background image

Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting to assemble, install, 
operate or maintain the product described. Protect yourself and others by observing all safety information. The Safety Instructions are contained in the 
General Operating Instructions. Failure to comply with the safety instructions accompanying this product could result in personal injury and/or property  
damage! Retain instructions for future reference.

SHURflo Operating Instructions, Performance, 

Specifications and Parts Manual

Form L-4089 (2/17) 

SHURflo 316 Stainless Steel Rotary 

Close-Coupled External Gear Pumps

Description

SHURflo self-priming, positive displacement, external rotary gear pumps operate bi-directionally (reversible) and provide a  
nearly pulseless flow for a wide range of industrial, marine, agricultural, and commercial chemical-duty applications. Mounted 
directly to NEMA frame AC Totally-Enclosed Fan-Cooled (TEFC) motors using an easy-installation package, or as pump heads  
only for custom installations. Single-phase motors are thermally overload protected; 3-phase motors are not. Ryton PPS 
(Polyphenylene Sulfide) spur gears provide quiet operation and chemical compatibility with no metal-to-metal contact.  
Pumps can operate in a temperature range of 32° to 280° F.  
Quality features include a keyed 316 stainless steel shaft supported by a ball bearing and carbon graphite bushings. Wet-end 
parts are constructed of 316 stainless steel, Ryton PPS, graphite, graphoil, carbon, ceramic, and Viton or Teflon

®

.

Uses: For use with non-particulate and non-abrasive fluids compatible with pump wet-end construction component materials.
•  Capacities up to 24.8 GPM.
•  Maximum pressure to 125 PSI and working casing pressure to 200 PSI.
•  Max. RPM: 1725.
•  Suction lift to 19.5 ft.
•  Temperature ranges from 32° to 280° F.
•  Large female NPT ports allow use with viscous fluids.
•  Pumps are close-coupled with electric motors to handle up to 500 SSU at 1725 RPM or run at reduced speeds to handle  

a wide range of pump fluid viscosities and specific gravity up to 100,000 SSU. (Maximum torque loads are found in the  
performance chart.)

•  Viton or Teflon

®

 mechanical seals (standard) with carbon on ceramic faces with engineered flush chamber for internal or  

external flush to handle viscosities beyond 2000 SSU.

•  Pumps can operate bi-directionally (reversible).
REPAIR SEALS AND OPTIONS – Standard seals are Viton or Teflon

® 

(Buna-N is optional) with carbon on ceramic faces. Seals can be 

located in the repair parts list pages in the owner’s manual. When switching between standard and optional mechanical seals, be 
sure to order the matching o-rings in the same material. These can be found in the repair parts list pages of this manual. 
Optional Close-Coupled Gear Speed Reducers are available that mount directly between pump and motor to reduce pump speed 
for high viscosity or high specific gravity applications (See Appendix 2). 
NOTE: This series of gear pumps is also available as pedestal models for custom applications.

WARNING:  Do not use to pump flammable or explosive fluids such as gasoline, fuel oil, kerosene, etc. Do not use in flammable 
and/or explosive atmospheres. When pumping hazardous or dangerous materials, use only in a room or area designated for that 
purpose. For your protection, always wear proper clothing, eye protection, etc. in case of any malfunction. For proper handling tech-

niques and cautions, contact your chemical supplier, insurance company and local agencies (fire dept., etc.). Failure to comply with this warn-
ing could result in personal injury and/or property damage.

Viton Models GMSV2A, GMSV4A, GMSV6C, GMSV2A3T, GMSV2A33T, 

GMSV4A5T, GMSV4A53T, GMSV6C7T and GMSV6C73T 

Teflon

®

 Models GMST2A, GMST4A, GMST6C, GMST2A3T, GMST2A33T, 

GMST4A5T, GMST4A53T, GMST6C7T and GMST6C73T 

Refer to form L-4082 for General Operating and Safety Instructions and Applicable Warranty.

Summary of Contents for SHURflo Teflon GMST2A

Page 1: ...32 to 280 F Large female NPT ports allow use with viscous fluids Pumps are close coupled with electric motors to handle up to 500 SSU at 1725 RPM or run at reduced speeds to handle a wide range of pum...

Page 2: ...5TC C 182 184TC 1 1 3 2 1 2 3 3 4 4 1 5 11 2 6 2 7 3 Blank no code single phase ODP motor 3 3 phase ODP motor T 1 phase TEFC 3T 3 phase TEFC 1st 2nd 3rd 4th 5th 6th 7th Mounting Material Seal Gear Mot...

Page 3: ...e pump and possibly a larger motor should be selected Manufacturer reserves the right to change performance without notification Performance with Water 3 Form L 4089 2 17 Performance with Oil Viton Te...

Page 4: ...6 SS Ryton PPS 316 SS Graphoil Viton 8 9 GMSV4A 56C 1725 5 8 Keyed 5 8 Keyed CI 1 2 316 SS Ryton PPS 316 SS Graphoil Viton 17 5 GMSV6C 182 184TC 1725 20mm Keyed 11 8 Keyed CI 1 316 SS Ryton PPS 316 SS...

Page 5: ...ed CI 1 316 SS Ryton 316 SS Graphoil Viton 88 1 Teflon Models GMST2A3T 3 4 TEFC 56C 115 230 11 2 5 6 1 1725 1 2 Keyed 5 8 Keyed CI 3 8 316 SS Ryton 316 SS Graphoil Teflon 36 9 GMST2A33T 3 4 TEFC 56C 2...

Page 6: ...6 67 1 8 2 85 3 50 4 91 6 32 21 73 6 59 3 00 6 50 2 63 4 88 3 00 0 34 GMST2A GMST2A3T GMST2A33T GMSV4A GMSV4A5T GMSV4A53T 1 2 4 50 4 90 9 35 7 46 1 8 2 75 3 50 5 00 6 32 25 12 6 59 3 50 6 50 2 63 4 8...

Page 7: ...proximately 1 8 The other coupling half must be installed on the motor shaft To do this it should be placed on the shaft with the key with the shaft recessed approximately 1 2 The set screw is not yet...

Page 8: ...harge outlet Support pump and piping during assembly and after installation Failure to do so may cause piping to break pump to fail motor bearing failures etc all of which can result in property damag...

Page 9: ...s for operating tempera tures above 120 F will result in severe pump and or motor damage NOTE When pumping fluids of high viscosity 500 ssu the required torque and HP can be reduced by adding a gasket...

Page 10: ...is regulated into the seal cavity by means of a needle valve and flow meter Use of an anti siphon check valve is required Operation Continued It is essential that an anti siphon check valve be install...

Page 11: ...nstalled elec tric motors are capable of operating for years with minimal maintenance Periodically clean dirt accumulations from open type motors especially in and around vent openings preferably by v...

Page 12: ...wo styles one has a rubber boot and the other has an o ring Identify which type you have See Figure 10 For the Teflon seal see the following note and Figure 12 c Refer to assembling components on driv...

Page 13: ...4089 2 17 Figure 13 Repair Parts Illustration Please provide following information Model number Serial number if any Part description and number as shown in parts list To order parts contact a SHURfl...

Page 14: ...22362 22362 4 23 Coupling 21885 21886 22184 21885 21886 22184 1 24 Cap Screw 13309 13309 13309 13309 13309 13309 4 25 Anti Rotation Pin NA NA NA 22537 22537 22537 1 26 Motor 3 4 HP 1 PH TEFC 21594S O...

Page 15: ...mark proper orientation of cover and pump body 4 Replace gaskets 3 per instructions listed in table 5 Replace cover 2 and cover screws 1 according to orientation marked in step 3 6 Tighten cover scre...

Page 16: ...1200 Gear Reducer 145TC to 145TC 1 5 ratio 5 625 2 875 1167 29 AGR184TC600 Gear Reducer 184TC to 184TC 3 0 ratio 7 43 2 875 583 56 AGR184TC900 Gear Reducer 184TC to 184TC 2 0 ratio 7 43 2 875 875 56 A...