![Pentair Pool Products IntelliChlor CIC60P Installation And User Manual Download Page 12](http://html1.mh-extra.com/html/pentair-pool-products/intellichlor-cic60p/intellichlor-cic60p_installation-and-user-manual_1525912012.webp)
6
IntelliChlor Electronic Chlorine Generator Installation and User’s Guide
NOT TO SCALE
Note:
For best flow
sensing, provide at
least 12"-18" of straight
pipe in front of the cell
inlet.
IntelliChlor Plumbing Diagram (For single CIC60P cell system)
Plumbing the IntelliChlor Electronic Chlorine Generator (IECG) for a single CIC60P cell system:
• Always install the IntelliChlor Electronic Chlorine Generator AFTER the filter and heater (see
“System Diagram” on page 4). The ICEG should be no closer than three (3) feet away from the
heater outlet.
• If the IECG is installed on a pool/spa combination system, install (see diagram below) the IECG
BEFORE the pool/spa return valve to allow proper chlorination of both the pool and spa and also to
avoid creating gas traps in the pipes.
Note: If a multiple cell system is used, refer to the Installation guide for that system. The kit comes with
prepared plumbing manifolds.
Loop Plumbing Diagram (For single CIC60 cell system)
The IntelliChlor Electronic Chlorine Generator is designed to operate with water flow rates from 25 gallons per
minute (gpm) up to 105 gpm. Do not exceed 105 gpm or pipe manufacturers recommended flow rate,
whichever is less. For flow rates over 80 gpm, it is recommend that you use a bypass loop (as shown below)
for best chlorine production. Installations with flow rates over 80 gallons per minute are those that have
in-floor cleaning systems or booster pumps. These single CIC60 cell systems should use a bypass loop with the
IECG with a flow control valve that assures that the flow through the IECG is maintained within its designed
operating water flow rates.
Note: Single CIC60 cell system. NOT FOR MULTIPLE CELL SYSTEMS.
NOT TO SCALE
F lo w c o n tro l v a lve
Bypass loop
IN
TE
LL
IC
H
LO
R
EL
EC
TR
O
N
IC
C
H
LO
RI
N
E
G
EN
ER
A
TO
R
VALVE
FLOW IN
FLOW OUT
FLOW IN
FLOW OUT
“UPWARD FLOW”
Summary of Contents for IntelliChlor CIC60P
Page 22: ...16 IntelliChlor Electronic Chlorine Generator Installation and User s Guide Blank Page ...
Page 26: ...20 IntelliChlor Electronic Chlorine Generator Installation and User s Guide Blank Page ...
Page 30: ...24 IntelliChlor Electronic Chlorine Generator Installation and User s Guide Blank Page ...
Page 34: ...28 IntelliChlor Electronic Chlorine Generator Installation and User s Guide Blank Page ...