7.0  VALVE DIAGNOSIS GUIDE

Problem

Causes

Valve does not close

(Refer to Figure 1)

on start-up with little or

Main valve piston in lift position,

no cargo tank pressure

pressurize dome through field test

handvalve [0.5 to 1.0 kp/cm

2

] to

close piston.

Valve opens at a

Set pressure incorrect

pressure below

nameplate set pressure

Auxiliary setter device incorrect

one for valve.
Auxiliary setter device not screwed

down all the way.
Pilot sense diaphragm leaks. Check

for gas flow through pilot spring

bonnet vent.
Backflow preventer check valve

leaks. (Item 15, Figure 2) Check

for gas flow at discharge tube to

main valve outlet. No gas flow

should be detected.

Valve opens at

Pilot not sensing correct tank pressure

correct pressure

but does not close

Check valve in tank pressure sense

line (Figure 1) restricted.
Filter screen in pilot or small orifices

in pilot restricted.

IMPORTANT

IN AN EMERGENCy, MAIN VALVE

CAN BE CLOSED By PRESSURIZING

DOME (TOP OF PISTON) THROUGH

CLOSE TEE (ITEM 13, FIGURE 2) REMOVE

PLUG (ITEM 18) AND APPLy PRESSURE

EQUAL TO TANK PRESSURE.

8.0  REPAIR KITS

Soft goods

Bolt

Main valve size

kit part number

kit part number

2 x 3

04.4744.810

04.4744.330

3 x 4

04.4744.804

04.4744.331

4 x 6

04.4744.834

04.4744.332

6 x 8

04.4744.835

04.4744.333

Pilot

04.4744.025

04.4744.333

Backflow preventer (diaphragm)

04.4744.781

04.4744.335

Check valve (ball check)

04.4744.782

None

Summary of Contents for ANDERSON GREENWOOD 95 POSRV

Page 1: ...tallation or maintenance of the product or the use of parts or components not manufactured by Anderson Greenwood may result in a failure of the product Any installation maintenance adjustment test etc...

Page 2: ...eck valve Tank pressure sense line Main valve Unbalanced Piston Dome top of the piston Pilot vent Pilot Inlet tank pressure O ring seat Outlet TABLE OF CONTENTS 1 0 General valve description 1 2 0 Acc...

Page 3: ...ighten the body bolts first one side then the opposite side Do not overtighten the bolts as this will distort the diaphragm and cause leakage NOTES 1 Gasket used on some check valves If check valve ha...

Page 4: ...replace the seat The piston seal should not need to be replaced If the piston seal is removed a new seal must be installed The piston can be removed from the cap liner by pulling the piston out or by...

Page 5: ...tightening will damage them Hold the hex spacer when torquing the spindle nut to prevent the stack from rotating After the pilot is assembled the set pressure must be adjusted Refer to Section 5 0 for...

Page 6: ...ANDERSON GREENWOOD TyPE 95 POSRV MAINTENANCE INSTRUCTIONS page 6 ANGMC 6026 US 1312 Copyright 2013 Pentair Engineering Doc 05 9040 083 Rev E Type 95 pilot with auxiliary setter FIGURE 4A...

Page 7: ...ANDERSON GREENWOOD TyPE 95 POSRV MAINTENANCE INSTRUCTIONS Copyright 2013 Pentair ANGMC 6026 US 1312 page 7 Engineering Doc 05 9040 083 Rev E FIGURE 4B...

Page 8: ...e will decrease due to the pressure drop in the lines to the accumulator The set pressure is the highest pressure recorded on the supply pressure gauge 5 3 Decrease the supply pressure to the correct...

Page 9: ...e test gauge Increase the pressure until gas flow at the pilot discharge fitting increases rapidly The pressure at which this occurs is the set pressure of the valve 6 5 To adjust the opening pressure...

Page 10: ...preventer check valve leaks Item 15 Figure 2 Check for gas flow at discharge tube to main valve outlet No gas flow should be detected Valve opens at Pilot not sensing correct tank pressure correct pr...

Reviews: