6.4 ERROR TABLE
MESS
DISPLAY
DESCRIPTION ACTION
E00
No event
The error log appears when no
errors have been signalled
-
E01
Generic fault (in
memory)
This error occurs in the presence
of:
x
Internal module error
x
Overheating of the power
module
x
Pump failure
Press the START/STOP button to
attempt to exit this condition. In
case of a persistent error, contact
technical support.
E02
Temporary external
error
An external error occurs when
there is a problem with the power
module. The module will not be
operative during an EXTERNAL
ERROR.
In this case, the module will
attempt to restart normal
functioning after 5 minutes and
will repeat this procedure up to
five times.
Press the START/STOP button to
attempt to exit these conditions.
Please contact technical support
of the error persists.
E03
Definitive external
error
The definitive external error
condition is indicated after the
temporary error condition is
repeated 5 times.
Press the START/STOP button to
attempt to exit this condition.
Please contact technical support
of the error persists.
E04
Communication
error
This error condition occurs when
the control board cannot
communication with the power part.
This alarm condition closes the J3
contact on the power board for
possible external signals (alarm
light, siren, etc.).
Cut the power off and wait until
the LINE Led switches off and
after which turn power back on.
If the error condition occurs again,
contact your nearest assistance
centre.
E05
Over voltage error
This error occurs when the
current absorbed by the module is
greater than triple the nominal
current.
This condition can be caused
when the pump is blocked by
foreign bodies.
This alarm condition closes the J3
contact on the power board for
possible external signals (alarm
light, siren, etc.)
Cut off the power supply and wait
for the LINE Led to switch off.
Check the pump freely rotates
and if necessary remove foreign
bodies that block correct
functioning.
Turn power back on.
If the error persists, contact your
nearest assistance centre.
E06
Under voltage error
temporary
This error condition occurs when
the voltage is 10% less than the
nominal voltage (230V).
This alarm condition closes the J3
contact on the power board for
possible external signals (alarm
light, siren, etc.)
E07
Under voltage error
definitive
This error occurs when the
temporary under voltage condition
is repeated 5 times.
Press the button START/STOP or
cut the power off and wait until the
LINE Led switches off and after
which restart the system.
If the error occurs again, contact
your nearest assistance centre.
20 - GB -