22
•
FLECK
Model ProFloSXT Downflow Service Manual
Error Codes
NOTE:
Error codes appear on the In Service display.
Error
Code
Probable Cause
Recover and Resetting
[Err 0]
Drive motor is stalled
Unplug the unit from the
power source
[Err 1]
Drive motor is running
continuously
When power is restored to
the unit, the Err _ display
code clears. If the condition
causing the error has not
been resolved the Err _ code
reappears in the four digit
display. Do not attempt to
troubleshoot this problem any
further.
[Err 2]
There have been more
than 99 days since the
last Regeneration. If
the Day of the Week
mode of regeneration
is selected and
days since last
regeneration exceeds
7 days.
Regeneration must occur for
the unit to recover, the display
to clear and the valve to
function normally.
[ 7 - - 5 ]: There have
been more than 7
days since the last
regeneration. All
individual settings (d1,
d2, d3, d4, d5, d6, d7)
are set to 0.
[ 7 - - 5 ]: To recover from
[Err2], the user must initiate
a regeneration or set at least
one individual day to 1.
[Err 3]
Control board memory
failure.
Perform a Master Reset. If the
error returns, do not attempt
to troubleshoot this problem
any further.
Error Display Example
NOTE:
Unit will flash when an error exists.
TROUBLESHOOTING
CONTINUED
Summary of Contents for FLECK PROFLOSXT DOWNFLOW
Page 1: ...www pentairaqua com FLECK MODEL PROFLOSXT DOWNFLOW SERVICE MANUAL...
Page 14: ...14 FLECK Model ProFloSXT Downflow Service Manual CONTROL VALVE ASSEMBLY...
Page 24: ...24 FLECK Model ProFloSXT Downflow Service Manual FLOW DATA INJECTOR DRAW SLOW RINSE RATES...
Page 25: ...FLECK Model ProFloSXT Downflow Service Manual 25 DIMENSIONAL DRAWING...
Page 31: ...FLECK Model ProFloSXT Downflow Service Manual 31...