeration) is authorised to undertake maintenance operations or repairs 

on the device. A qualified technician working on the device must use/wear personal protective equipment (safety goggles, protection gloves, etc...) to avoid all risk 
of injury arising during work on the device.

• Prior to any intervention on the device, ensure that it is powered down and has undergone the lockout-tagout procedure.
• The device is designed specifically for use in swimming pools and spas; it must not be used for purposes other than the ones it was designed for.
• This device is not intended for children.
• This device is not intended to be used by persons (including children, of 8 or more) who lack experience or who suffer from physical, sensory, or mental impair-

ment, except;

 –if it is operated under supervision or with operating instructions issued by a person responsible for their safety; and
 –if they understand the risks taken.

• Children must be supervised to ensure that they do not play with the device.
• The installation of the device should be carried out according to the manufacturer’s instructions and in compliance with local and national applicable standards. 

The installer is responsible for the installation of the device and for compliance with national regulations relating to installation procedures. The manufacturer will 
not be liable in case of non-compliance with the installation standards that apply locally.

• For any action other than simple maintenance operations by the user as described in this manual, the product should be maintained by a certified professional.
• Any improper installation and/or use can cause damages and severe injuries (and even death).
• Do not touch the fan or the moving parts, and do not insert objects or your fingers close to the moving parts when the device is operating. • Moving parts can 

cause severe injuries and even death.

• Do not pull on the hoses and the connections to move the machine. 

WARNINGS CONCERNING ELECTRICAL APPLIANCES:

• The power supply of the device must be protected by a 30-mA security residual current protection system, as per the standards that apply in the country of 

installation.

• Do not use an extension to connect the device; only connect the device directly to a suitable power outlet.
• If a fixed device does not feature a power cord and a plug, or any other means to disconnect from the power supply with a separation of the contacts in all the 

poles, enabling total disconnection in case of a category III electrical surge, the manual will mention that the disconnection means must be integrated in the fixed 
wiring, as per relevant wiring rules.

• An adapted disconnection method, complying with all local and national requirements relating to category III electrical surges, and that disconnects all the poles 

of the supply circuit, must be installed in the supply circuit of the device. This disconnection method is not provided with the device and should be provided by 
the installation technician.

• Prior to installation, check that:

 –The voltage featuring on the information plate of the device matches the voltage of the power supply,
 –The power supply is suitable for operating the device and has an earthing connection.
 –The plug (as necessary) adapts to the plughole.

• If the power cord is damaged, it should imperatively be replaced by the manufacturer, a technician or a person qualified to ensure safety.

WARNINGS RELATING TO DEVICES CONTAINING A COOLANT:

• The coolant R32 is a coolant of category A2L, which is considered as potentially flammable.
• Do not release R32 or R410A fluid into the atmosphere. This fluid is a greenhouse effect fluorinated gas, covered by the Kyoto Protocol, with a global warming 

potential (GWP) = 675 for R32 and 2088 for R410A (European regulation EU 517/2014).

• The device must be stored in a well-ventilated place and kept away from flames.
• Install the unit outdoors. Do not install the unit indoors or in an outdoor area that is closed and poorly ventilated.
• To comply with the relevant standards and regulations in terms of the environment and installation procedures, and in particular with decree Nº 2015-1790 and/

or European regulation EU 517/2014, a search for leaks of the cooling circuit must be conducted at least once a year. This operation should be carried out by a 
certified specialist of cooling devices.

• Please keep and transmit these documents for reference throughout the lifespan of the device. 

Summary of Contents for INVERTEMP IVTP-1M-LT

Page 1: ...CTIONS PLEASE READ AND FOLLOW ALL THE INSTRUCTIONS KEEP THESE INSTRUCTIONS PENTAIR AQUATIC SYSTEMS Rev 12 2021 Download the manual available in EN FR NL DE IT ES PT on www pentairpooleurope com EN IVT...

Page 2: ...LT Max power consumption 2 7 kW Weight 43 kg Product IVTP 8T LT Max power consumption 5 4 kW Weight 88 kg Processing by individuals of electronic appliances reaching the end of their lifespan The cros...

Page 3: ...ere injuries and even death Do not touch the fan or the moving parts and do not insert objects or your fingers close to the moving parts when the device is operating Moving parts can cause severe inju...

Page 4: ...2 98 29 9 dB a C 25 A 3G 6 mm 86 kg 24 2 kW 6 5 4 24 2 7 8 kW 10 8 5 4 16 3 7 8 kW 10 8 8 3 22 8 kW 4 5 4 2 22 8 8 1 kW 6 5 4 2 12 5 8 1 kW 6 5 5 6 12 11 kW 2 81 30 7 dB a C 16 A 5G 2 5mm2 86 kg 27 8...

Page 5: ...k that the pressure reading on the pressure gauge is equal to the pressure mentioned on the box depending on the measured outdoor temperature as different values might indicate a leak The HP should al...

Page 6: ...an area where it would be exposed to oil flammable gases corrosive products and compounds containing sulphur close to equipment operating at high frequencies in a place where snow is likely to accumul...

Page 7: ...n order blue water in red water out A bypass must be installed to facilitate work on the HP Before connecting the PVC pipes to the HP make sure the circuit is clean of any work residue stone soil etc...

Page 8: ...in force in the country where the system is installed Crimping the electric cables on appropriate terminals lugs for the diameter of the selected cable before connecting to the HP is recommended The...

Page 9: ...power supply remote control RS 485 as an option Note your HP can be controlled through a dry contact switch or the Pentair RS 485 bus 1 Remove the access hatch by unscrewing the two screws 2 Use the...

Page 10: ...iltration pump Indicative colour Indicative colour Indicative colour Phase Neutral Earthing Phase Yellow Green Black Phase Phase Neutral Earthing Inlet general power supply 230 V 50Hz Dry contact inpu...

Page 11: ...d intermediate circuit breaker properly insulated and connected to the earthing connection The conditions of installation and use described above have all been met The outdoor temperature is between 0...

Page 12: ...essure in the recommended range When stopped the temperature reading should be close to the temperature of the swimming pool water If the hand shows 0 the device should not be used contact your distri...

Page 13: ...ower and sound level automatically adjust depending on the external temperature and the temperature of your pool water BOOST heating or cooling mode maximum HP power The HP can vary the component spee...

Page 14: ...ctronic card in the device Sensor error water inlet Check that the sensor in question is correct ly connected Sensor error water outlet Sensor error evaporator Sensor error compressor outlet Sensor er...

Page 15: ...an account and log in Follow the account creation instructions 3 Add the heat pump 3 1 Click Add 3 2 Select Large device 3 3 Select Smart Heat Pump BLE WiFi 4 Input the Wi Fi 4 3 Select the desired n...

Page 16: ...er household products might damage the surface of the casing and change its properties The evaporator at the rear of the HP can be cleaned carefully using a soft brush vacuum cleaner just a soft brush...

Page 17: ...AMS Reactor Terminal strip 2 Terminal strip 2 Terminal strip 2 Towards the pump 1kW Dry contact Heating resistance of the evaporator Heating resistance of the compressor Reducer Flow detector Wired co...

Page 18: ...OUT1 OUT3 OUT4 OUT5 OUT6 OUT7 OUT8 OUT9 OUT2 OUT10 OUT11 OUT12 OUT13 L EGND N LP HP COM T1 T2 T3 T4 T5 T6 T7 CN2 t t t t t t E VALVE 3 E VAL 2 5 Heating resistance of the compressor PCB N Terminal st...

Page 19: ...grid of the fan 2 Front panel 3 Fan propeller 4 Fan motor 5 Motor support 6 Frame 7 Left panel 8 Board 1 connector 9 Modbus board 10 Electronic board 11 Cable channel 12 Electric casing 13 Cover for...

Page 20: ...1004 LAUSANNE Switzerland Copyright Limited license unless expressly authorised herein no part of the content of the present document can be reproduced in any form or by any means without the prior wr...