Installer manual Fleck 2850 SXT - Programming
58 / 104
Ref. MKT-IM-030 / C - 12.05.2020
6.5.10.2
Reserve capacity (RC)
Info
This parameter is not shown if RS is set to SF.
The fixed reserve capacity can be set up to a volume equivalent to 50% of the initial
volumetric capacity.
1. Press
or
to set the reserve type.
2. Press
to validate the selection and move to the next parameter.
6.5.11
Days override (DO)
Set the maximum number of days between regeneration cycles.
Info
This parameter allows setting the maximum amount of days that the system can stay in
service mode without regeneration.
Mandatory
In time clock mode, this parameter must be set and the controller will need at least one
regeneration day activated.
Setting the parameter to "OFF" disables this function.
The number of days can be set from OFF, or 1 to 99 days.
1. Press
or
to set the days override.
2. Press
to validate the selection and move to the next parameter.
6.5.12
Regeneration time (RT)
Set the regeneration time.
Info
Regeneration time is the time of the day when regenerations occur for delayed
regeneration of any type and calendar override regeneration.
1. Press
or
to set the regeneration time.
2. Press
to validate the selection and move to the next parameter.