DISPLAY ICONS 700 CONTROLLER
31
Rev E
Initial Start-up Step-By-Step Instructions
For FA filter applications, please program as normal below. See section
Programming the 700 for 5-Cycle Filter Applications
.
Step 1: Program System Size
This step may have been performed by your system’s OEM manufacturer. In
this case, proceed to step 2.
•
Input system size – media volume (For FA filters, choose your closest
media volume) – in cubic feet or liters.
•
Use UP and DOWN buttons to scroll through resin volume choices.
•
Choose the nearest volume to your actual system size.
•
To choose a 3-cycle filter operation – press DOWN until an “F” is
displayed.
•
Press SET to accept the system size you’ve selected.
•
If incorrect setting is programmed, see “Resetting the Control” section
below.
Step 2: Program Time of Day
•
While “12:00” is blinking, set the correct time of day.
•
Use the UP and DOWN buttons to scroll to the correct time of day.
•
“PM” is indicated, “AM” is not indicated.
•
Press SET to accept the correct time of day and advance to the next
parameter.
Step 3: Set Day of Week
•
Press SET to make the arrow under “SU” flash.
•
Use the UP and DOWN buttons to advance the arrow until it is under the
correct day of week.
•
Press SET to accept and advance to the next parameter.
After steps 1-4, the controller will operate most systems. Proceed to
step 4 if further adjustments to your system’s programming is needed.
Time & Day
Regen Time & Day
Salt
SU MO TU
WE TH
FR
SA DAYS
Capacity
Hardness
NOTE:
Capacity is the result of the amount of media in the tank and the
salt setting. The default capacity will be changed by selecting a different
regenerant setting.
Time & Day
Regen Time & Day
Salt
SU MO TU
WE TH
FR
SA DAYS
Capacity
Hardness
3-cycle filter
NOTE:
If the controller was incorrectly set to the wrong valve body, press
the DOWN button and SET button for five seconds to display resin volume
in "HO". Press and hold the SET button for five seconds to reset the
controller. Use the UP or DOWN buttons to increment the display to the
correct valve body. Press SET.
Time & Day
SU MO TU
WE TH
FR
SA DAYS
Capacity
Hardness
Time & Day
Regen Time & Day
Salt
SU MO TU
WE TH
FR
SA DAYS
Capacity
Hardness