Installer manual Evolio 255 740-760 - Description
Ref. MKT-IM-037 / D - 25.10.2021
23 / 90
3.5
Softener's available options
3.5.1
Chlorine generator and check salt led
The Evolio 255 controller has the capability to produce a low level of chlorine to chlorinate the
resin bed during regeneration. A check salt light will indicate when the user needs to add salt to
the brine tank. Potassium chloride or sodium chloride may be used.
1. Unplug the wall-mounted transformer.
2. Shut off water supply or put bypass valve(s) into bypass position.
3. Relieve system pressure before performing any operations.
4. Remove the softener’s and valve’s covers, see Covers removal (softener and valve)
5. Remove the existing refill controller (1) with the ball (2) from the valve and replace it with the
one (3) provided in the kit (P/N 1244336).
6. Connect the end of the cable (P/N 1206065) to the refill controller previously installed.
Connect firmly to ensure a good contact.
7. Reverse above procedure steps to rebuild.
CAUTION
No programming is necessary for the chlorine generator to work properly on the
controller.
The system will be automatically functional after the chlorine generation senses brine for
the first time. There is a check salt light on the front of the controller that will switch ON
when there is no brine present during the brine draw.
Summary of Contents for Evolio 255 10
Page 1: ...www pentairaquaeurope com INSTALLER MANUAL EVOLIO 255 740 760 RESIDENTIAL ...
Page 64: ...Installer manual Evolio 255 740 760 Maintenance 64 90 Ref MKT IM 037 D 25 10 2021 ...
Page 72: ...Installer manual Evolio 255 740 760 Maintenance 72 90 Ref MKT IM 037 D 25 10 2021 ...
Page 74: ...Installer manual Evolio 255 740 760 Maintenance 74 90 Ref MKT IM 037 D 25 10 2021 ...
Page 78: ...Installer manual Evolio 255 740 760 Maintenance 78 90 Ref MKT IM 037 D 25 10 2021 ...