Pentair 5P6R Installation And User Manual Download Page 12

1

0

TROUBLESHOOTING
GUIDE

Read and understand safety and operating
instructions in this manual before doing any work

on pump!

Only qualified personnel should electrically test
pump motor!

FAILURE TO PUMP; REDUCED CAPACITY OR 
DISCHARGE PRESSURE

Suction leaks/lost prime:

1.

Pump must be primed; make sure that pump volute
and trap are full of water. See priming instructions,
Page 

7.

2.

Make sure there are no leaks in suction piping.

3.

Make sure suction pipe inlet is well below the water
level to prevent pump from sucking air.

4.

Suction lift of 10 to 20 feet (3-6 M) will reduce
performance. Suction lift of more than 20 feet (6 M)
will prevent pumping and cause pump to lose
prime. In either case, move pump closer (vertically)
to water source. Make sure suction pipe is large
enough.

Clogged pipe/trap/impeller, worn impeller:

5.

Make sure suction trap is not clogged; if it is, clean

 

trap and strainer.

6.

Make sure impeller is not clogged (follow steps 1

 

through 7 under “Removing Old Seal”, Page 

9;

 

check impeller for clogging; follow steps 7 through

 

10 under “Installing New Seal”, Page 

9

, for

 

reassembly).

7.

Impeller and diffuser may be worn. If so, order

 

replacement parts from Repair Parts List, Page

11-

1

3

.

8.

Pump may be trying to push too high a column of

 

water. If so, a “higher head” pump is needed.

Electrical:

9. Pump may be running too

slowly; check voltage at
motor terminals and at
meter while pump is
running. If low, see wiring
instructions or consult
power company. Check
for loose connections.

10. Pump may be too hot.

A. Check line voltage; if

less than 90% or more
than 110% of rated
voltage consult a
licensed electrician.

B. Increase ventilation.
C. Reduce ambient

temperature.

D. Tighten any loose connections.

MECHANICAL TROUBLES AND NOISE

1. If suction and discharge piping are not adequately

supported, pump assembly will be strained. See
“Installation”, Page 3.

2. Do not mount pump on a wooden platform! Securely

mount on concrete platform for quietest
performance.

Hazardous voltage.

Can shock, burn,

or cause death.

Disconnect power

before working

on pump or motor.

Summary of Contents for 5P6R

Page 1: ...6R6G 212 5P6R6G3 212 3 5P6R6H 213 5P6R6H3 213 This manual should be given to the owner of this pump 2020 Pentair All rights reserved 1620 Hawkins Ave Sanford NC 27330 919 566 8000 10951 West Los Angel...

Page 2: ...NST BODYOR LIMB ENTRAPMENTS DISEMBOWELMENTS WHEN APERSON SITS ONABROKEN OR UNCOVERED POOL DRAIN OR HAIR ENTANGLEMENTS THIS PUMP PRODUCES HIGH LEVELS OF SUCTION AND CREATES A STRONG VACUUM AT THE MAIN...

Page 3: ...S meeting ASME ANSI A112 19 17 Manufactured Safety Vacuum Release systems SVRS for Residential and Commercial Swimming Pool Spa Hot Tub and Wading Pool Suction Systems and or ASTM F2387 Standard Speci...

Page 4: ...d on equipment Keep safety labels in good condition replace if missing or damaged Incorrectly installed or tested equipment may fail causing severe injury or property damage Read and follow instructio...

Page 5: ...pipe To reduce friction losses Allow for gate valves in suction and discharge piping Have adequate floor drainage to prevent flooding Be protected from excess moisture Allow adequate access for servi...

Page 6: ...system must provide protection against the hazard of suction entrapment or hair entrapment entanglement Suction Outlet Covers All suction outlet covers must be maintained They must be replaced if crac...

Page 7: ...e requirements above are met Water Velocity The maximum water velocity through any suction outlet must be 1 5 feet 46cm per second unless the outlet complies with the latest ASME SNSI Specification fo...

Page 8: ...d tight he wires to the appropriate length so they do not overlap or touch when connected Permanently ground the motor using the green ground ty ground wire is connected to an electrical service groun...

Page 9: ...suction and discharge valves are opened If pump is not in a flooded suction system remove trap cover handle ring and trap cover fill trap and pump with water Do not lubricate the trap cover O Ring The...

Page 10: ...tions below Keep motor dry and covered during storage To avoid condensation corrosion problems do not cover pump with plastic For outdoor unprotected installations 1 Gravity drain system as far as pos...

Page 11: ...ntil rubber drive ring hits shoulder NOTICE Be sure not to nick or scratch polished seal face seal will leak if face is damaged 7 Screw impeller onto shaft clockwise this will automatically locate sea...

Page 12: ...logged follow steps 1 through 7 under Removing Old Seal Page 9 check impeller for clogging follow steps 7 through 10 under Installing New Seal Page 9 for reassembly 7 Impeller and diffuser may be worn...

Page 13: ...8 Screw Tank Body BSP Threads Trap Cover Trap O Ring Basket 1 4 NPT Drain Plug Base Washer Base Screw Base Motor Pad 3 8 16 x 1 Hex Head Screw Tag CAUTION WARNING Bonding C63 12 5P6R SERIES 50 Hz MAX...

Page 14: ...19 37A 9 Clamp Knob 1 WC36 22 10 Impeller 1 Chart at Right 10A Impeller O Ring 1 35505 1426 10B Impeller Screw 1 37337 6080 11 Diffuser 1 C1 271P 12 Diffuser O Ring 1 U9 374 13 8 Lock Washer 5 U43 21S...

Page 15: ...1 271P 12 Diffuser O Ring 1 U9 374 13 8 Lock Washer 5 U43 21SS 14 8 32 x 1 1 8 Screw 5 U30 922SS 15 Tank Body BSP Threads 1 17307 0110W 16 Trap Cover 1 17407 0111S 17 Trap O Ring 1 35505 1440 18 Baske...

Page 16: ...the U S A and or other countries Third party registered and unregistered trademarks and logos are the property of their respective owners Because we are continuously improving our products and service...