pH
1
2
4
5
6
3
pH value
A TOO HIGH OR LOW pH IRRITATES SKIN
> Ensure that:
- The probe bottle has been removed from the pH probe
- The pH probe was calibrated less than 6 months ago (see p35)
- The pH probe is not dirty
> Manual control:
Add “pH-” or “pH+” product according to the type of pH deviation.
> Automatic control:
Check the correct operation of the material.
pH complies with the alarm
alarm set point values
(Factory setting 6.7 to 7.9)
pH is outside of the
alarm set point values
(
min. and max.
indicating if the value
is too low or too high)
pH value measured
(Display limited between 0 and 9.9)
The pH has reached the maximum alarm value
(Factory setting 6.7, can be modified via the alarm menu see p. 33)
The pH has reached the minimum alarm value
(Factory setting 7.9, can be modified via the alarm menu see p. 33)
The pH is a scale (without any units) measuring the acidity (0 to 7) or the alkalinity (7 to 14) of the pool. The pH is the concentration of the hydrogen
ions. For a swimming pool, the ideal pH which is generally advised is close to 7.3 (to be confirmed by your swimming pool supplier according to
your installation).
The precision of the pH measurement is very closely associated with regular pH probe maintenance. We advise you to check the probe for any
dirt present regularly and to calibrate it before the summer season (see p. 33). The factory set points of the upper and lower pH alarms are 6.7
and 7.9. These values can be modified via alarm mode (see p. 33).
Adding a new radio relay
This RADIO mode makes it possible to add a second radio relay to compensate for difficult situations in terms of radio range (elevation, very long
distances, etc.)
1 - Briefly push RESET (0.5 sec) with a paper clip at the back of the indoor display.
note: Pressing for a long time ( >4 sec until the beep) resets
the alarm values
. > The display then shows “radio”.
2 - Remove the tub by pulling on the tab.
3 - > Place the jumper in OFF position to prevent the temp. ext. values of relay radio No. 1 from being distorted.
4 - Remove the insulating film from the batteries
5 - Reconnect the battery unit
6 - The red led flashes > Replace the tub