background image

IMPORTANT PUMP WARNING AND SAFETY INSTRUCTIONS

When installing and using this electrical equipment, basic safety 

precautions should always be followed, include the following:

FAILURE TO FOLLOW ALL INSTRUCTIONS AND 

WARNINGS CAN RESULT IN SERIOUS BODILY 

INJURY OR DEATH. 

THIS PUMP SHOULD BE INSTALLED AND SERVICED 

ONLY BY A QUALIFIED POOL SERVICE PROFESSIONAL. INSTALLERS, 

POOL OPERATORS AND OWNERS MUST READ THESE WARNINGS AND 

ALL INSTRUCTIONS IN THE OWNER’S MANUAL BEFORE USING THIS 

PUMP. THESE WARNINGS AND THE OWNER’S MANUAL MUST BE LEFT 

WITH THE POOL OWNER.

Do not permit children to use this product.

RISK OF ELECTRICAL SHOCK.

 Connect only to 

a branch circuit protected by a ground-fault circuit-

interrupter (GFCI). Contact a qualified electrician if you cannot verify that the 

circuit is protected by a GFCI.

This unit must be connected only to a supply circuit 

that is protected by a ground-fault circuit-interrupter 

(GFCI). Such a GFCI should be provided by the installer and should be 

tested on a  routine basis. To test the GFCI, push the test button. The GFCI 

should interrupt power. Push the reset button. Power should be restored. 

If the GFCI fails to operate in this manner, the GFCI is  defective. If the 

GFCI interrupts power to the pump without the test button being pushed, a 

ground current is flowing, indicating the possibility of an electric shock. Do 

not use this pump. Disconnect the pump and have the problem corrected by 

a qualified service representative before using.

This pump is for use with permanent swimming pools 

and may also be used with hot tubs and spas if so 

marked. Do not use with storable pools. A permanently-installed pool is 

constructed in or on the ground or in a building such that it cannot be readily 

disassembled for storage. A storable pool is constructed so that it is capable 

of being readily disassembled for storage and reassembled to its original 

integrity.

General Warnings

•  Never open the inside of the drive motor enclosure. There is a capacitor 

bank that holds a 230 VAC charge even when there is no power to the 

unit.

•  The pump is not submersible.
•  The pump is capable of high flow rates; use caution when installing and 

programming to limit pumps performance potential with old or questionable 

equipment.

•  Code requirements for electrical connection differ from country to 

country, state to state, as well as local municipalities. Install equipment 

in accordance with the National Electrical Code and all applicable local 

codes and ordinances.

•  Before servicing the pump; switch OFF power to the pump by disconnecting 

the main circuit to the pump.

•  This appliance is not intended for use by persons (including children) of 

reduced physical, sensory or mental capabilities, or lack of experience 

and knowledge, unless they have been given supervision or instruction 

concerning the use of the appliance by a person responsible for their 

safety.

SUCTION ENTRAPMENT HAZARD: STAY OFF 

THE MAIN DRAIN AND AWAY FROM ALL SUCTION 

OUTLETS! 

THIS PUMP IS NOT EQUIPPED WITH SAFETY VACUUM 

RELEASE SYSTEM (SVRS) PROTECTION AND DOES NOT PROTECT 

AGAINST BODY OR LIMB ENTRAPMENTS, DISEMBOWELMENTS (WHEN 

A PERSON SITS ON A BROKEN OR UNCOVERED POOL DRAIN) OR HAIR 

ENTANGLEMENTS.

THIS PUMP PRODUCES HIGH LEVELS OF SUCTION AND CREATES A 

STRONG VACUUM AT THE MAIN DRAIN AT THE BOTTOM OF THE BODY 

OF WATER. THIS SUCTION IS SO STRONG THAT IT CAN TRAP ADULTS 

OR CHILDREN UNDER WATER IF THEY COME IN CLOSE PROXIMITY TO 

A DRAIN OR A LOOSE OR BROKEN DRAIN COVER OR GRATE.
THE USE OF UNAPPROVED COVERS OR ALLOWING USE OF THE POOL 

OR SPA WHEN COVERS ARE MISSING, CRACKED OR BROKEN CAN 

RESULT IN BODY OR LIMB ENTRAPMENT, HAIR ENTANGLEMENT, BODY 

ENTRAPMENT, EVISCERATION AND/OR DEATH.  

The suction at a drain or outlet can cause:
Limb Entrapment:

 When a limb is sucked or inserted into an opening resulting 

in a mechanical bind or swelling. This hazard is present when a drain cover 

is missing, broken, loose, cracked or not properly secured.

Hair Entanglement:

 

When the hair tangles or knots in the drain cover, trapping 

the swimmer underwater. This hazard is present when the flow rating of the 

cover is too small for the pump or pumps.

Body Entrapment: 

When a portion of the body is held against the drain 

cover trapping the swimmer underwater. This hazard is present when the 

drain cover is missing, broken or the cover flow rating is not high enough for 

the pump or pumps.

Evisceration/Disembowelment:

 

When a person sits on an open pool 

(particularly a child wading pool) or spa outlet and suction is applied directly 

to the intestines, causing severe intestinal damage. This hazard is present 

when the drain cover is missing, loose, cracked, or not properly secured.

Mechanical Entrapment: 

When jewelry, swimsuit, hair decorations, finger, 

toe or knuckle is caught in an opening of an outlet or drain cover.  This hazard 

is present when the drain cover is missing, broken, loose, cracked, or not 

properly secured.

NOTE: ALL SUCTION PLUMBING MUST BE INSTALLED IN ACCORDANCE 

WITH THE LATEST NATIONAL AND LOCAL CODES, STANDARDS AND 

GUIDELINES.

This is the safety alert symbol. When you see this 

symbol on your system or in this manual, look for 

one of the following signal words and be alert to the 

potential for personal injury.

Warns about hazards that can cause death, serious 

personal injury, or major property damage if ignored.

Warns about hazards that may cause death, serious 

personal injury, or major property damage if ignored.

Warns about hazards that may or can cause minor 

personal injury or property damage if ignored.

           NOTE

             Indicates special instructions not related to  

   

hazards.

Carefully read and follow all safety instructions in this manual and on 

equipment. Keep safety labels in good condition; replace if missing or 

damaged.

READ AND FOLLOW ALL INSTRUCTIONS

SAVE THESE INSTRUCTIONS

IMPORTANT NOTICE

This guide provides installation and operation instructions for this pump. 

Consult Pentair with any questions regarding this equipment. 

Attention Installer: 

This guide contains important information about the 

installation, operation and safe use of this product. This information should 

be given to the owner and/or operator of this equipment after installation or 

left on or near the pump. 

Attention User: 

This manual contains important information that will help you 

in operating and maintaining this product. Please retain it for future reference.

F

Summary of Contents for 5P6R

Page 1: ...6R6G 212 5P6R6G3 212 3 5P6R6H 213 5P6R6H3 213 This manual should be given to the owner of this pump 2020 Pentair All rights reserved 1620 Hawkins Ave Sanford NC 27330 919 566 8000 10951 West Los Angel...

Page 2: ...NST BODYOR LIMB ENTRAPMENTS DISEMBOWELMENTS WHEN APERSON SITS ONABROKEN OR UNCOVERED POOL DRAIN OR HAIR ENTANGLEMENTS THIS PUMP PRODUCES HIGH LEVELS OF SUCTION AND CREATES A STRONG VACUUM AT THE MAIN...

Page 3: ...S meeting ASME ANSI A112 19 17 Manufactured Safety Vacuum Release systems SVRS for Residential and Commercial Swimming Pool Spa Hot Tub and Wading Pool Suction Systems and or ASTM F2387 Standard Speci...

Page 4: ...d on equipment Keep safety labels in good condition replace if missing or damaged Incorrectly installed or tested equipment may fail causing severe injury or property damage Read and follow instructio...

Page 5: ...pipe To reduce friction losses Allow for gate valves in suction and discharge piping Have adequate floor drainage to prevent flooding Be protected from excess moisture Allow adequate access for servi...

Page 6: ...system must provide protection against the hazard of suction entrapment or hair entrapment entanglement Suction Outlet Covers All suction outlet covers must be maintained They must be replaced if crac...

Page 7: ...e requirements above are met Water Velocity The maximum water velocity through any suction outlet must be 1 5 feet 46cm per second unless the outlet complies with the latest ASME SNSI Specification fo...

Page 8: ...d tight he wires to the appropriate length so they do not overlap or touch when connected Permanently ground the motor using the green ground ty ground wire is connected to an electrical service groun...

Page 9: ...suction and discharge valves are opened If pump is not in a flooded suction system remove trap cover handle ring and trap cover fill trap and pump with water Do not lubricate the trap cover O Ring The...

Page 10: ...tions below Keep motor dry and covered during storage To avoid condensation corrosion problems do not cover pump with plastic For outdoor unprotected installations 1 Gravity drain system as far as pos...

Page 11: ...ntil rubber drive ring hits shoulder NOTICE Be sure not to nick or scratch polished seal face seal will leak if face is damaged 7 Screw impeller onto shaft clockwise this will automatically locate sea...

Page 12: ...logged follow steps 1 through 7 under Removing Old Seal Page 9 check impeller for clogging follow steps 7 through 10 under Installing New Seal Page 9 for reassembly 7 Impeller and diffuser may be worn...

Page 13: ...8 Screw Tank Body BSP Threads Trap Cover Trap O Ring Basket 1 4 NPT Drain Plug Base Washer Base Screw Base Motor Pad 3 8 16 x 1 Hex Head Screw Tag CAUTION WARNING Bonding C63 12 5P6R SERIES 50 Hz MAX...

Page 14: ...19 37A 9 Clamp Knob 1 WC36 22 10 Impeller 1 Chart at Right 10A Impeller O Ring 1 35505 1426 10B Impeller Screw 1 37337 6080 11 Diffuser 1 C1 271P 12 Diffuser O Ring 1 U9 374 13 8 Lock Washer 5 U43 21S...

Page 15: ...1 271P 12 Diffuser O Ring 1 U9 374 13 8 Lock Washer 5 U43 21SS 14 8 32 x 1 1 8 Screw 5 U30 922SS 15 Tank Body BSP Threads 1 17307 0110W 16 Trap Cover 1 17407 0111S 17 Trap O Ring 1 35505 1440 18 Baske...

Page 16: ...the U S A and or other countries Third party registered and unregistered trademarks and logos are the property of their respective owners Because we are continuously improving our products and service...

Reviews: