INF S
Zero sensor
Minimum value read by the sensor (zero).
0,6 0
1
OFF P
Offset sensor
Use to enter an offset value for the pressure sensor.
0 0
10.0
SPE T
Switching off time Interval of time during which pressure must remain stable
(+/- 0.1 Bar) with a rotation lower than the average
switching off fre 10 to trigger the motor shutdown
cycle (seconds).
10 3
50
DIF P
Pressure
threshold
Subtract this figure from the set point to obtain pressure
when the motor is started-up. In other words, the motor
starts-up when pressure reaches the set point value
minus the threshold value (BAR).
0,3 0,1
0,5
ALL P
Water alarm
pressure
Indicates minimum system pressure, a lack of water alarm
will be generated under this threshold value Set to zero to
disable this function.
0,5 0
1
RIP 1
1st start-up
Waiting time between the first lack of water reading and
first attempt to automatically restart the system (minutes).
The module will not attempt to restart if this parameter is
set to zero.
1 0
1440
RIP 2
2nd restart
Waiting time between the first restart and the second
attempt to automatically restart the system (minutes).
5 0
1440
RIP 3
3rd restart
Waiting time between the second restart and the third
attempt to automatically restart the system (minutes).
60 0
1440
RIP 4
4th restart
Waiting time between the third restart and the fourth
attempt to automatically restart the system (minutes).
720 0
1440