An RMA # will be issued by our Product Return Department in Anoka, MN at 763-422-2211. 
Buyer should have following information available at time of RMA request:
1. 

Complete Model Number, Serial Number and description of damaged unit being 
returned.

2. 

Original Buyer Purchase Order number and date product was received by Buyer.

3. 

Quantity to be returned and a brief description of failure for each unit, if different.

4. 

Contact information of Buyer that must include: name of company, billing and shipping 
address, phone, number, fax number, freight carrier and the name and phone number of 
a Buyer contact who can elaborate on the claimed defect in detail.

5. 

Buyer must provide a Repair Purchase Order number for both warranty and out of 
warranty repairs. The PO will not exceed 50% of a new unit. Buyer will be notified of 
repair charges that exceed approved PO amount.

F. 

All returns to Pentair Equipment Protection must be securely packed, using original cartons if 
possible. All returns must have the RMA number visible on the outside of the carton. Pentair 
Equipment Protection is not responsible for material damaged in transit. Any refrigerant-
bearing Goods must be shipped upright for return.

G. 

Shipping cost for all non-warranty repairs is the responsibility of the sender and must be 
shipped prepaid. Shipping costs for all warranty related repairs will be covered by Pentair 
Equipment Protection provided the goods are returned using a Pentair Equipment Protection 
approved carrier. If after diagnoses the product is determined by Pentair Equipment 
Protection not be covered under warranty, Buyer will be responsible for all shipping charges 
and will be billed accordingly.

H. 

Non-warranty repairs are subject to a $105 minimum analysis fee. If approval is not received 
within 30 days, material will be scrapped and all shipping expenses and corresponding 
analysis fees will be billed to Buyer.

I. 

At Buyer’s request, Failure Analysis can be provided by Pentair Equipment Protection for 
warrantable goods at no charge. Failure analysis for non-warranty repairs are subject to a 
$150 per hour Engineering charge plus any other incurred testing costs.

J. 

All returned merchandise must be sent to the following address: Pentair Equipment 
Protection, 2100 Hoffman Way, Anoka, MN 55303-1745.

K. 

Credit for accepted returns shall be at the original selling price or the current selling price, 
whichever is lower, less the restocking charge indicated as follows:
1. 

Within 60 days of invoice date - 20% of applicable selling price.

2. 

Within 61-120 days of invoice date - 30% of applicable selling price.

3. 

Within 121-180 days of invoice date - 40% of applicable selling price.

4. 

Beyond 180 days - subject to individual review by Pentair Equipment Protection.

If product being returned for credit requires repair or modification, the cost of any labor or 
material necessary to bring product into saleable condition will be deducted from credit. 
Buyer may not take credit against returns without prior written Pentair Equipment Protection 
approval.

LIMITATION OF LIABILITY

PENTAIR EQUIPMENT PROTECTION WILL NOT BE LIABLE UNDER ANY 
CIRCUMSTANCES FOR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES, 
INCLUDING WITHOUT LIMITATION ANY LOST PROFITS OR LABOR COSTS, ARISING 
FROM THE SALE, USE OR INSTALLATION OF THE GOODS, FROM THE GOODS BEING 
INCORPORATED INTO OR BECOMING A COMPONENT OF ANOTHER PRODUCT, FROM 
ANY BREACH OF THIS AGREEMENT OR FROM ANY OTHER CAUSE WHATSOEVER, 
WHETHER BASED ON WARRANTY (EXPRESSED OR IMPLIED) OR OTHERWISE BASED 
ON CONTRACT, OR ON TORT OR OTHER THEORY OF LIABILITY, AND REGARDLESS OF 
ANY ADVICE OR REPRESENTATIONS THAT MAY HAVE BEEN RENDERED BY PENTAIR 
EQUIPMENT PROTECTION CONCERNING THE SALE, USE OR INSTALLATION OF THE 
GOODS.

Summary of Contents for HLTSTAT10C

Page 1: ... 2016 Pentair Equipment Protection 89115889 Rev E P N 89115890 2016 Pentair Equipment Protection 89115889 Rev E P N 89115890 Hazardous Location Heaters Thermostat INSTRUCTION MANUAL ...

Page 2: ...IECEX PTB 07 0054X see www pentairprotect com TABLE OF CONTENTS Application 3 Control Accuracy 3 Technical Data 3 Design Data 3 HLTSTAT Thermostat Nominal Setpoints 3 Explosion Protection 4 Installation Instructions 4 ROUTINE CHECK TESTS 5 Initial Operation 5 Wiring Diagram 7 Maintenance 7 CE Declaration of Conformity 8 WARRANTY 10 RETURN AND REPAIR POLICY 10 LIMITATION OF LIABILITY 11 ...

Page 3: ...uate by 18 F 10 C or more For exact temperature control of an instrument a proportional controller with temperature sensor should be used TECHNICAL DATA DESIGN DATA HLTSTAT10C HLTSTAT20C Rated voltage VAC or VDC 0 400V Maximum Rated Current Amps acc to DIN VDE 0298 10 Temperature Tolerance 5 F 3 C Temperature class T6 Ambient temperature 76 to 140 F 60 to 60 C Maximum permissible operating tempera...

Page 4: ...the connection cable during unpacking and transport Before entering the customer supplied Ex junction box the connection cable must be firmly installed and mechanically protected observing the permissible bending radius of 5 times the outside cable diameter If the connection is made in a hazardous area the connection cable must be connected in a housing that meets the requirements of one of the ty...

Page 5: ...rried out on the installed heating system ɒ Do a Visual inspection to determine if the conditions specified under Installation Instructions are met ɒ Conduct an insulation test INITIAL OPERATION When the routine tests are successfully completed the device can be switched on Spacer Mounting Surface Figure 1 ...

Page 6: ... 2016 Pentair Equipment Protection 6 89115889 Figure 2 Figure 3 ...

Page 7: ...tat Figure 4 MAINTENANCE The thermostat is completely encapsulated in silicone and requires no maintenance Performance and safety tests can be conducted at intervals as determined by the operator in compliance with current regulations Repairs must only be done by the manufacturer In dust hazardous areas applicable requirements of EN 60079 17 and EN 60079 19 must be observed ...

Page 8: ... provision of the following directives ɧɚ ɤɨɬɨɪɭɸ ɪɚɫɩɪɨɫɬɪɚɧɹɟɬɫɹ ɞɚɧɧɨɟ ɡɚɹɜɥɟɧɢɟ ɫɨɨɬɜɟɬɫɬɜɭɟɬ ɫɥɟɞɭɸɳɢɦ ɞɢɪɟɤɬɢɜɚɦ 2014 34 EU ATEX 2006 95 EG LVD 2014 30 EU EMC 2011 65 EU RoHS 2012 19 EU WEEE 2014 34 EU ATEX 2006 95 EC LVD 2014 30 EU EMC 2011 65 EU RoHS 2012 19 EU WEEE 2014 34 EU ATEX 2006 95 EC LVD 2014 30 EU EMC 2011 65 EU RoHS 2012 19 EU WEEE und mit folgenden Normen oder normativen Dokume...

Page 9: ... 2016 Pentair Equipment Protection 89115889 9 NOTES ...

Page 10: ...ir Equipment Protection label affixed to product without written Pentair Equipment Protection approval Pentair Equipment Protection must be notified of a claim in writing not later than fourteen 14 days from the date when Buyer has become aware of such occurrence or where the defect is such that it may cause damage immediately such notice containing a description of how the defect manifests itself...

Page 11: ...is fee If approval is not received within 30 days material will be scrapped and all shipping expenses and corresponding analysis fees will be billed to Buyer I At Buyer s request Failure Analysis can be provided by Pentair Equipment Protection for warrantable goods at no charge Failure analysis for non warranty repairs are subject to a 150 per hour Engineering charge plus any other incurred testin...

Page 12: ... 2016 Pentair Equipment Protection 89115889 Rev E P N 89115890 Pentair Equipment Protection 2100 Hoffman Way Minneapolis MN 55303 USA 1 763 422 2211 1 763 576 3200 PentairProtect com ...

Reviews: