32
DISPLAY ICONS 700 CONTROLLER
Rev E
Step 4: Set Regen Time
•
2:00 (AM) is the default time of regeneration. To accept this time, press
the DOWN button to move to step 5.
•
To change the regen time, press SET – causing “2:00” to flash.
•
Use the UP and DOWN buttons to advance to the desired regen time.
•
Press SET to accept the time and advance to the next parameter.
Step 5: Set Days to Regenerate (740 Time-Clock Control Only)
•
If using 760 control – proceed to step 5a.
•
Set number of days between time-clock regeneration (regen frequency).
•
Default time is 3 days.
•
Days can be adjusted from ½ (.5) to 99 days.
•
To change, press SET to make the “3” flash.
•
Use the UP and DOWN buttons to change the number of days desired.
•
Press SET to accept the regen frequency, and advance to the next cycle.
•
To use the 7-day timer option –see
Dealer Installation Manual
.
Step 5a: Set Calendar Override (760 Demand Control Only)
•
If using 740 control – proceed to step 6.
•
Set number of days for calendar override on demand control.
•
“0” days is the default for calendar override.
•
Days can be adjusted from ½ (.5) to 99 days.
•
To change, press SET to make the “0” flash.
•
Use the UP and DOWN buttons to change to the number of days desired.
Press SET to accept the regen frequency, and advance to the next cycle.
Step 6: Amount of Regenerant used per Regeneration
•
Set desired regenerant amount.
•
Default setting is "S" standard salting.
•
3 salt settings are available on 740 and 760 controls:
•
S – Standard Salt – 9 lbs/cubic foot of resin (120 grams/liter of resin)
•
H – High Salt – 15 lbs/cubic foot of resin (200 grams/liter of resin)
•
L – Low Salt – 3 lbs/cubic foot of resin (40 grams/liter of resin)
•
Low Salt is the "Highly Efficient Mode".
•
To change salt setting, press the SET button and use the UP and DOWN
buttons to change to the desired setting.
•
Press SET to accept the setting and advance to the next parameter.
•
See
Dealer Installation Manual
for more complete information on salt
settings for different system sizes, capacities and expected efficiencies.
Time & Day
Regen Time & Day
Salt
SU MO TU
WE TH
FR
SA DAYS
Capacity
Hardness
Time & Day
Regen Time & Day
Salt
SU MO TU
WE TH
FR
SA DAYS
Capacity
Hardness
Time & Day
Regen Time & Day
Salt
SU MO TU
WE TH
FR
SA DAYS
Capacity
Hardness
Time & Day
Regen Time & Day
Salt Amount
SU MO TU
WE TH
FR
SA DAYS
Capacity
Hardness
Time & Day
Regen Time & Day
Salt Amount
SU MO TU
WE TH
FR
SA DAYS
Capacity
Hardness
Time & Day
Regen Time & Day
Salt Amount
SU MO TU
WE TH
FR
SA DAYS
Capacity
Hardness
Standard Setting
High Capacity Setting
Low Setting (High Efficiency)