EASYTOUCH
®
PL4/PSL4 Control Systems Installation Guide
EASYTOUCH
®
PL4/PSL4 Control Systems Installation Guide
29
IntelliFlo Pump
COM Port
COM PORT - J20 connector:
For IntelliFlo
®
Pump, iS4 Spa Side Remote QuickTouch
®
,
PL4/PSl4 Control System Indoor Control
Panel and Pl4/PSL4 Control System
Wireless Controller Transceiver.
5. Strip the leads of the communication cable wires back ¼ in. Insert the wires into the connector
screw terminals (provided in the kit). Using a small flat-blade screwdriver, secure the wires with
the COM PORT (J20) terminal screws. Note: Multiple wires may be inserted into a single screw
terminal. Make sure to match the color-coding of the wires:
GND = Black, Green = -DT, Yellow = +DT, and Red = +15. Connect the screw terminal connector
onto the transceiver circuit board.
6. After electrical connections have be completed; close the Outdoor Control Panel and tighten the
two retaining screws. Reinstall the High Voltage Panel: Insert the panel’s three tabs into the lower
slots on the enclosure. Secure the panel with the two (2) retaining screws. Close the front door and
secure with the latch.
7. After the Power Center is powered up the Wireless Controller will automatically synchronize with the
system iand will be ready for operation.
8. SWITCH ON AC POWER to the Power Center.