DISPLAY ICONS 700 CONTROLLER
29
Rev E
Programming Conventions
The 700 Series controller is programmed using the buttons on the keypad.
The programming instructions will be described two ways whenever a section
has keypad input.
First, a table shows simplified instructions. Second, text follows that describes
the action. In each table:
"Action" lists the event or action desired.
"Keys" are listed as:
UP for up arrow
DOWN for down arrow
SET for set
REGEN for regeneration
"Duration" describes how long a button is held down:
P/R for press and release
HOLD for press and hold
X sec for a number of seconds to press the button and hold it down
"Display" calls out the display icons that are visible.
Regeneration Modes
The 700 Series controllers can be regenerated either automatically or
manually. During a regeneration, the total time remaining of the regeneration
will be displayed on the controller. The current cycle is shown in the lower left
of the display.
To Initiate a Manual Regeneration:
•
Press REGEN once for delayed regeneration. System will regenerate at
next set regen time (2:00 AM).
A flashing regen (recycle) symbol will be displayed.
•
Press and hold REGEN for 5 seconds to initiate immediate manual
regeneration. A solid regen symbol will be displayed.
•
After immediate regeneration has begun, press REGEN again to initiate a
second manual regeneration. A flashing "x2" symbol indicates the
second regeneration will start at the time of regeneration. Press and hold
REGEN to turn on the second regeneration immediately following the
current regeneration. The double regeneration is indicated by the "x2"
symbol being on steady.
During a Regeneration:
•
A "C#" is displayed to show current cycle.
•
Total regen time remaining is displayed on screen.
•
Press and hold SET to show current cycle time remaining.
Time & Day
Regen Time & Day
Salt
SU MO TU
WE TH
FR
SA DAYS
C
Capacity
Hardness
MIN
x2
Total regen time remaining