![background image](http://html1.mh-extra.com/html/pentair/intellipool/intellipool_user-manual_1524706009.webp)
7
pH
O.R.P.
Conductivity
2
7
1
Distilled
water
3
4
5
50 cm max.
O.R.P.
Conductivity
pH
3
1
2
1
2
3
4
INTELLIPOOL
®
Water temperature
pH
ORP
Conductivity
P R O B E U N I T
INTELLIPOOL
®
Water temperature
pH
ORP
Conductivity
P R O B E U N I T
Radio
OFF
ON
CON
DU
CT
ORP
pH
+24 V
RS-485
+24 V
RS-485
BUS
BUS
pH
CL
6
INTP-1010B
SB-SE-PRO-002C
S/N
1234ABCD1234ABCD1234ABCD01
QC Passed
Pentair International Sarl
Avenue de Sévelin 18
CH-1004 Lausanne, Switzerland
Mfg Year
Apr-2019
MADE IN ITALY
SCAN
ME
8
Pool ID:
12 345
ID Key:
1A:2B:33:99
INTELLIPOOL
24 V / IP64 / 2.4 W
Probe Unit
The Probe Unit, via its probes, measures the pH, ORP (RedOx), conductivity and water temperature. This information is sent to the Control Center.
The length of cables is voluntarily limited to 50 cm to ensure good probe reading precision.
1: Elastomer cover (Watertight protection)
2: Screw cover (protection against entry of vapours)
3: pH probe (0.5 m cable length)
4: ORP probe (0.5 m cable length)
5: Conductivity probe (0.5 m cable length)
6: Water temperature probe (2 m cable length)
7: Identification tag
8: Pool ID label, access codes to an internet account
Tighten/loosen the probe caps, never push or pull the fitted probe caps of the end
plug
.
The Probe Unit must be installed close to the by-pass (the pH, ORP and Conductivity probes have 50 cm long cables)
1 -In the analysis chamber (recommended, Pentair ref. XXX), install the pH, RedOx and Conductivity probes in accordance with the diagram below. The glass
conductivity probe uses the gasket and the O-ring to ensure a perfect seal. The ORP and pH probes only use the O-ring.
2 - Install the temperature sensor outside of the analysis chamber (see the next page).
3 - Pass the cables through the white strain relief bushing, connect the cables in accordance with the markings, screw the strain relief bushing (see the next page).
Installation and connection of probes
pH/ORP probe canister
Conductivity probe cap
The probe canisters must be filled with
potassium chloride or, failing this, running
water
Probe caps
The cap of the conductivity probe may not
be used for other probes.
with (with screw above) = probe out of the water
without = probe in the water
- Pentair Analysis Chamber
Ref. INTP-HOLD-1.
- The probe cables must not cross the
power cable.
- The hydraulic network must be linked to the earth to prevent the
precision of the probes being altered.
- Limit the flow to fill the bowl (1L)
in 1 minute.
- Assembly of the conductivity probe:
Pass the probe through the screw then, 1 - Slide the O-ring under the
probe holder, 2 - Slide the flat seal under the O-ring, 3 - Lower the
probe and probe holder to the contact, 4 - Screw the holder until a
perfect seal is formed after pressure tests.
- Assembly of pH and ORP probes:
Pass the probe through the screw then, 1 - Slide the O-ring under the
probe holder, 2 - Lower the probe and probe holder to the contact,
3 - Screw the holder until a perfect seal is formed after pressure
tests.