TROUBLES-REMEDIES 

A. Pump fails to operate:

1. Check to be sure that power cord is securely plugged into outlet or securely wired 

into controller or switch box. Disconnect power to outlet before handling pump 
or motor.

2. Check to be sure you have electrical power.

3. Check that liquid fluid level is high enough to activate switch or controller.

4. Check to be sure that 5 mm (3/16”) vent hole in discharge pipe is not plugged.

5. Check for blockage in pump inlet, impeller, check valve or discharge pipe.

6. Thermal overload may have tripped. Test start pump; if it starts and then stops 

immediately, disconnect from power source for 30 minutes to allow motor to cool,
then reconnect to power source. Check for cause of overheating/overloading.

B. Pump fails to empty sump:

1. Be sure all valves in discharge valve are fully open.

2. Clean out discharge pipe and check valve.

3. Check for blockage in pump inlet or impeller.

4. Pump not sized properly. A higher capacity pump may be required.

C. Pump will not shut off:

1. Check switch or controller automatic floats for proper operation and location. 

See installation instructions for switch/controller.

2. If pump is completely inoperative or continues to malfunction, consult your 

local serviceman.

Sudden Starts. If power is on to pump

when thermal overload resets, pump may start without
warning. If you are working on pump, you 

may get an electrical shock or impeller may catch
fingers or tools.

Disconnect power before servicing 

pump.

Summary of Contents for 900S Series

Page 1: ...e Can shock burn or cause death During operation the pump is in water To avoid fatal shocks proceed as follows if pump needs servicing 7A Ground pump according to all applicable codes and ordinances 7B Disconnect power to outlet box or circuit breakers before servicing 7C To reduce risk of electric shock take care when changing fuses or resetting circuit breakers Do not stand in water when working...

Page 2: ...0 1 25 15 1 11 2 2 220 50 3 20 12 1 11 2 2 380 50 3 15 8 Operation and Installation NOTICE Do not allow pump to run in a dry sump It will void the warranty and may damage the pump In 1 phase units an automatic overload protector in the motor will protect motor from burning out due to overheating overload ing When motor cools down protector will automatically reset and start motor If overload trips...

Page 3: ...be clean and undamaged or seal may leak 4 Reinstall snap ring on shaft 5 Reassemble impeller washer and impeller screw 6 Install new capacitor single phase See picture below for electrical connections to capacitor 7 Fill motor with clean dielectric oil Part No U197 8A To allow room for expansion oil level with cold motor should be about 1 4 above top of motor assembly 8 Inspect O Ring gasket repla...

Page 4: ...utes to allow motor to cool then reconnect to power source Check for cause of overheating overloading B Pump fails to empty sump 1 Be sure all valves in discharge valve are fully open 2 Clean out discharge pipe and check valve 3 Check for blockage in pump inlet or impeller 4 Pump not sized properly A higher capacity pump may be required C Pump will not shut off 1 Check switch or controller automat...

Reviews: