13. Regeneration Cycle Step Times
Press the Extra Cycle button. Use this display to set the
Regeneration Cycle Step Times. The different regeneration
cycles are listed in sequence based on the valve type selected
for the system, and are identified by an abbreviation in the
upper left-hand corner of the screen. The abbreviations used
are listed below. If the system has been configured with the
“OTHER” valve type, the regeneration cycles will be identified
as R1, R2, R3, R4, R5, and R6. Each cycle step time can be
set from 0 to 199 minutes, or “OFF.” Setting a cycle step to
“OFF” will disable all of the following steps. Setting a cycle
step time to 0 will cause the control to skip that step during
regeneration, but keeps the following steps available. Use the
Up and Down buttons to adjust the value as needed. Press the
Extra Cycle button to accept the current setting and move to
the next parameter.
Cycle Step
Abbreviation
BD
Brine Draw
BF
Brine Fill
BW
Backwash
RR
Rapid Rinse
SV
Service
Range: 0-199 minutes
14. Day of Week Settings
Press the Extra Cycle button. Use this display to set the
regeneration schedule for a system configured as a Day of
Week control. The different days of the week are identified as
D1, D2, D3, D4, D5, D6, and D7 in the upper left-hand corner of
the display. Set the value to “ON” to schedule a regeneration
or “OFF” to skip regeneration for each day. Use the Up and
Down buttons to adjust the setting as needed. Press the Extra
Cycle button to accept the setting and move to the next day.
Note that the control requires at least one day to be set to
“ON.” If all 7 days are set to “OFF”, the unit will return to Day
One until one or more days are set to “ON.”
15. Current Day (Display Code CD)
Press the Extra Cycle button. Use this display to set the
current day on systems that have been configured as Day of
Week controls. This setting is identified by “CD” in the upper
left-hand corner of the screen. Use the Up and Down buttons
to select from Day 1 through Day 7.
MASTER PROGRAMMING MODE
CONTINUED
16. Flow Meter Type (Display Code FM)
Press the Extra Cycle button. Use this display to set the type
of flow meter connected to the control. This option setting is
identified by “FM” in the upper left-hand corner of the screen.
Use the Up and Down buttons to select one of the seven
available settings.
t0.7
Fleck 3/4 inch Turbine Meter
P0.7
Fleck 3/4 inch Paddle Wheel Meter
t1.0
Fleck 1 inch Turbine Meter
P1.0
Fleck 1 inch Paddle Wheel Meter
t1.5
Fleck 1-1/2 inch Turbine Meter
P1.5
Fleck 1-1/2 inch Paddle Wheel Meter
GEn
Generic/Other Meter
17. Meter Pulse Setting (Display Code K)
Press the Extra Cycle button. Use this display to specify the
meter pulse setting for a non-standard flow meter. This option
setting is identified by “K” in the upper left-hand corner of
the screen. Use the Up and Down buttons to enter the meter
constant in pulses per unit volume.
18.
Press the Extra Cycle button to save all settings and exit
Master Programming Mode.
Summary of Contents for FLECK PROFLOSXT DOWNFLOW
Page 1: ...www pentairaqua com FLECK MODEL PROFLOSXT DOWNFLOW SERVICE MANUAL...
Page 14: ...14 FLECK Model ProFloSXT Downflow Service Manual CONTROL VALVE ASSEMBLY...
Page 24: ...24 FLECK Model ProFloSXT Downflow Service Manual FLOW DATA INJECTOR DRAW SLOW RINSE RATES...
Page 25: ...FLECK Model ProFloSXT Downflow Service Manual 25 DIMENSIONAL DRAWING...
Page 31: ...FLECK Model ProFloSXT Downflow Service Manual 31...