background image

P/N

   

520041

2

Rev. D

    2-19-04

SECTION I.

APPLICATION

Used in conjunction with Compool CP100 and EasyTouch Control Systems.

Provides switching of four remote control circuits from a wireless hand-held remote.

It is typically used for activating the spa circulation, and for operating three auxiliary pieces of equipment (such as
lights, jet pump, air blower, waterfall, etc.)

Each of the four functions on the hand-held remote has an “ON” and an “OFF” button.

SECTION II.

KIT INCLUDES:

1-qty. Hand-held Remote (P/N 520018)
1-qty. Receiver (with 8 ft. flexible conduit with 2 –9½ ft. cables inside)
4-qty. Plastic Anchors (for mounting Receiver to a flat surface)
4-qty. Mounting screws (for mounting Receiver to a flat surface)

SECTION III.

RECEIVER

The functional range of the wireless remote (from Hand-held Remote to Receiver) is approximately 150 ft.
line-of-sight.

The Receiver should be mounted at a convenient location (on a flat surface) a minimum of 5 ft. above ground level
to optimize the functional range of the Hand-held Remote.

CAUTION

The Receiver should be mounted a minimum of 8 to 10 feet away from any air blower, which may be part of the

equipment set. The Receiver will not operate properly if it is close to a blower which is operating.

In order to mount the Receiver, it will be necessary to remove the two retaining screws located on the underside of
the Receiver, and carefully slide the Receiver case up and off of its backplate.  Temporarily position the backplate
against its mounting surface so that the Receiver is oriented in an upright position (with antenna pointing upwards,
and flexible conduit protruding from the bottom of the Receiver). The circuit board may need to be temporarily
removed.  Carefully disconnect the modular connectors at the bottom of the circuit board and slide the board out of
the backplate.  Use a pencil to mark the four mounting points. For mounting to stucco walls, drill 3/16 in. dia. holes.
Insert the four plastic anchors (provided). Reposition the backplate over the mounting points and secure with the
four mounting screws (provided).  Carefully slide the circuit board back into the backplate and connect the modular
connectors with the silver cable connector attached to Socket #1 (SILVER) and the black cable connector
attached to Socket #2.  Then slide the Receiver case back onto the backplate, and secure using the two retaining
screws.

Summary of Contents for EASYTOUCH EZ100

Page 1: ...Pentair Pool Products 1620HawkinsAve Sanford NC27330 919 774 4151 10951WestLosAngelesAve Moorpark CA93021 805 523 2400 IMPORTANT The Hand held remote may be used with wet hands but should never be submersed in water as this could damage the unit If accidental submersion occurs dry unit out by removing battery cover and removing battery Position unit so that water can drain out Reassemble when comp...

Page 2: ... of 8 to 10 feet away from any air blower which may be part of the equipment set The Receiver will not operate properly if it is close to a blower which is operating InordertomounttheReceiver itwillbenecessarytoremovethetworetainingscrewslocatedontheundersideof theReceiver andcarefullyslidetheReceivercaseupandoffofitsbackplate Temporarilypositionthebackplate againstitsmountingsurfacesothattheRecei...

Page 3: ...fromSocket 2marked CP100 IfthereisnoIndoorRemote thesilvercableforthereceivermaybe pluggeddirectlyintoSocket 1ofthePowerCentercircuitboard IftheControlSystemincorporatesanIndoor Remote itwillbenecessarytouseaCableSplitterforSocket 1 SeeSECTIONVI CABLESPLITTERS Optional SECTIONVI CABLESPLITTERS Optional IftheControlSystemincorporatesanIndoorRemote disconnectanyexistingIndoorRemotecablesfromSocket 1...

Page 4: ...A4 positionconfigurationswitch designatedS2 whichcanbeusedtoconfigureanautomaticcountdown cyclefortheSpaand orAux1circuit 2 A10 positionconfigurationswitch designatedS1 whichcanbeusedtocustomizethecommunicationlink betweentheReceiverandHand heldRemote 3 2 qty statuslights designatedPOWERandCOMMAND whichareusedfortrouble shooting POWER IndicatesthattheControlSystemissupplyingpowertotheReceiverunit ...

Page 5: ...sedtosetacountdowncycle time outfeature fortheSpaand orAux1circuit Oncethisfeaturehas beenenabled theequipmentwillautomaticallyturnoffafterthecountdowncycleirrespectiveofhowthecircuit wasturnedon byIndoorRemote Spa sideRemoteorHand heldRemote UseapapercliporotherbluntinstrumenttoslidetheappropriateswitchatS2tothe ON or OFF position inaccordancewiththefollowingpictorial ...

Page 6: ... heldRemote thecommunicationlinkwillnotfunction Labelshavebeenprovided markedwiththemostcommonlyusedfunctions Theselabelsmaybeaffixedtothe sideoftheHand heldRemotetoassistwithbuttonidentification Receiver Transmitter S1 Switch COMMUNICATION LINK ADJUSTMENT NOTE All Program Switches are Factory set to ON Matching Code Example Remote switches 2 4 6 ON Receiver switched 2 4 6 ON Affix Button ID Label...

Page 7: ...e Receiver board incorrect circuit Unit fails to operate or fails to Undue electrical noise Relocate the Receiver away from operate dependably at range equipment such as blower motors Too many obstructions between the Relocate the Receiver in a location that Transmitter and Receiver provides fewer obstructions to the area the user commonly operates the Transmitter Receiver unit is too near the gro...

Page 8: ...P N 520041 8 Rev D 2 19 04 Pentair Pool Products 1620HawkinsAve Sanford NC27330 919 774 4151 10951WestLosAngelesAve Moorpark CA93021 805 523 2400 SAVE THESE INSTRUCTIONS ...