7.0 VALVE DIAGNOSIS GUIDE
Problem
Causes
Valve does not close
(Refer to Figure 1)
on start-up with little or
Main valve piston in lift position,
no cargo tank pressure
pressurize dome through field test
handvalve [0.5 to 1.0 kp/cm
2
] to
close piston.
Valve opens at a
Set pressure incorrect
pressure below
nameplate set pressure
Auxiliary setter device incorrect
one for valve.
Auxiliary setter device not screwed
down all the way.
Pilot sense diaphragm leaks. Check
for gas flow through pilot spring
bonnet vent.
Backflow preventer check valve
leaks. (Item 15, Figure 2) Check
for gas flow at discharge tube to
main valve outlet. No gas flow
should be detected.
Valve opens at
Pilot not sensing correct tank pressure
correct pressure
but does not close
Check valve in tank pressure sense
line (Figure 1) restricted.
Filter screen in pilot or small orifices
in pilot restricted.
IMPORTANT
IN AN EMERGENCy, MAIN VALVE
CAN BE CLOSED By PRESSURIZING
DOME (TOP OF PISTON) THROUGH
CLOSE TEE (ITEM 13, FIGURE 2) REMOVE
PLUG (ITEM 18) AND APPLy PRESSURE
EQUAL TO TANK PRESSURE.
8.0 REPAIR KITS
Soft goods
Bolt
Main valve size
kit part number
kit part number
2 x 3
04.4744.810
04.4744.330
3 x 4
04.4744.804
04.4744.331
4 x 6
04.4744.834
04.4744.332
6 x 8
04.4744.835
04.4744.333
Pilot
04.4744.025
04.4744.333
Backflow preventer (diaphragm)
04.4744.781
04.4744.335
Check valve (ball check)
04.4744.782
None