5
SHURflo Operating Instructions, Performance,
Specifications and Parts Manual
Viton Models GMSV2A, GMSV4A, GMSV6C, GMSV2A3T, GMSV2A33T,
GMSV4A5T, GMSV4A53T, GMSV6C7T and GMSV6C73T
Teflon
®
Models GMST2A, GMST4A, GMST6C, GMST2A3T, GMST2A33T,
GMST4A5T, GMST4A53T, GMST6C7T and GMST6C73T
Form L-4089 (2/17)
Specifications for Standard Motor-Mounted Models
PUMP CONSTRUCTION (Wet End)
Shaft, O-Rings
AC
Pump
Body &
Keys
&
Ship
Motor Motor NEMA Motor
Motor
Shaft
Motor Motor
Cover
Gear
&
Gasket Seals Wt.
Model
HP Type Frame Voltage* Amps PH** RPM
Size
Shaft Adapter Port*** Casting Material Clips Material **** (lbs.)
Viton Models
GMSV2A3T 3/4 TEFC
56C
115/230 11.2/5.6 1 1725
1/2 Keyed 5/8 Keyed CI
3/8 316 SS
Ryton 316 SS Graphoil Viton
36.9
GMSV2A33T 3/4 TEFC
56C
230/460 2.6/1.3 3 1725
1/2 Keyed 5/8 Keyed CI
3/8 316 SS
Ryton 316 SS Graphoil Viton
35.9
GMSV4A5T 1
1
⁄
2
TEFC
56C
115/230 18.4/9.2 1 1725
5/8 Keyed 5/8 Keyed CI
1/2 316 SS
Ryton 316 SS Graphoil Viton
60.5
GMSV4A53T 1
1
⁄
2
TEFC
56C
3
5/8 Keyed 5/8 Keyed CI
1/2 316 SS
Ryton 1144 Steel Graphoil Viton
53.5
GMSV6C7T
3
TEFC 182/184TC 230
14.7
1 1725 20mm Keyed 1
1
⁄
8
Keyed
CI
1
316 SS
Ryton 316 SS Graphoil Viton 120.1
GMSV6C73T 3
TEFC 182/184TC 230/460 8.2/4.1 3 1725 20mm Keyed 1
1
⁄
8
Keyed
CI
1
316 SS
Ryton 316 SS Graphoil Viton
88.1
Teflon Models
GMST2A3T 3/4 TEFC
56C
115/230 11.2/5.6 1 1725
1/2 Keyed 5/8 Keyed CI
3/8 316 SS
Ryton 316 SS Graphoil Teflon 36.9
GMST2A33T 3/4 TEFC
56C
230/460 2.6/1.3 3 1725
1/2 Keyed 5/8 Keyed CI
3/8 316 SS
Ryton 316 SS Graphoil Teflon 35.9
GMST4A5T 1
1
⁄
2
TEFC
56C
115/230 18.4/9.2 1 1725
5/8 Keyed 5/8 Keyed CI
1/2 316 SS
Ryton 316 SS Graphoil Teflon 60.5
GMST4A53T 1
1
⁄
2
TEFC
56C
3
5/8 Keyed 5/8 Keyed CI
1/2 316 SS
Ryton 1144 Steel Graphoil Teflon 53.5
GMST6C7T
3
TEFC 182/184TC 230
14.7
1 1725 20mm Keyed 1
1
⁄
8
Keyed
CI
1
316 SS
Ryton 316 SS Graphoil Teflon 120.1
GMST6C73T 3
TEFC 182/184TC 230/460 8.2/4.1 3 1725 20mm Keyed 1
1
⁄
8
Keyed
CI
1
316 SS
Ryton 316 SS Graphoil Teflon 88.1
SS = Stainless Steel CI = Cast Iron CG = Carbon Graphite Ryton = PPS (Polyphenylene Sulfide) TEFC = Totally-Enclosed Fan-Cooled Motor
(*) Motors are rated at 60 hertz only.
(**) Single-phase motors are thermally overload protected (reset may be automatic or manual); 3-phase motors are not thermally protected.
(***) Female NPT inlet and outlet (in inches).
(****) Standard Shaft Seals have carbon on ceramic faces and 316 SS components.
NOTE: Driver data is subject to change without notice; see label on driver for specifications and wiring information.
Manufacturer reserves the right to change specifications without notification.
230/460
190/380
230/460
190/380
4.8/2.4
5/2.5
4.8/2.4
5/2.5
1750
1450
1750
1450