background image

© 2016  Pentair Equipment Protection

- 10 -

89115889

WARRANTY

Pentair Equipment Protection warrants that the Goods manufactured by Pentair Equipment 
Protection will be free from defects in material and workmanship for a period of one (1) 
year from the date of shipment by Pentair Equipment Protection, subject to the following 
conditions and exclusions:

A. 

Conditions. All Goods must be installed and operated according to the following 
specifications:
1. 

Maximum voltage variation no greater than plus or minus 10% of nameplate nominal 
rating;

2. 

Maximum frequency variation no greater than plus or minus 3 Hz of nameplate nominal 
rating;

3. 

Must not exceed minimum and maximum stated temperatures on the nameplate;

4. 

Must not exceed (BTU/Hr) rating, including any heat sink as indicated on the nameplate;

5. 

Refrigerant bearing Goods must not be restarted for a period of one (1) minute after 
intentional or accidental shut-off;

6. 

The filters (if applicable) must be cleaned regularly;

7. 

The Goods and any parts thereof must not be modified, unless prior written 
authorization is received from Pentair Equipment Protection; and

8. 

All Goods must be installed and grounded in accordance with all relevant electrical and 
safety codes, as well as the National Electric Code and OSHA rules and regulations.

9. 

All Goods must be installed in a stationery application, free of vibration.

A violation of any one of these conditions shall render the warranty hereunder void and of no 
effect.

B. 

Exclusions. This warranty shall be void if product is misapplied in any way or:
1. 

Buyer specified product is inappropriate for system or environment in which it is 
operating.

2. 

Goods are not installed in accordance with Pentair Equipment Protection specifications.

3. 

Removal or modification of Pentair Equipment Protection label affixed to product without 
written Pentair Equipment Protection approval.

Pentair Equipment Protection must be notified of a claim in writing not later than fourteen 
(14) days from the date when Buyer has become aware of such occurrence, or where the 
defect is such that it may cause damage, immediately, such notice containing a description of 
how the defect manifests itself. Failure to provide such prompt notice to Pentair Equipment 
Protection shall result in forfeiture of Buyer’s rights under this warranty.

In the event of a warranty claim, Buyer is to return defective goods to Pentair Equipment 
Protection in accordance with Pentair Equipment Protection Return Policy. Warranty period 
for repaired goods remains at 1 year from shipment of original goods. Pentair Equipment 
Protection sole obligation to Buyer under this warranty will be, at Pentair Equipment 
Protection option:

C. 

Repair or replace Pentair Equipment Protection products or parts found to be defective in 
material or workmanship.

D. 

Issue credit for the purchase price paid by Buyer relating to such defective Goods or part.
THIS WARRANTY CONSTITUTES THE ENTIRE WARRANTY WITH RESPECT TO THE 
GOODS AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED, 
INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY AND IMPLIED 
WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.

RETURN AND REPAIR POLICY

Pentair Equipment Protection products that: (i) are made to order, (ii) have been modified by 
Buyer, (ii) have special finishes, or (iv) are determined by Pentair Equipment Protection to 
constitute “custom” products that cannot be returned to stock or resold to other Buyers, will 
not be accepted for return by Pentair Equipment Protection.

All returns require a Return Material Authorization number (RMA #), regardless of reason for 
return, whether it be for warranty or out of warranty repair. Returns without an RMA # will be 
refused by our Receiving Department. An RMA # is valid for 30 days.

Summary of Contents for HLTSTAT10C

Page 1: ... 2016 Pentair Equipment Protection 89115889 Rev E P N 89115890 2016 Pentair Equipment Protection 89115889 Rev E P N 89115890 Hazardous Location Heaters Thermostat INSTRUCTION MANUAL ...

Page 2: ...IECEX PTB 07 0054X see www pentairprotect com TABLE OF CONTENTS Application 3 Control Accuracy 3 Technical Data 3 Design Data 3 HLTSTAT Thermostat Nominal Setpoints 3 Explosion Protection 4 Installation Instructions 4 ROUTINE CHECK TESTS 5 Initial Operation 5 Wiring Diagram 7 Maintenance 7 CE Declaration of Conformity 8 WARRANTY 10 RETURN AND REPAIR POLICY 10 LIMITATION OF LIABILITY 11 ...

Page 3: ...uate by 18 F 10 C or more For exact temperature control of an instrument a proportional controller with temperature sensor should be used TECHNICAL DATA DESIGN DATA HLTSTAT10C HLTSTAT20C Rated voltage VAC or VDC 0 400V Maximum Rated Current Amps acc to DIN VDE 0298 10 Temperature Tolerance 5 F 3 C Temperature class T6 Ambient temperature 76 to 140 F 60 to 60 C Maximum permissible operating tempera...

Page 4: ...the connection cable during unpacking and transport Before entering the customer supplied Ex junction box the connection cable must be firmly installed and mechanically protected observing the permissible bending radius of 5 times the outside cable diameter If the connection is made in a hazardous area the connection cable must be connected in a housing that meets the requirements of one of the ty...

Page 5: ...rried out on the installed heating system ɒ Do a Visual inspection to determine if the conditions specified under Installation Instructions are met ɒ Conduct an insulation test INITIAL OPERATION When the routine tests are successfully completed the device can be switched on Spacer Mounting Surface Figure 1 ...

Page 6: ... 2016 Pentair Equipment Protection 6 89115889 Figure 2 Figure 3 ...

Page 7: ...tat Figure 4 MAINTENANCE The thermostat is completely encapsulated in silicone and requires no maintenance Performance and safety tests can be conducted at intervals as determined by the operator in compliance with current regulations Repairs must only be done by the manufacturer In dust hazardous areas applicable requirements of EN 60079 17 and EN 60079 19 must be observed ...

Page 8: ... provision of the following directives ɧɚ ɤɨɬɨɪɭɸ ɪɚɫɩɪɨɫɬɪɚɧɹɟɬɫɹ ɞɚɧɧɨɟ ɡɚɹɜɥɟɧɢɟ ɫɨɨɬɜɟɬɫɬɜɭɟɬ ɫɥɟɞɭɸɳɢɦ ɞɢɪɟɤɬɢɜɚɦ 2014 34 EU ATEX 2006 95 EG LVD 2014 30 EU EMC 2011 65 EU RoHS 2012 19 EU WEEE 2014 34 EU ATEX 2006 95 EC LVD 2014 30 EU EMC 2011 65 EU RoHS 2012 19 EU WEEE 2014 34 EU ATEX 2006 95 EC LVD 2014 30 EU EMC 2011 65 EU RoHS 2012 19 EU WEEE und mit folgenden Normen oder normativen Dokume...

Page 9: ... 2016 Pentair Equipment Protection 89115889 9 NOTES ...

Page 10: ...ir Equipment Protection label affixed to product without written Pentair Equipment Protection approval Pentair Equipment Protection must be notified of a claim in writing not later than fourteen 14 days from the date when Buyer has become aware of such occurrence or where the defect is such that it may cause damage immediately such notice containing a description of how the defect manifests itself...

Page 11: ...is fee If approval is not received within 30 days material will be scrapped and all shipping expenses and corresponding analysis fees will be billed to Buyer I At Buyer s request Failure Analysis can be provided by Pentair Equipment Protection for warrantable goods at no charge Failure analysis for non warranty repairs are subject to a 150 per hour Engineering charge plus any other incurred testin...

Page 12: ... 2016 Pentair Equipment Protection 89115889 Rev E P N 89115890 Pentair Equipment Protection 2100 Hoffman Way Minneapolis MN 55303 USA 1 763 422 2211 1 763 576 3200 PentairProtect com ...