Installer manual Fleck 2850 SXT - Maintenance
Ref. MKT-IM-030 / C - 12.05.2020
71 / 104
9.2
Recommended maintenance plan
9.2.1
Valve used for softening
Items
1 year
2 year
3 year
4 year
5 year
Injector & filter
Clean
Clean
Clean
Clean
Clean/ replace
if necessary
BLFC***
Clean
Clean
Clean
Clean
Clean/ replace
if necessary
DLFC***
Clean
Clean
Clean
Clean
Clean/ replace
if necessary
Bypass (if
present,
contains
Orings***)
Clean
Clean
Clean
Clean
Clean/replace
if necessary
Piston*
Check/clean/
replace if
necessary
Replace
Check/clean/
replace if
necessary
Replace
Check/clean/
replace if
necessary
Seals &
spacers*
Check/clean/
replace if
necessary
Replace
Check/clean/
replace if
necessary
Replace
Check/clean/
replace if
necessary
Brine valve
Check/clean/
replace if
necessary
Check/clean/
replace if
necessary
Check/clean/
replace if
necessary
Check/clean/
replace if
necessary
Replace
O-rings***
Check for
watertightness
/clean or
replace in case
of leakage
Check for
watertightness
/clean or
replace in case
of leakage
Check for
watertightness
/clean or
replace in case
of leakage
Check for
watertightness
/clean or
replace in case
of leakage
Check for
watertightness
/clean or
replace in case
of leakage
Motors
Check
Check
Check
Check
Replace
Gearing
Check
Check
Check
Check
Check/ replace
if necessary
Inlet hardness
Check
Check
Check
Check
Check
Residual
hardness
Check/adapt
mixing screw if
necessary
Check/adapt
mixing screw if
necessary
Check/adapt
mixing screw if
necessary
Check/adapt
mixing screw if
necessary
Check/adapt
mixing screw if
necessary
Electronic/
settings**
Check
Check
Check
Check
Check/ replace
if necessary
Transformer**
Check
Check
Check
Check
Check/ replace
if necessary
Microswitches
Check
Check
Check
Check
Replace
Meter(s)*
(if present)
Check and
Clean
Check and
Clean
Check and
Clean
Check and
Clean
Replace
Meter cable(s)*
(if present)
Check
Check
Check
Check
Replace