1) THE PUMP IS NOT
RUNNING
1) No water.
2) Pump stalled.
3) No current.
4)
FLUSSCONTROLL*
is faulty.
1) Red LED light on (FAILURE)*. Identify the
cause, and then restart by pressing the
RESTART button.
2) Identify the cause and unblock the pump.
3) Check that power is present and that the
plug has been inserted properly. The Green
LED light (power On) is off*.
4) Contact the Customer Assistance Service.
2) THE PUMP DOES NOT
STOP
1) Inspect the pump and clean it if necessary.
2) See point 4.
3) Contact the Customer Assistance Service.
1) Reset button blocked.
2) The pump sucks air.
3)
FLUSSCONTROLL*
faulty.
GB
GB
5
3) THE ELECTROPUMP
DOES NOT PUMP WATER,
THE MOTOR DOES NOT RUN
4) THE MOTOR RUNS BUT
THE ELECTROPUMP DOES
NOT PUMP LIQUID
1) The pump is sucking air.
1) Check to ensure that joints are leak proof.
- check that liquid levels have not decreased
beneath the foot valve.
- Check to ensure that the foot valve is
unblocked and leak proof.
1) No power.
2) Motor protection tripped.
3) Defective condenser.
4) Shaft blocked.
5) THE ELECTROPUMP
STOPS AFTER RUNNING
FOR A SHORT PERIOD OF
TIME BECAUSE ONE OF THE
THERMAL MOTOR CIRCUIT
BREAKER TRIPS
1) Check that power is present and that the
plug has been inserted properly. The Green
LED light (power On) is off*.
2) Identify the cause, and then restart by
pressing the RESTART* button. Wait until
the system has cooled down if the
thermoregulator has intervened.
3) Contact the Customer Assistance Service.
4) Identify what caused the block:
a) make sure that the power supply
cable has been unplugged
b) remove the fan cover
c) Try to unblock the shaft by turning the
cooling fan.
Contact customer services if the problem
persits
1) The power supply does not comply
with the data on the nameplate.
2) A solid object is blocking the
impellers.
1) Check the voltage on the power supply
cable leads.
2) Contact customer services.
If the problem persists despite the recommended corrective actions, contact the Customer Assistance Service.
PROBLEM
POSSIBLE CAUSE
REMEDY
Ch. 7 Maintenance and troubleshooting
DANGER
Electric shock
risk
Make sure the machine is disconnected from electric power supply,
before performing maintenance operation.
In ordinary conditions,
NOCCHI
series electropumps do not require any maintenance. To prevent possible problems,
it is advisable to periodically check the pressure supplied and current absorption. A reduction of the pressure may
indicate that the electropump is worn. Sand and other corrosive materials present in the delivery fluid cause a rapid
wear and a reduction of performance. In this case, it is advisable to use a filter. An increase in current absorption
indicates the presence of abnormal mechanical friction in the pump and/or the motor.
If the electropump is not going to be used for a long period of time (i.e. one year), it is advisable to empty it completely (by
opening the drain cap, see Fig. 1 n. 10), rinse it with clean water and store it in a
dry location
, where it can be protected
f
rom frost.
* AUTOJET 60/50, AUTOJET 70/50, AUTOMAX 80/48, AUTOMAX 120/60