CUSTOMIZING THE COMMUNICATION LINK

The communication link between the Receiver and Hand-held Remote can be customized to prevent electrical
interference.  To accomplish this, there is a 10-position configuration switch located on the Receiver circuit board
and inside the Hand-held Remote.  Units are shipped from the factory with all switches in the “ON” position.
If you wish to change this setting, use the corner of a paper clip or other blunt instrument and adjust  both
10-position configuration switches to matching settings. If the configuration switch setting at the Receiver does
not match that of the Hand-held Remote, the communication link will not function.
Labels have been provided, marked with the most commonly used functions. These labels may be affixed to the
side of the Hand-held Remote to assist with button identification.

Receiver

Transmitter

S1

Switch

COMMUNICATION  LINK  ADJUSTMENT

NOTE: All Program Switches are Factory set to “ON”.

Matching Code Example: 

Remote switches 2, 4, 6 “ON”. Receiver switched 2, 4, 6 “ON”.

Affix

Button

ID

Labels

Here

SECTION XII.

TRANSMITTER BATTERY REPLACEMENT

With normal use, the battery should last for several years.  In the event the battery must be replaced, slide the cover
from the bottom of the Hand-held Remote. Slide the battery from the retainer clip and discard in accordance with
local and/or state ordinances.  Replace with 3V lithium battery number CR2032 or equivalent. Slide battery cover
onto remote and snap in place.

Summary of Contents for EASYTOUCH EZ100

Page 1: ...Pentair Pool Products 1620HawkinsAve Sanford NC27330 919 774 4151 10951WestLosAngelesAve Moorpark CA93021 805 523 2400 IMPORTANT The Hand held remote may be used with wet hands but should never be submersed in water as this could damage the unit If accidental submersion occurs dry unit out by removing battery cover and removing battery Position unit so that water can drain out Reassemble when comp...

Page 2: ... of 8 to 10 feet away from any air blower which may be part of the equipment set The Receiver will not operate properly if it is close to a blower which is operating InordertomounttheReceiver itwillbenecessarytoremovethetworetainingscrewslocatedontheundersideof theReceiver andcarefullyslidetheReceivercaseupandoffofitsbackplate Temporarilypositionthebackplate againstitsmountingsurfacesothattheRecei...

Page 3: ...fromSocket 2marked CP100 IfthereisnoIndoorRemote thesilvercableforthereceivermaybe pluggeddirectlyintoSocket 1ofthePowerCentercircuitboard IftheControlSystemincorporatesanIndoor Remote itwillbenecessarytouseaCableSplitterforSocket 1 SeeSECTIONVI CABLESPLITTERS Optional SECTIONVI CABLESPLITTERS Optional IftheControlSystemincorporatesanIndoorRemote disconnectanyexistingIndoorRemotecablesfromSocket 1...

Page 4: ...A4 positionconfigurationswitch designatedS2 whichcanbeusedtoconfigureanautomaticcountdown cyclefortheSpaand orAux1circuit 2 A10 positionconfigurationswitch designatedS1 whichcanbeusedtocustomizethecommunicationlink betweentheReceiverandHand heldRemote 3 2 qty statuslights designatedPOWERandCOMMAND whichareusedfortrouble shooting POWER IndicatesthattheControlSystemissupplyingpowertotheReceiverunit ...

Page 5: ...sedtosetacountdowncycle time outfeature fortheSpaand orAux1circuit Oncethisfeaturehas beenenabled theequipmentwillautomaticallyturnoffafterthecountdowncycleirrespectiveofhowthecircuit wasturnedon byIndoorRemote Spa sideRemoteorHand heldRemote UseapapercliporotherbluntinstrumenttoslidetheappropriateswitchatS2tothe ON or OFF position inaccordancewiththefollowingpictorial ...

Page 6: ... heldRemote thecommunicationlinkwillnotfunction Labelshavebeenprovided markedwiththemostcommonlyusedfunctions Theselabelsmaybeaffixedtothe sideoftheHand heldRemotetoassistwithbuttonidentification Receiver Transmitter S1 Switch COMMUNICATION LINK ADJUSTMENT NOTE All Program Switches are Factory set to ON Matching Code Example Remote switches 2 4 6 ON Receiver switched 2 4 6 ON Affix Button ID Label...

Page 7: ...e Receiver board incorrect circuit Unit fails to operate or fails to Undue electrical noise Relocate the Receiver away from operate dependably at range equipment such as blower motors Too many obstructions between the Relocate the Receiver in a location that Transmitter and Receiver provides fewer obstructions to the area the user commonly operates the Transmitter Receiver unit is too near the gro...

Page 8: ...P N 520041 8 Rev D 2 19 04 Pentair Pool Products 1620HawkinsAve Sanford NC27330 919 774 4151 10951WestLosAngelesAve Moorpark CA93021 805 523 2400 SAVE THESE INSTRUCTIONS ...