![Pentair Pool Products IntelliChlor CIC60P Installation And User Manual Download Page 8](http://html1.mh-extra.com/html/pentair-pool-products/intellichlor-cic60p/intellichlor-cic60p_installation-and-user-manual_1525912008.webp)
2
IntelliChlor Electronic Chlorine Generator Installation and User’s Guide
IntelliChlor Commercial System Components
An IntelliChlor Commercial System components can be configured as follows:
•
Stand-alone - No ORP:
This system consists of one CIC60P cell, one PC100 power center, and no
oxidation reduction potential (ORP) sensor/panel. Chlorine is dispensed on a timed basis, set by the
MORE and LESS buttons on the cell.
•
Stand-alone with ORP:
This system consists of one CIC60P cell, one CPC100 power center, and
an oxidation reduction potential (ORP) sensor/panel system (sold separately). The chlorine is
dispensed on demand from the ORP sensor.
•
Multi-Cell with ORP:
This system consists of one CIC60P cell and multiple secondary cells,
CIC60S, multiple power centers, and an oxidation reduction potential (ORP) sensor/panel system
(sold separately). The chlorine is dispensed on demand from the ORP sensor. For multiple cell
systems, there is one CIC60P cell, labeled PRIMARY and additional CIC60S cells labeled
SECONDARY. The SECONDARY cells communicate with the PRIMARY cell. Note: There can
only be one PRIMARY cell in a multiple cell system.
Acu-Trol panel with ORP sensor (sold separately)
The Acu-Trol panel contains an oxidation reduction potential (ORP) sensor that is placed in the water stream
to detect the amount of sanitizing ability in the water and according to a user-preset trip point, calls for chlorine
when low, and cancels chlorine when satisfied. This panel provides a dry-contact output that connects to the
IntelliChlor system. When the dry-contact terminals are closed, chlorine is required. When the dry contact
terminals are open, no chlorine is required. The Acu-Trol panel is not used for a stand-alone-No ORP system.
PC100 Commercial Power Center - No ORP
The PC100 commercial power center provides power to one CIC60P cell, but does not interconnect to an
ORP system. The CIC60P cell will operate on a timed basis, set by the MORE and LESS buttons on the cell.
This system may be used with a time clock to control operations.
CPC100 Commercial Power Center with ORP
The CPC100 commercial power center, with ORP provides power to each cell. The power center labeled
PRIMARY contains the dry-contact wires that connect to the external ORP system. When the dry-contact
wires are closed, the “Primary” panel sends a 100% command to the cell; chlorine is being produced. When
the dry-contact wires are opened, the Primary panel sends a 0% output command to the cell, to stop producing
chlorine.
Example 1:
Small hotel pool requires a two (2) lb. system.
Equipment used:
One CIC60P cell
One CPC100 power center (one power center)
Acu-Trol panel with ORP sensor
Example 2:
Health club spa requires a four (4) lb. system
Equipment used:
Use multiple-cell system COMSYS-4
Sizing:
To correctly size the chlorine requirements of a commercial pool, use the following rule:
•
Two (2) lbs. of chlorine per 10,000 gallons of water
To size a commercial spa, use this general rule:
•
One pound of chlorine per 2,000 gallons of water
These rules appear oversized, but ensure rapid chlorine make-up time, essential for commercial health codes.
Summary of Contents for IntelliChlor CIC60P
Page 22: ...16 IntelliChlor Electronic Chlorine Generator Installation and User s Guide Blank Page ...
Page 26: ...20 IntelliChlor Electronic Chlorine Generator Installation and User s Guide Blank Page ...
Page 30: ...24 IntelliChlor Electronic Chlorine Generator Installation and User s Guide Blank Page ...
Page 34: ...28 IntelliChlor Electronic Chlorine Generator Installation and User s Guide Blank Page ...