GENERAL INFORMATION

ProStop-E Quad provides precision on/off control of individual nozzles along a spray boom, with high flow and low power consumption.  
A CAN bus interface communicates using an ISOBUS compatible protocol for complete individual control of the 4 nozzles per module, 
across the entire spray boom.

PERFORMANCE

 



Operating Pressure……………………………150 PSI (10 bar) max

 



Wetted Components………………………….FKM, Nylon, Stainless Steel, Acetal, PTFE, and EPDM.

INSTALLATION AND OPERATION

MODEL 

"A" PIPE / TUBE SIZE

"B"

"C"

4216N-3404VPSQ

1" Pipe

1.69" [42.8]

3.69" [93.7]

4216N-3406VPSQ

22 mm

1.17" [29.6]

3.69" [93.7]

4216N-3407VPSQ

20 mm

1.17" [29.6]

3.69" [93.7]

4216N-3408VPSQ

25 mm

1.42" [36.1]

3.69" [93.7]

4216N-3403VPSQ

3/4" Pipe

1.42" [36.1]

3.69" [93.7]

4216N-3409VPSQ

28 mm

1.47" [37.5]

3.69" [93.7]

4216N-3404VTPSQ

1" Pipe, Tall Stem

1.69" [42.8]

3.91" [99.3]

CONDITION

PRESSURE DROP

FLOW

1 outlet open

5 psi (0.34 bar)

1.7 GPM (6.4 LPM)

2 outlet open, same side (A/B, C/D)

2.4 GPM (9.1 LPM)

2 outlet open, opposite side (A/C, A/D, B/C, B/D)

3.0 GPM (11.4 LPM) 

3 outlet open

3.6 GPM (13.6 LPM)

4 outlet open

4.0 GPM (15.1 LPM)

DIMENSION CHART

CONDITION

IN-RUSH  CURRENT

NOMINAL ACTUATION CURRENT/TIME

1 valve actuating

1.0 A (50 ms)

300 mA for a total time of 230 ms

2 valve actuating

2.0 A (50 ms)

550 mA for a total time of 240 ms

3 valve actuating

2.8 A (50 ms)

750 mA for a total time of 245 ms

4 valve actuating

3.6 A (50 ms)

950 mA for a total time of 250 ms

POWER REQUIREMENTS

DIMENSION DATA

  

21.1

.83   

  

42.2

1.66   

  

147

5.79   

  

111.2

4.38   

  

42

1.65  

  

71.3

2.81   

  "C"  

  

21.3

.84   

  "A"  

  "B"  

9.5

.37

Summary of Contents for Hypro ProStop-E Quad 4216N-3403VPSQ

Page 1: ...L 3113 10 15 22 PROSTOP E ENGLISH 1 16 QUADNOZZLEBODY pentair com INSTALLATIONAND OPERATIONMANUAL 2022 All Rights Reserved...

Page 2: ...his symbol in this manual look for one of the following signal words and be alert to the potential for personal injury indicates a hazard which if not avoided will result in death or serious injury in...

Page 3: ...42 36 1 3 69 93 7 4216N 3403VPSQ 3 4 Pipe 1 42 36 1 3 69 93 7 4216N 3409VPSQ 28 mm 1 47 37 5 3 69 93 7 4216N 3404VTPSQ 1 Pipe Tall Stem 1 69 42 8 3 91 99 3 CONDITION PRESSURE DROP FLOW 1 outlet open 5...

Page 4: ...tiv Connector 15343999 A tab between terminals D E on the BLU side prevents the cables from being installed backwards Unused connector ports need to be plugged for protection and 120 Ohm resistor is r...

Page 5: ...BLU SIDE E D C B A NO SLOT BETWEEN D E ON GRN SIDE CONNECTOR SIGNAL CABLE COLOR WIRE GAUGE BLU SIDE PIN LOCATIONS GRN SIDE PIN LOCATIONS 12 V RED 14 AWG E A CAN HIGH YELLOW 20 AWG D B ADDRESS LINES G...

Page 6: ...ent to the global address 255 so that all devices on the bus are placed in the mapping mode simultaneously Upon seeing a signal on the address line input the device will initiate an address claim proc...

Page 7: ...request a status response from one Nozzle Body PCM 4 corresponds to the Nozzle Bodies at addresses 150 165 PCM 6 corresponds to addresses 166 181 and so on All devices in the PCM s range will receive...

Page 8: ...device at address 118 8 x 157 173 Byte 4 Bit 3 0 Valve control for device at address 118 8 x 158 174 Bit 7 4 Valve control for device at address 118 8 x 159 175 Byte 5 Bit 3 0 Valve control for device...

Page 9: ...from the Nozzle Body at address 180 the ECU would send the following message The Nozzle Body at address 180 would then send a response message that would look like the following GENERAL COMMANDS MESSA...

Page 10: ...00BAC701h 8 PCM 10 Set devices 198 213 Request response from 199 00BB01C7h 1 PCM 11 Status for device 199 00BCD701h 8 PCM 12 Set devices 214 229 Request response from 215 00BD01D7h 1 PCM 13 Status for...

Page 11: ...Body module at address 150 the ECU would send the following message The Nozzle Body module with firmware version 1 02 would then send a response message that would look like the following MESSAGE BYT...

Page 12: ...with clean water to expel other debris before reattaching valve Prevent subsequent contamination by utilizing or installing line strainers in the boom Loss of communication with task controller Verify...

Page 13: ...TY PART 1 A Kit Stem Bottom Clamp 1 pipe 1 3430 0901 1 B Kit Stem Bottom Clamp 20mm 1 3430 0902 1 C Kit Stem Bottom Clamp 22mm 1 3430 0903 1 D Kit Stem Bottom Clamp 25mm 1 3430 0904 1 E Kit Stem Botto...

Page 14: ...14 L 3113 10 15 22 THIS PAGE HAS BEEN LEFT BLANK INTENTIONALLY...

Page 15: ...ber date of purchase and from whom you purchased your product Hypro may request additional information and may require a sketch to illustrate the problem Contact the appropriate Hypro Service Departme...

Page 16: ...eir respective owners Because we are continuously improving our products and services Pentair reserves the right to change specifications without prior notice Pentair is an equal opportunity employer...

Reviews: