 Model ProFloSXT Downflow Service Manual

Queueing a Regeneration

1.  Press the Extra Cycle button. The service icon will flash to 

indicate that a regeneration is queued.

2.  To cancel a queued regeneration, press the Extra  

Cycle button.

Regenerating Immediately

Press and hold the Extra Cycle button for five seconds.

TIMER OPERATION

Meter Immediate Control

A meter immediate control measures water usage and 

regenerates the system as soon as the calculated system 

capacity is depleted. The control calculates the system 

capacity by dividing the unit capacity (typically expressed in 

grains/unit volume) by the feedwater hardness and subtracting 

the reserve. Meter Immediate systems generally do not use a 

reserve volume. However, in twin tank systems with soft-water 

regeneration, the reserve capacity should be set to the volume 

of water used during regeneration to prevent hard water 

break-through. A Meter Immediate control will also start a 

regeneration cycle at the programmed regeneration time if a 

number of days equal to the regeneration day override pass 

before water usage depletes the calculated system capacity.

Meter Delayed Control

A Meter Delayed Control measures water usage and 

regenerates the system at the programmed regeneration time 

after the calculated system capacity is depleted. As with Meter 

Immediate systems, the control calculates the system capacity 

by dividing the unit capacity by the feedwater hardness and 

subtracting the reserve. The reserve should be set to insure 

that the system delivers treated water between the time the 

system capacity is depleted and the actual regeneration time. 

A Meter Delayed control will also start a regeneration cycle at 

the programmed regeneration time if a number of days equal 

to the regeneration day override pass before water usage 

depletes the calculated system capacity.

Time Clock Delayed Control

A Time Clock Delayed Control regenerates the system on a 

timed interval. The control will initiate a regeneration cycle 

at the programmed regeneration time when the number of 

days since the last regeneration equals the regeneration day 

override value.

Day of the Week Control

This control regenerates the system on a weekly schedule. 

The schedule is defined in Master Programming by setting 

each day to either “off” or “on.” The control will initiates a 

regeneration cycle on days that have been set to “on” at the 

specified regeneration time.

Control Operation During Regeneration 

During regeneration, the control displays a special regeneration 

display. In this display, the control shows the current regeneration 

step number the valve is advancing to, or has reached, and the 

time remaining in that step. The step number that displays 

flashes until the valve completes driving to this regeneration 

step position. Once all regeneration steps are complete the valve 

returns to service and resumes normal operation.
Pressing the Extra Cycle button during a regeneration cycle 

immediately advances the valve to the next cycle step position 

and resumes normal step timing.

Control Operation During Programming 

The control only enters the Program Mode with the valve in 

service. While in the Program Mode, the control continues 

to operate normally monitoring water usage and keeping all 

displays up to date. Control programming is stored in memory 

permanently, eliminating the need for battery backup power.

Manually Initiating a Regeneration

1.  When timer is in service, press the Extra Cycle button for 5 

seconds on the main screen.

2.  The timer advances to Regeneration Cycle Step #1 

(backwash), and begins programmed time count down.

3.  Press the Extra Cycle button once to advance valve to 

Regeneration Cycle Step #2 (brine draw & slow rinse).

4.  Press the Extra Cycle button once to advance valve to 

Regeneration Cycle Step #3 (rapid rinse).

5.  Press the Extra Cycle button once to advance valve to 

Regeneration Cycle Step #4 (brine refill).

6.  Press the Extra Cycle button once more to advance the 

valve back to in service.

NOTE:   

If the unit is a filter or upflow, the cycle step order 

may change.

NOTE:   

A queued regeneration can be initiated by 

pressing the Extra Cycle button. To clear a queued 

regeneration, press the Extra Cycle button again 

to cancel. If regeneration occurs for any reason 

prior to the delayed regeneration time, the manual 

regeneration request shall be cleared.

Control Operation During A Power Failure 

The SXT includes integral power backup. In the event of power 

failure, the control shifts into a power-saving mode. The 

control stops monitoring water usage, and the display and 

motor shut down, but it continues to keep track of the time and 

day for a minimum of 48 hours.
The system configuration settings are stored in a non-volatile 

memory and are stored indefinitely with or without line power. 

The Time of Day flashes when there has been a power failure. 

Press any button to stop the Time of Day from flashing.
If power fails while the unit is in regeneration, the control will 

save the current valve position before it shuts down. When 

power is restored, the control will resume the regeneration 

cycle from the point where power failed. Note that if power 

fails during a regeneration cycle, the valve will remain in it’s 

current position until power is restored. The valve system 

should include all required safety components to prevent 

overflows resulting from a power failure during regeneration. 
The control will not start a new regeneration cycle without 

line power. If the valve misses a scheduled regeneration due 

to a power failure, it will queue a regeneration. Once power 

is restored, the control will initiate a regeneration cycle 

the next time that the Time of Day equals the programmed 

regeneration time. Typically, this means that the valve will 

regenerate one day after it was originally scheduled. If the 

treated water output is important and power interruptions are 

expected, the system should be setup with a sufficient reserve 

capacity to compensate for regeneration delays.

TIMER FEATURES 

CONTINUED

Summary of Contents for FLECK PROFLOSXT DOWNFLOW

Page 1: ...www pentairaqua com FLECK MODEL PROFLOSXT DOWNFLOW SERVICE MANUAL...

Page 2: ...mbing professional This unit is designed to be installed on potable water systems only This product must be installed in compliance with all state and municipal plumbing and electrical codes Permits m...

Page 3: ...low A Downflow B Upflow C Upflow Variable 3 Meter Size A 3 4 inch Elec Paddlewheel B 3 4 inch Elec Turbine 4 System Type A System 4 1 Tank 1 Meter Immediate or Delayed Regeneration B System 4 Time Clo...

Page 4: ...for cutting height of the distributor tube If there is no dimensional drawing cut the distributor tube flush with the top of the tank 5 Lubricate the distributor o ring seal and tank o ring seal Plac...

Page 5: ...Indicator Service Icon Programming Icon Extra Cycle Button Up Button Down Button Error Information Icon Features of the SXT Power backup that continues to keep time and the passage of days for a minim...

Page 6: ...the Extra Cycle button during a regeneration cycle immediately advances the valve to the next cycle step position and resumes normal step timing Control Operation During Programming The control only...

Page 7: ...ty Factor Percentage of the system capacity to be used as a reserve RC Fixed Reserve Capacity Fixed volume to be used as a reserve DO Day Override The system s day override setting RT Regen Time The t...

Page 8: ...entering Master Programming Mode The Display Format setting specifies the unit of measure that will be used for volume and how the control will display the Time of Day This option setting is identifi...

Page 9: ...ING MODE CONTINUED 9 Safety Factor Display Code SF Press the Extra Cycle button Use this display to set the Safety Factor This setting specifies what percentage of the system capacity will be held as...

Page 10: ...on for each day Use the Up and Down buttons to adjust the setting as needed Press the Extra Cycle button to accept the setting and move to the next day Note that the control requires at least one day...

Page 11: ...s while in service and the time of day is NOT set to 12 01 PM 2 Use this display to adjust the Day Override This option setting is identified by DO in the upper left hand corner of the screen 3 Press...

Page 12: ...in service 2 Press the Up button Use this display to view the current Flow Rate This option setting is identified by FR in the upper left hand corner of the screen 3 Press the Up button Use this displ...

Page 13: ...42637 LABEL DISPLAY SXT 8 1 18260 COVER FRONT 9 1 19927 CAM D F SXT 10 1 18211 01 GEAR MAIN DOWNFLOW MACHD 11 1 18228 CAM BRINE VALVE 12 1 18202 BACK PLATE 13 1 40251 MOTOR 24v 50 60hz 14 2 13602 SCRE...

Page 14: ...14 FLECK Model ProFloSXT Downflow Service Manual CONTROL VALVE ASSEMBLY...

Page 15: ...lug Injector 27 2 13771 O ring 012 28 1 18275 X Throat Injector specify size 000 00 0 1 2 3 29 1 18274 X Nozzle Injector specify size 000 00 0 1 2 3 30 1 18273 Vortex Generator 31 1 18271 Screen Injec...

Page 16: ...2 19569 Clip Flow Meter 3 1 19797 Meter Body Assembly 3 4 inch Turbine 4 4 13305 O ring 119 5 1 19791 01 Harness Assembly Flow Meter 1 19791 02 Meter Cable Assy 35 inch 6 19797 Meter 3 4 Turbine No C...

Page 17: ...4 inch NPT Plastic 4B 1 13708 40 Yoke 1 inch Sweat 13708 45 Yoke 3 4 inch Sweat 19275 Yoke Angle 90 Deg 3 4 inch NPT 19275 45 Yoke Angle 90 Deg 3 4 inch Sweat 19620 01 Yoke Assy 3 4 inch R Angle 90 De...

Page 18: ...11978 Plate Bypass Top 5 1 13604 01 Label Bypass Standard Mount 6 8 15727 Screw Hex Wsh Hd 10 24 x 1 2 7 1 11986 Plate Bypass Bottom For Service Assembly Numbers See the Back of this Manual 8 1 11979...

Page 19: ...0 Fitting Sleeve 3 8 Celcon 7 1 10329 Fitting Tube 3 8 Nut Brass 8 1 10186 Nut Hex 10 32 9 1 60002 34 Air Check 500 34 inch Long 60003 34 Air Check 500 HW 34 inch Tube 10 1 10149 Rod Float 11 1 10700...

Page 20: ...24 Nylon Black 5 1 19652 01 Poppet Assy SBV w O ring 6 1 19649 Flow Dispenser 7 1 11183 O ring 017 8 1 19647 Elbow Safety Brine Valve For Service Assembly Numbers See the Back of this Manual 9 2 19625...

Page 21: ...e A Air in water system A Assure that well system has proper air eliminator control Check for dry well condition B Improperly sized drain line flow control B Check for proper drain rate 6 Iron in cond...

Page 22: ...e been more than 99 days since the last Regeneration If the Day of the Week mode of regeneration is selected and days since last regeneration exceeds 7 days Regeneration must occur for the unit to rec...

Page 23: ...FLECK Model ProFloSXT Downflow Service Manual 23 WATER CONDITIONER FLOW DIAGRAMS Service Position Backwash Position Brine Slow Rinse Position Rapid Rinse Position Brine Tank Fill Position...

Page 24: ...24 FLECK Model ProFloSXT Downflow Service Manual FLOW DATA INJECTOR DRAW SLOW RINSE RATES...

Page 25: ...FLECK Model ProFloSXT Downflow Service Manual 25 DIMENSIONAL DRAWING...

Page 26: ...LACK ORANGE WT BLK BLACK WHITE GREEN BLUE BLUE WHITE BLUE WHITE BLUE PURPLE ORANGE BLACK WT BLK YELLOW BLACK BROWN METER P1 S N N H S VDO P2 N O H PWR H S CB1 50 60 HZ CB1 SXT Timer T1 24V Transformer...

Page 27: ...e control in the Backwash position 9 Plug electrical cord into outlet 10 Set Time Of Day and cycle the control valve manually to assure proper function Make sure control valve is returned to the In Se...

Page 28: ...y builds in the conditioner NOTE Be sure to shut off any bypass line 8 Replace the control valve back cover 9 Follow Injectors Screen Replacement steps 9 12 Meter Replacement To replace meter refer to...

Page 29: ...INCHTUBE 60795 02 DISTRIBUTOR ASSY 1 INCH NARROW RED 008 W 72 INCH TUBE DRAIN LINE FLOW CONTROLS 60705 XX DRAIN LINE FLOW CONTROL FROM 6 7 0 GPM 60706 XX DRAIN LINE FLOW CONTROL W QUICK CONNECT FROM...

Page 30: ...10 1 INCH BSP 13398NP 1 INCH NPT NICKEL PLATED 13398 10NP 1 INCH BSP NICKEL PLATED 18706 1 INCH PLASTIC MNPT 18706 10 1 INCH PLASTIC MBSP 18706 02 3 4 INCH PLASTIC MNPT 18706 12 3 4 INCH PLASTIC MBSP...

Page 31: ...FLECK Model ProFloSXT Downflow Service Manual 31...

Page 32: ...emarks and logos are the property of their respective owners Because we are continuously improving our products and services Pentair reserves the right to change specifications without prior notice Pe...

Reviews: